background image

1.0 General

The 3M brand Fibrlok

TM

 Optical Fiber Splicing System

provides permanent mechanical splices for single or multi
mode fiber having 125 µm diameter cladding.  Three color
coded versions of the Fibrlok Splice are available for splicing
250 µm and 900 µm diameter plastic coated fiber.

1.01 Fibrlok Optical Fiber Splice

Jacket

Cap

Fiber Entry Port

(each end)

Fiber Size Designation Circles

(1/4 circle for 250 µm coating,

full circle for 900 µm coated fiber)

End Plug

(each end)

The Fibrlok 2599 Splice is for splicing 900 µm fiber to 900

µm fiber:

The Fibrlok 2590 Splice is for splicing 250 µm fiber to 900

µm fiber:

The Fibrlok 2525 Splice is for splicing 250 µm fiber to 250

µm fiber:

Содержание Fibrlok 2525

Страница 1: ...Instructions Issue 6 August 1991 Fibrlok Optical Fiber Splicing System TM...

Страница 2: ...cing 250 m and 900 m diameter plastic coated fiber 1 01 Fibrlok Optical Fiber Splice Jacket Cap Fiber Entry Port each end Fiber Size Designation Circles 1 4 circle for 250 m coating full circle for 90...

Страница 3: ...m Splice Holding Cradle Finger Cutout Base Fiber Cleave Length Gauge both ends of tool Pivoted Handle shown open Toggle Arm Fiber Retention Pad Fiber Alignment Guides 2 Fiber Retention Pad Instruction...

Страница 4: ...zation and splice storage 2 04 Remove Fibrlok splice from protective package Load the splice into the assembly tool by pressing firmly at the ends of the splice Note Carefully follow health and safety...

Страница 5: ...Cleave Length for End of Splice with Black Plug Symbol Fibrlok Splice Designation 3M Fibrlok 2525 250 m x 250 m 3M Fibrlok 2590 250 m x 900 m 3M Fibrlok 2599 900 m x 900 m 14 0 mm 0 5 mm 551 in 020 in...

Страница 6: ...nto the splice immediately following cleaning and placing in retention pad to minimize exposure to the atmosphere and reduce the risk of contamination Note Push fiber straight into fiber alignment gui...

Страница 7: ...n it had initially 4 07 Push the first fiber back against the second fiber until there are equal bows in both fibers Note Do not pull on either of the fibers following establishment of the bows in the...

Страница 8: ...plice refabrication will require a length of 2 inches on each fiber DO NOT REUSE FIBRLOK SPLICES 5 0 Fiber Organization and Splice Storage When storing fiber slack in a splice tray the spliced fiber e...

Страница 9: ...lice holder or tray whenever possible 5 04 Remove the minimum amount of fiber required for fiber preparation and splicing Remove less than one loop if possible 5 05 Prepare fibers and complete splice...

Страница 10: ...ventional camera type tripods and other standard telco splicing rig components The 2505 Mounting Adapter provides the ability to mount the Fibrlok Assembly Tool on a variety of surfaces and in any ori...

Страница 11: ...100 pkg Magnifier Cleaved Fiber Inspection Coaxial Cable Stripper Instruction Manual 6 03 3M Fiber Preparation Kits provide all the tools necessary for the assembly of the Fibrlok Splice Fiber Splice...

Страница 12: ...the Seller which are not contained in the Seller s current publications shall have no force or effect unless contained in an agreement signed by an authorized officer of the Seller The statements cont...