manualshive.com logo in svg
background image

3M and Dynatel are trademarks of 3M Company. 

Important Notice

All statements, technical information, and recommendations 
related to 3M’s products are based on information believed 
to be reliable, but the accuracy or completeness is not 
guaranteed.

 

Before using this product, you must evaluate it 

and determine if it is suitable for your intended application.

 

You assume all risks and liability associated with such 
use.

 

Any statements related to the product which are not 

contained in 3M’s current publications, or any contrary 
statements contained on your purchase order shall have no 
force or effect unless expressly agreed upon, in writing, by 
an authorized officer of 3M.

Warranty; Limited Remedy; Limited Liability. 

This product will be free from defects in material and 
manufacture for a period of one (1) year from the time 
of purchase.

 

3M MAKES NO OTHER WARRANTIES 

INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED 
WARRANTY OF MERCHANTABILITY OR FITNESS FOR A 
PARTICULAR PURPOSE.

 

If this product is defective within 

the warranty period stated above, your exclusive remedy 
shall be, at 3M’s option, to replace or repair the 3M product 
or refund the purchase price of the 3M product.

 

Except 

where prohibited by law, 3M will not be liable for any 
indirect, special, incidental or consequential loss or 
damage arising from this 3M product, regardless of 
the legal theory asserted. 

3

Track and Trace Solutions

6801 River Place Blvd.

Austin, TX 78726-9000

http://www.3M.com/dynatel

Please Recycle. Printed in USA.

© 3M 2010. All Rights Reserved.

78-9000-0303-5-A

Troubleshooting

1.  If you can’t get a good signal on a cable, what can you try?

 

a. Are the batteries in the Transmitter and Receiver OK?

 

b. Are the facilities unbonded/isolated?

 

c.  Be sure that the RED and BLACK Leads are plugged in 

completely.

 

d. Be sure that the RED and BLACK Leads are not broken.

 

e. Is the ground rod in the dirt far enough?

 

f.  Is the resistance value measured in Ohms mode on the 

Transmitter very high? Try moving the ground rod location, 
pour some water around it, use a shovel as the ground rod.

 

g.  Verify that the Receiver frequency matches the Transmitter 

frequency.

 

h.  Verify that RED Lead is connected directly to the sheath of 

the cable.

2.  OK, I’ve done that, now what?

 

a.  Put everything in the closure back to it’s original condition or 

better.

 

b.  Go to the other end of the facility, unbond and then connect 

to the facility.

 

c. Choose the lowest frequency and check for a signal.

3.  Still not a good signal, what next?

 

a. Keep the Transmitter hooked to the facility.

 

b.  Go to the other end of the facility and isolate it from all other 

facilities.

 

c. Use an “extension lead” and ground the target facility.

 

d.  Go back to the Transmitter and check for continuity (Ohm-

meter mode). If there is continuity, press the Trace key on the 
Transmitter and choose the lowest frequency.

 

e.  If there is not continuity, go back to the other end of the 

facility and insure the correct cable is isolated/grounded.

4.   Still not getting a good signal!!

 

a.  Choose the second lowest frequency available and begin the 

process again.

Depth & Relative Current

19. To determine depth, place the Receiver tip on the ground 

over the cable path and press the Depth key. Choose 
between 1-Shot or Live depth by pressing the first soft 
(yellow) key from the left when in the Depth display.

Note: In order to measure the depth and relative current 
accurately, the target must be pinpointed and the Receiver 
handle should be in-line with the target path.

20. Relative current is displayed when the depth is 

measured. The relative current value will be much closer 
to the relative current that is alternately flashing with the 
frequency value on the Transmitter than adjacent cables 
that are detected by the Receiver.

Отзывы: