Red light is flashing on carabiner once every 3 seconds. 

(This means the battery is low on the carabiner.)

1.  Follow procedure in section 4.2 for carabiner battery replacement. 

  

� 

Be careful to not pull battery holder off circuit board.

2.  Red Tag for OP Manufacturer 

  

� 

OP Manufacturer—Call 3M to discuss if carabiner has hardware fault.

SRL web showing premature wear due to twisting.

1.   Reference the SRL Instructions for Use manual for inspection requirements to see if SRL should 

be taken out of service.

2.  Always make sure to let SRL web hang loose and untwist after each use.
3.  Do not store SRL web twisted.

Long, continuous red flashes on carabiner LED. 

(This means there is a hardware fault in the carabiner.)

1.  Red Tag for OP Manufacturer 

  

� 

OP Manufacturer—Call 3M to describe situation and confirm if carabiner needs to be replaced.

Bluetooth is a trademark of Bluetooth 

SIG, Inc. 3M, DBI-SALA and Nano-

Lok are trademarks of 3M Company 

and its affiliates.  

© 3M 2021. All rights reserved.

70-0717-6115-2

3M Fall Protection
3833 SALA Way 
Red Wing, MN 55066 USA

Phone 800.328.6146
Email [email protected]
Web 3M.com/FallProtection
IFU 

 multimedia.3m.com/mws/media/1752030O/3m-dbi-sala-nano-lok-

connected-order-picker-srd-system-user-instructions.pdf

Содержание DBI-SALA Nano-Lok Connected Order Picker SRL...

Страница 1: ...ual and Troubleshooting Guide This training manual provides visuals and troubleshooting flow paths for the 3M DBI SALA Nano Lok Connected Order Picker SRL System This guide does not replace the Instru...

Страница 2: ...shooting process flows It is to be used as a supplement to the Instruction for Use document For technical assistance contact 3M Fall Protection at 800 328 6146 3M DBI SALA Nano Lok Connected Order Pic...

Страница 3: ...3 1 System Overview Raymond OP Alert Box 8548924 LED Light Strips 9515033 Alert Box Power Cable 9515475...

Страница 4: ...4 Hyster Yale OP Connected Order Picker Self Retracting Lifeline 2000037 Alert Box 8548924 Cab Mount Bracket 3100084 Dual Sensing Connected Hook LED Light Strips 9515033 Alert Box Power Cable 9515475...

Страница 5: ...5 Crown OP Alert Box 8548924 Cab Mount Bracket 3100084 LED Light Strips 9515033 Alert Box Power Cable 9515475 Connected Order Picker Self Retracting Lifeline 2000037 Dual Sensing Connected Hook...

Страница 6: ...6 Jungheinrich OP Alert Box 8548924 Cab Mount Bracket 3100084 LED Light Strips 9515033 Alert Box Power Cable 9515475 Connected Order Picker Self Retracting Lifeline 2000037 Dual Sensing Connected Hook...

Страница 7: ...Lok Cab Mount Bracket 3100084 3M DBI SALA Nano Lok Alert Box 8548924 3M DBI SALA Nano Lok Alert Box Power Cable 9515475 3M DBI SALA Nano Lok LED Light Strips 9515033 3M Supplied Cable Ties Parts to ha...

Страница 8: ...8 3 Video Demonstration Training A System Overview B System Verification Check C Bluetooth Pairing Process D Battery Replacement E Tie Off Alert Escalation...

Страница 9: ...ver using a flat edge if needed and flip open the black plastic cover to reveal the battery and battery holder 3 Carefully insert a flat edge under the battery and pry it out of the holder being caref...

Страница 10: ...LED strips are plugged in No the power connector looks normal and undamaged Reset the carabiner baseline Twist the carabiner gate 5 6 times and look for a green flashing light Look for momentary gree...

Страница 11: ...closed Wipe the lens on the sensor box with a microfiber cloth or compressed air can No nothing stuck No nothing in the motion zone waist up of OP out to sides of platform Yes RED TAG Didn t work RED...

Страница 12: ...battery completely dead Replace the battery per section 4 2 Yes problem resolved Didn t work Yes battery was dead Problem resolved Yes RED TAG Yes RED TAG LED lights are red with yellow tips on the e...

Страница 13: ...r off the circuit board RED TAG Didn t work RED TAG Yes problem solved The LED lights are flashing yellow Is there an obstruction or debris blocking the sensor box lens Pull the power cord on sensor b...

Страница 14: ...ll 3M if fuse is not blown The LED lights remain red when I tie off This means the carabiner is not relaying it s tied off to the sensor box 1 Is there something stuck in the gate e g hood hair etc th...

Страница 15: ...ttery frequently more than once per month there may be something keeping the carabiner gate open call 3M to discuss 2 Red Tag for OP Manufacturer if above actions do not work OP Manufacturer Call 3M f...

Страница 16: ...let SRL web hang loose and untwist after each use 3 Do not store SRL web twisted Long continuous red flashes on carabiner LED This means there is a hardware fault in the carabiner 1 Red Tag for OP Ma...

Отзывы: