3M DBI SALA LAD-SAF 5000335 Скачать руководство пользователя страница 12

12

4.0 USE

4.1  BEFORE EACH USE:

  Verify that your work area and Fall Protection system meet all criteria defined in these instructions. 

Verify that a formal Rescue Plan is in place. Inspect the product per the ‘User’ inspection points defined in the “Inspection 

and Maintenance Log”. If inspection reveals an unsafe or defective condition, or if there is any doubt about its condition 

for safe use, remove the product from service immediately. Clearly tag the product “DO NOT USE”. See Section 5 for more 

information.

4.2  AFTER A FALL:

 If this equipment is subjected to fall arrest or impact force, remove it from service immediately. Clearly 

tag it “DO NOT USE”. See Section 5 for more information.

4.3 

POSITIONING:

 It may be necessary to move your lifeline subsystem along its vertical lifeline during use. When moving 

your lifeline subsystem, always tow the lifeline subsystem by its secured lanyard. To move your lifeline subsystem along 

the vertical lifeline after install:
1.  Pull up slightly on the rope grab’s secured lanyard to release the rope grab from its settled position. If necessary, lift 

the connection handle as well.

 

;

It is recommended that the rope grab be positioned at or above D-ring level to reduce possible free fall.

2.  Tow the rope grab by its secured lifeline into the position you would like to move it.
3.  After the rope grab has been moved, lock it into position by pulling the connection handle back into its “DOWN” 

position. Verify that the rope grab is secure after releasing it by pulling down on the lanyard slightly.

4.4  SYSTEM APPLICATIONS:

 See Figure 10 for reference. Lifeline subsystems may be used for Fall Arrest (10.1) or 

Restraint (10.2) applications. Any Fall Protection system with a lifeline subsystem should also include a Full Body Harness 

(A), an Energy-Absorbing Lanyard (B), a Vertical Lifeline (C), and a Counterweight (D) on the Vertical Lifeline.

Figure 10 - System Applications

10.1

10.2

C

A

B

D

C

A

B

D

4.5  USE WITH A VERTICAL LIFELINE:

 There are some additional precautions that must be taken when using this product 

with a vertical lifeline. When using a vertical lifeline:
•  Tension the lifeline to ensure smooth operation of the rope grab along the lifeline.
• 

Under certain conditions determined by a Qualified Person, such as working on a moving platform, it is allowable to let 

the vertical lifeline follow the worker as they move. In these situations, the lanyard should be kept as short as possible 

and never exceed the length requirements specified in Figure 1 and Table 1.

•  Always verify that your vertical lifeline is long enough for your application. Never install the system in a manner where 

the lifeline subsystem could become detached by sliding off the bottom of the lifeline.

•  Never tie your vertical lifeline into a knot to limit movement of the lifeline subsystem.

Содержание DBI SALA LAD-SAF 5000335

Страница 1: ...rmation See Table 1 for more information about compatible lanyard models Figure 1 Product Overview Style Model ANSI OSHA Product Weight Lanyard Length Compatible Lanyard Models A 5000335 1 7 lb 0 77 kg 2 5 ft 0 76 m 1246535 1246090 3 0 ft 0 91 m 1246536 1246012 5009079 3 0 lb 1 36 kg See Table 1 Integral only 5009080 3 0 lb 1 36 kg See Table 1 Integral only A 3MTM LAD SAFTM Mobile Rope Grab ...

Страница 2: ...e Only use the connecting device to attach and detach from the system Follow all manufacturer recommendations when connecting a lifeline Use caution when installing using or moving the product as moving parts may create pinch points Always maintain three points of contact while climbing Only use the connection points of your harness approved in these instructions to attach an approved connector to...

Страница 3: ...applications The lifeline subsystem is comprised of a Handle Spring A that contacts the Lanyard Connection Handle C The Enclosure D makes up the body of the rope grab The Hinged Rope Retainer E is locked in the closed position around a vertical lifeline using a removable Detent Pin B The Locking Roller F and Roller Cam H are designed to lock on the vertical lifeline in the event of a fall The Grav...

Страница 4: ...r non certified anchorages or 2 Two times the forseeable force for certified anchorages When more than one Restraint system is attached to an anchorage the strengths set forth in 1 and 2 above shall be multiplied by the number of systems attached to the anchorage Certified anchorages must be certified by a Qualified Person as meeting the criteria for a certified anchorage as specified in these ins...

Страница 5: ...ning 3 4 in 19 mm gate strength 3 600 lbf 16 kN Energy Absorber Tear web polyester webbing and nylon cover Maximum Free Fall 6 ft 1 83 m Arresting Force Average 900 lbf 4 kN Maximum 1 800 lbf 8 kN Lanyard Compatibility Lifeline Subsystem Model Compatible Lanyards 5000335 Use an energy absorbing lanyard that meets ANSI Z359 13 requirements Do not use a restraint lanyard For ANSI lanyard length must...

Страница 6: ...in Table 1 2 2 CAPACITY The user capacity of a complete Fall Protection system is limited by its lowest rated maximum capacity component For example if your connecting subsystem has a capacity that is less than your harness you must comply with the capacity requirements of your connecting subsystem See the manufacturer instructions for each component of your system for capacity requirements 2 3 EN...

Страница 7: ...lbf or greater C In a false engagement where size or shape of the connector or connecting element is not compatible and without visual confirmation would seem to be fully engaged D To each other E Directly to webbing or rope lanyard or tie back material unless the instruction manuals for both the lanyard and connector specifically allow such a connection F To any object whose size or shape does no...

Страница 8: ...y fall A user s Required Fall Clearance FC is the sum of Free Fall FF Deceleration Distance DD Harness Stretch HS and a Safety Factor SF See Figure 6 1 for reference Free Fall FF is the distance the user travels before deployment of the energy absorber when the lanyard fully extends Deceleration Distance DD is the distance the user falls measured from activation of the deceleration device until st...

Страница 9: ...9 See Fall Clearance Charts for fall clearance requirements specific to your product Figure 6 Fall Clearance Overview 6 1 6 2 6 3 FF DD HS SF FC FC FF DD HS SF E W FC ...

Страница 10: ...C 0 ft 0 m 16 ft 4 88 m 10 ft 3 0 m 17 ft 5 18 m 25 ft 7 6 m 18 5 ft 5 64 m 50 ft 15 2 m 21 ft 6 40 m 75 ft 22 9 m 23 5 ft 7 16 m 100 ft 30 5 m 26 ft 7 92 m 150 ft 45 7 m 31 ft 9 45 m 200 ft 61 0 m 36 ft 10 97 m 250 ft 76 2 m 41 ft 12 50 m 300 ft 91 4 m 46 ft 14 02 m AP FC TIP FREQUENT ADJUSTMENTS In some work situations it may be necessary to frequently adjust your lifeline subsystem To avoid hav...

Страница 11: ...ified in Figure 1 and Table 1 4 Test the operation of the rope grab by pulling down on the attached lanyard Once the locking roller has fully engaged the lifeline the rope grab should not be able to move down any further Figure 7 Connecting to Anchorage A B C D A D B C 3 5 SECURING A CONNECTING SUBSYSTEM Only energy absorbing lanyards may be used with lifeline subsystems See Figure 8 for reference...

Страница 12: ... like to move it 3 After the rope grab has been moved lock it into position by pulling the connection handle back into its DOWN position Verify that the rope grab is secure after releasing it by pulling down on the lanyard slightly 4 4 SYSTEM APPLICATIONS See Figure 10 for reference Lifeline subsystems may be used for Fall Arrest 10 1 or Restraint 10 2 applications Any Fall Protection system with ...

Страница 13: ...condition or because the product has been exposed to fall arrest or impact force then the product must be destroyed 5 4 PRODUCT LIFE The functional life of the product is determined by work conditions and maintenance As long as the product passes inspection criteria it may remain in service 6 0 MAINTENANCE SERVICE AND STORAGE Equipment that is in need of maintenance or scheduled for maintenance sh...

Страница 14: ...hensive list of terms and definitions please visit our website www 3m com FallProtection ifu glossary AUTHORIZED PERSON A person assigned by the employer to perform duties at a location where the person will be exposed to a fall hazard COMPETENT PERSON One who is capable of identifying existing and predictable hazards in the surroundings or working conditions which are unsanitary hazardous or dang...

Страница 15: ...15 Figure 11 RFID Tag Location A A Figure 12 Product Labels A C B D A 2 1 B 1 2 3 4 5 C 1 2 D 1 ...

Страница 16: ...ed Rope Retainer E from closing when the rope grab is upside down Inspect the auto locking function of the rope grab by installing the rope grab on the vertical lifeline With the Lanyard Connection Handle in the up position release the Connection Handle and the rope grab and allow the rope grab to free fall on the lifeline The Locking Roller F should quickly lock and stop the rope grab Lanyard Web...

Страница 17: ...17 Figure 13 Webbing Figure 14 Energy Absorber Figure 15 Connectors D C B A B A A A B ...

Страница 18: ......

Страница 19: ......

Страница 20: ... mmm com Japan 3M Japan Ltd 6 7 29 Kitashinagawa Shinagawa ku Tokyo Phone 81 570 011 321 Fax 81 3 6409 5818 psd jp mmm com WEBSITE 3M com FallProtection FM534873 9 0 0 1 I S O DECLARATION OF CONFORMITY 3M com FallProtection DOC European Union and United Kingdom GLOBAL PRODUCT WARRANTY LIMITED REMEDY AND LIMITATION OF LIABILITY WARRANTY THE FOLLOWING IS MADE IN LIEU OF ALL WARRANTIES OR CONDITIONS ...