background image

FORM NO: 5908278  REV: A

9

SAFETY INFORMATION

Please read, understand, and follow all safety information contained in these instructions prior to the use of this Flexiguard System. 

FAILURE TO DO SO COULD RESULT IN SERIOUS INJURY OR DEATH.

These instructions must be provided to the user of this equipment. Retain these instructions for future reference.

Intended Use:

This Flexiguard System is intended for use as part of a complete fall protection or rescue system.

Use in any other application including, but not limited to, material handling, recreational or sports related activities, or other activities not described in 

the User Instructions, is not approved by 3M and could result in serious injury or death.

This system is only to be used by trained users in workplace applications.

 

!

WARNING

This Flexiguard System is part of a personal fall protection or rescue system. It is expected that all users be fully trained in the safe installation and 

operation of the complete system. 

Misuse of this system could result in serious injury or death.

 For proper selection, operation, installation, 

maintenance, and service, refer to all Product Instructions and all manufacturer recommendations, see your supervisor, or contact 3M Technical Service.

• 

To reduce the risks associated with transporting a Flexiguard system which, if not avoided, could result in serious injury or death:

 

-

Ensure the system is properly secured or configured prior to transport. Refer to the User Instructions for detailed transportation requirements.

 

-

Only transport below 5 mph (8 km/h) and at inclines of 10° or less, or as outlined in the User Instructions.

 

-

Ensure the system will not contact overhead objects or electrical hazards while transporting or in use.

• 

To reduce the risks associated with working with a Flexiguard system which, if not avoided, could result in serious injury or death:

 

-

Inspect all components of the system before each use, at least annually, and after any fall event, in accordance with the User Instructions.

 

-

If inspection reveals an unsafe or defective condition, remove the system from service and repair or replace according to the User Instructions.

 

-

Any system that has been subject to fall arrest or impact force must be immediately removed from service. Refer to the User Instructions or 

contact 3M Fall Protection.

 

-

The substrate or structure on which the system is attached/positioned must be able to sustain the static loads specified for the system in the 

orientations permitted in the User Instructions or Installation Instructions.

 

-

Do not exceed the number of allowable users as per the User Instructions.

 

-

Never attach to a system until it is fully assembled, positioned, adjusted, and installed. Do not adjust the system while a user is attached.

 

-

Never work outside the safe work area as defined by the User Instructions.

 

-

Do not connect to the system while it is being transported or installed.

 

-

Always maintain 100% tie-off when transferring between anchor points on the system.

 

-

Use caution when installing, using, and moving the system as moving parts may create potential pinch points.

 

-

Ensure proper lockout/tagout procedures have been followed when applicable.

 

-

Only connect fall protection subsystems to the designated anchorage connection point on the system.

 

-

When drilling holes for assembly or installation of the system, ensure no electric lines, gas lines, or other critical materials or equipment will be 

contacted by the drill.

 

-

Ensure that fall protection systems/subsystems assembled from components made by different manufacturers are compatible and meet the 

requirements of applicable standards, including the ANSI Z359 or other applicable fall protection codes, standards, or requirements. Always 

consult a Competent or Qualified Person before using these systems.

• 

To reduce the risks associated with working at heights which, if not avoided, could result in serious injury or death:

 

-

Ensure your health and physical condition allow you to safely withstand all of the forces associated with working at height. Consult with your 

doctor if you have any questions regarding your ability to use this equipment.

 

-

Never exceed allowable capacity of your fall protection equipment.

 

-

Never exceed maximum free fall distance of your fall protection equipment.

 

-

Do not use any fall protection equipment that fails pre-use or other scheduled inspections, or if you have concerns about the use or suitability 

of the equipment for your application. Contact 3M Technical Services with any questions.

 

-

Some subsystem and component combinations may interfere with the operation of this equipment. Only use compatible connections. Consult 

3M prior to using this equipment in combination with components or subsystems other than those described in the User Instructions.

 

-

Use extra precautions when working around moving machinery (e.g. top drive of oil rigs) electrical hazards, extreme temperatures, chemical 

hazards, explosive or toxic gases, sharp edges, or below overhead materials that could fall onto you or the fall protection equipment.

 

-

Use Arc Flash or Hot Works devices when working in high heat environments.

 

-

Avoid surfaces and objects that can damage the user or equipment.

 

-

Ensure there is adequate fall clearance when working at height.

 

-

Never modify or alter your fall protection equipment. Only 3M or parties authorized in by 3M may make repairs to the equipment.

 

-

Prior to use of fall protection equipment, ensure a rescue plan is in place which allows for prompt rescue if a fall incident occurs.

 

-

If a fall incident occurs, immediately seek medical attention for the fallen worker for the worker who has fallen.

 

-

Do not use a body belt for fall arrest applications. Use only a Full Body Harness. 

 

-

Minimize swing falls by working as directly below the anchorage point as possible.

 

-

If training with this device, a secondary fall protection system must be utilized in a manner that does not expose the trainee to an unintended 

fall hazard.

 

-

Always wear appropriate personal protective equipment when installing, using, or inspecting the device/system.

EN

Содержание DBI SALA FlexiGuard SafRig

Страница 1: ...15 ft 457 2 cm 15 ft 155 cm 61 in A B C B A 8560013 8545764 8545755 8560015 8560016 601 kg 1 325 lb 2 703 kg 5 960 lb 8560013 8545764 590 kg 1 300 lb EN795 2012 Type B CE Type Test No 2797 BSI The Netherlands B V Say Building John M Keynesplein 9 1066 EP Amsterdam Netherlands CE Product Quality Control No 2797 BSI The Netherlands B V Say Building John M Keynesplein 9 1066 EP Amsterdam Netherlands ...

Страница 2: ...2 2 B A E F G G H G G F C I I I I K K K J J J D L L L L N M O ...

Страница 3: ... 4 11 4 3 5 11 7 3 6 12 1 3 7 12 5 3 8 12 3 7 12 0 3 7 12 0 3 7 12 2 3 7 12 4 3 8 12 6 3 9 13 0 4 0 13 4 4 1 13 4 0 13 0 4 0 13 0 4 0 13 2 4 0 13 3 4 1 13 6 4 1 13 9 4 2 14 3 4 4 14 4 3 14 0 4 3 14 0 4 3 14 1 4 3 14 3 4 4 14 6 4 4 14 9 4 5 15 2 4 6 15 4 6 15 0 4 6 15 0 4 6 15 1 4 6 15 3 4 7 15 5 4 7 15 8 4 8 16 2 4 9 16 4 9 16 0 4 9 16 0 4 9 16 1 4 9 16 3 5 0 16 5 5 0 16 8 5 1 17 1 5 2 17 5 2 17 0...

Страница 4: ...4 7 1 2A 2B 3B 8 1 2 3 3A ...

Страница 5: ...5 9 1 2 3 1 4 Ï ÏóÏ A B A B ...

Страница 6: ...6 10 A A ...

Страница 7: ...7 11 B B 1 2 3 4 5 F 1 2 4 3 C 1 2 E 1 9509784 REV A APPROXIMATE WEIGHT 6000 lbs 2 722 kg WARNING D 1 A 1 2 3 A B F C B D D D E ...

Страница 8: ...8 ...

Страница 9: ...ff when transferring between anchor points on the system Use caution when installing using and moving the system as moving parts may create potential pinch points Ensure proper lockout tagout procedures have been followed when applicable Only connect fall protection subsystems to the designated anchorage connection point on the system When drilling holes for assembly or installation of the system ...

Страница 10: ...oint H The Counterweight Base has Lifting Channels I and Lifting Eyes J for transport with a Forklift Pallet Jack Crane etc and Slope Indicators K to ensure the system is level Optional Leveling Jacks L can be installed on Jack Brackets on the Couterweight Base Table 1 Specifications System Specifications Capacity 1 Person with a combined weight including clothing tools etc of no more than 140 kg ...

Страница 11: ...RD 6 kN 1 350 lbf 2 3 FALL PATH AND SRD LOCKING SPEED A clear path is required to assure positive locking of an SRD Situations which do not allow for an unobstructed fall path should be avoided Working in confined or cramped spaces may not allow the body to reach sufficient speed to cause the SRD to lock if a fall occurs Working on slowly shifting material such as sand or grain may not allow enoug...

Страница 12: ...ONS Snap hooks and carabiners used with this equipment must be self locking Ensure all connections are compatible in size shape and strength Do not use equipment that is not compatible Ensure all connectors are fully closed and locked 3M connectors snap hooks and carabiners are designed to be used only as specified in each product s user s instructions See Figure 6 for examples of inappropriate co...

Страница 13: ...Ball on the Hitch Ball Post 2 Position the Vertical Mast over the Base Lift the assembled Vertical Mast with a Lifting Sling and Forklift or Crane Position the Vertical Mast so the Mounting Socket in the bottom of the Vertical Mast is directly over the Hitch Ball Post 3 Lower the Vertical Mast onto the Base Lower the Vertical Mast onto the Base until the Hitch Ball fully seats in the Vertical Mast...

Страница 14: ...uencies and procedures defined in the manufacturer s instructions Record the inspection date on the inspected equipment Record the inspection date and results on the Inspection and Maintenance Log at the back of this manual 5 2 DEFECTS If inspection reveals an unsafe or defective condition or if any doubt should arise as to its condition for safe use remove the SafRig FAS from service immediately ...

Страница 15: ...on For more information please visit our website http www 3M com FallProtection RFID 8 0 LABELS Figure 11 illustrates labels on the SafRig FAS Labels must be replaced if they are not fully legible Information provided on each label is as follows A 1 Notified Body 2 Applicable Standard 3 Read all instructions B 1 Serial Number 2 Manufactured Year Month 3 Lot Number 4 Model Number 5 Length ft C 1 Wa...

Страница 16: ...d SafRig Fall Arrest System should be installed and inspected per the manufacturer s instructions Serial Number s Date Purchased Model Number Date of First Use Corrective Action Maintenance Approved By Next inspection due Date Corrective Action Maintenance Approved By Next inspection due Date Corrective Action Maintenance Approved By Next inspection due Date Corrective Action Maintenance Approved ...

Страница 17: ...dquarters Le Broc Center Z I 1re Avenue BP15 06511 Carros Le Broc Cedex France Phone 33 04 97 10 00 10 Fax 33 04 93 08 79 70 informationfallprotection mmm com Australia New Zealand 137 McCredie Road Guildford Sydney NSW 2161 Australia Toll Free 1800 245 002 AUS Toll Free 0800 212 505 NZ 3msafetyaucs mmm com Asia Singapore 1 Yishun Avenue 7 Singapore 768923 Phone 65 6450 8888 Fax 65 6552 2113 Total...

Отзывы: