3M Breathe Easy Turbo Скачать руководство пользователя страница 5

 

 

Inspection and Record Keeping Breath Easy Turbo PAPR 

Date 

Inspected 

PAPR ID  

(CE #) 

Turbo Unit 

Checked 

Breathing 

Tube 

Checked 

Airflow Rate 

cfm 

Comments Initials 

 

 

 

 
 

 

 

 

 

 

 

 
 

 

 

 

 

 

 

 
 

 

 

 

 

 

 

 
 

 

 

 

 

 

 

 
 

 

 

 

 

 

 

 
 

 

 

 

 

 

 

 
 

 

 

 

 

 

 

 
 

 

 

 

 

 

 

 
 

 

 

 

 

 

 

 
 

 

 

 

 

 

 

 
 

 

 

 

 

 

 

 
 

 

 

 

 

 

 

 
 

 

 

 

 

 

 

 
 

 

 

 

 

 

 

 
 

 

 

 

 

 

 

 
 

 

 

 

 

 

 

 
 

 

 

 

 

 

 

 
 

 

 

 

 

 

 

 
 

 

 

 

 

 

 

 
 

 

 

 

 

 

 

 
 

 

 

 

 

Page 5 of 5; 3M Breathe Easy Turbo PAPR; 6/15/06 

Содержание Breathe Easy Turbo

Страница 1: ...er until it snaps into place if the head cover is not already connected Reconnect the respirator headpiece breathing tube assembly to Turbo unit and verify that air is flowing before donning the respirator headpiece DONNING RESPIRATOR 1 Ensure that one end of breathing tube is attached to motor blower unit outlet tube and other end of the breathing tube is attached to the head cover 2 Adjust the b...

Страница 2: ...unusable butyl hood and dispose of properly 9 Inspect the butyl hood for damage such as holes tears or broken seams If the hood is damaged in any way dispose of the hood 10 Clean disinfect and inspect the PAPR blower unit after each use Surface clean the blower unit by using a damp sponge soaked in an approved cleaning solution to wipe the exterior surfaces of the filter motor blower assembly the ...

Страница 3: ...k of each filter cartridge and the rubber molding inside the threaded inlet Dispose of used filters cartridges in accordance with applicable regulations Cleaning of equipment 1 Surface clean the Turbo Unit at the end of the shift unit after each use by using a damp sponge soaked in an approved cleaning solution to wipe the exterior surfaces of the filter motor blower assembly the breathing tube th...

Страница 4: ...er cartridge or incorrect filter cartridge selection d Examine the outside of the battery pack for cracks Replace if damaged 4 Breathing Tube a Carefully examine the entire breathing tube Look for tears holes or cracks b Bend the tube to verify that it is flexible 5 Airflow Check a With the breathing tube assembly disconnected from the Turbo PAPR blower unit and the system running insert the base ...

Страница 5: ...Inspection and Record Keeping Breath Easy Turbo PAPR Date Inspected PAPR ID CE Turbo Unit Checked Breathing Tube Checked Airflow Rate cfm Comments Initials Page 5 of 5 3M Breathe Easy Turbo PAPR 6 15 06 ...

Отзывы: