SAFETY INFORMATION

Read, understand, and follow all safety information contained in these instructions prior to installation and use of the Aqua-Pure AWS  
Series Residential Water Softener. Retain these instructions for future reference.  Failure to follow installation, operation and mainte-
nance instructions may result in property damage and will void warranty.

Intended use:

The Aqua-Pure AWS Series Residential Water Softener is intended for use in softening water in homes and has not been evaluated for 
other uses.  The system must be installed indoors near the point of entry of a home water line, and be installed by qualifi ed professional 
installers according to these installation instructions.

EXPLANATION OF SIGNAL WORD CONSEQUENCES

W

WARNING

Indicates a potentially hazardous situation, which, if not avoided, could result in death or serious injury 
and/or property damage.

CAUTION

Indicates a potentially hazardous situation, which, if not avoided, may result in property damage.

WARNING

To reduce the risk associated with choking: 

• 

Do not

 allow children under 3 years of age to have access to small parts during the installation of this product.

To reduce the risk associated with ingestion of contaminants:

• 

Do not 

use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.

To reduce the risk of physical injury: 

•  Shut off inlet water supply and depressurize system as shown in manual prior to service.

To reduce the risk associated with a hazardous voltage:

•  If the home electrical system requires use of the cold water system as an electrical safety ground, a jumper must be used to ensure a suffi cient ground connection 

across the fi lter installation piping — refer installation to qualifi ed personnel.

• 

Do not

 use the system if the power cord is damaged — contact qualifi ed service personnel for repair.

To reduce the risk associated with back strain due to the heavy weight of the various system components:

•  Follow safe lifting procedures.

CAUTION

To reduce the risk associated with property damage due to water leakage:

• 

Read and follow 

Use instructions before installation and use of this water treatment system.

•  Installation and use 

MUST

 comply with existing state or local plumbing codes.

• 

Protect from freezing. 

Relieve pressure and drain system when temperatures are expected to drop below 33° F (1° C).

• 

Do not 

install systems in areas where ambient temperatures may go above 110° F (43.3° C).

• 

Do not 

install on hot water supply lines.  The maximum operating water temperature of this fi lter system is 110°F (43.3°C).

• 

Do not

 install if water pressure exceeds 100 psi.  If your water pressure exceeds 80 psi (552 kPa), you must install a pressure limiting valve. Contact a plumb-

ing professional if you are uncertain how to check your water pressure.

• 

Do not

 install where water hammer conditions may occur.  If water hammer conditions exist you must install a water hammer arrester.  Contact a plumbing 

professional if you are uncertain how to check for this condition.

•  Where a backfl ow prevention device is installed on a water system, a device for controlling pressure due to thermal expansion must be installed.
• 

Do not

 use a torch or other high temperature sources near fi lter system, cartridges, plastic fi ttings or plastic plumbing.

•  On plastic fi ttings, never use pipe sealant or pipe dope. 

Use PTFE thread tape only,

 pipe dope properties may deteriorate plastic.

•  Take care when using pliers or pipe wrenches to tighten plastic fi ttings, as damage may occur if over tightening occurs.
• 

Do not

 install in direct sunlight or outdoors without adequate protection from the elements.

•  Mount system in such a position as to prevent it from being struck by other items used in the area of installation.
•  Ensure all tubing and fi ttings are secure and free of leaks.
• 

SHUT OFF FUEL OR ELECTRIC POWER SUPPLY TO WATER HEATER

 after water is shut off.

• 

Do not

 install system where water lines could be subjected to vacuum conditions without appropriate measures for vacuum prevention.

• 

Do not

 apply heat to any fi tting connected to Bypass or Control Valve as damage may result to internal parts or connecting adapters.

•   Install on a fl at/level surface. It is also advisable to sweep the fl oor to eliminate objects that could pierce the brine tank.

To reduce the risk associated with property damage due to plugged water lines:

•  Pay particular attention to correct orientation of control valve. Water fl ow should match arrow on control valve. The Inlet and Outlet of other water treatment 

equipment products will vary depending on the control valve brand used.

IMPORTANT NOTES

• 

The system should be installed on cold water lines only. 

• 

Failure to follow installation, operation and maintenance instructions will void warranty.

Содержание Aqua-Pure AWS250M

Страница 1: ...S METERED WATER SOFTENERS MODELS AWS100M AWS150M AWS200M AWS250M AWS300M INSTR2198 0709 Installer please leave with homeowner Homeowner retain for future reference a 3M company CUNO Incorporated 400 R...

Страница 2: ...t from freezing Relieve pressure and drain system when temperatures are expected to drop below 33 F 1 C Do not install systems in areas where ambient temperatures may go above 110 F 43 3 C Do not inst...

Страница 3: ...MECHANICAL 1 Do not use petroleum based lubricants such as Vaseline oils or hydrocarbon based lubricants Use only 100 silicone lubricants 2 All plastic connections should be hand tightened Thread tap...

Страница 4: ...gh to be objection able a pre lter can increase the ef ciency of the softener and reduce the amount of maintenance required LOCATION SELECTION Location of a water treatment system is important The fol...

Страница 5: ...to connect 1 2 inch 1 3 cm plastic tubing to the drain line connection of the control valve 2 If the backwash ow rate exceeds 5 gpm 22 7 lpm or if the unit is located 20 40 ft 6 1 12 2 m from drain us...

Страница 6: ...ntly in progress CAMSHAFT FRONT END The corresponding slot for the number is positioned at the optical sensor which is approximately 90 degrees out of phase Regeneration Cycle Indicators C0 Treated Wa...

Страница 7: ...troller 5 PM indicates that the time displayed is between 12 00 noon and 12 00 midnight there is no AM indicator PM indicator is not used if clock mode is set to 24 hour 6 When MIN is displayed the va...

Страница 8: ...ther with the arrow buttons 3 UP arrow Generally used to scroll up or increment through a group of choices 4 Regenerate Used to command the controller to regenerate Also used to change the lock mode P...

Страница 9: ...ning an hourglass icon will be displayed Repeat this process for each cycle until the system is back into the treated water mode IMPORTANT NOTES When the controller gets to cycle C4 Pause cycle there...

Страница 10: ...y For a delayed regeneration at the next set time of regeneration Push the REGEN button once The recycle symbol will be ashing on the display Push the REGEN button again to cancel For an immediate reg...

Страница 11: ...ping from the valve drain line B When all of the air has been purged from the media tank water begins to ow steadily from the drain line open the main supply valve all of the way This will purge the n...

Страница 12: ...o the brine draw position Hold the REGEN button down for 5 seconds The controller will begin a manual regen and advance the control valve to the cycle C1 Backwash Press the SET and UP button to advanc...

Страница 13: ...ld be connected to a non switched power source PROGRAMMING The controller is designed to operate by only setting the time of day and the day of the week The remaining settings have been set at the fac...

Страница 14: ...regeneration 99 day calendar override timer Amount of salt used per regeneration System capacity Hardness To make changes Time of day When the Time of Day is displayed push SET The time will ash Use...

Страница 15: ...t simple programming possible the dealer installer has three salt amount options to choose from These are set up to give the installation the maximum performance based on the inputs by the dealer inst...

Страница 16: ...timated total system capacity is displayed in kilograins kilograms CaCO3 that could be removed by the fully regenerated media bed This value is derived by standard water treatment industry norms The s...

Страница 17: ...y in gallons 0 65536 gallons H11 Average usage for Thursday in gallons 0 65536 gallons H12 Average usage for Friday in gallons 0 65536 gallons H13 Average usage for Saturday in gallons 0 65536 gallons...

Страница 18: ...ontrol the regeneration cycle The control module has several variations When replacing the controller use the same model or some functions may not work This is an electronic controller that is program...

Страница 19: ...e camshaft or the motor When the controller is powered up the camshaft will be rotated to the home position OPTICAL SENSOR The optical sensor is mounted to the top plate The camshaft cup rotates throu...

Страница 20: ...slot The offset enable the service person to view the number at the top of the cup and deter mine which slot is at the optical sensor IMPORTANT NOTE If any part of the camshaft is broken or damaged th...

Страница 21: ...er Slack or loose wires can become tangled in the camshaft 1 Depending on which harness is being installed plug the connector into the motor or turbine 2 Route the harness through the opening at the b...

Страница 22: ...air a bent spring 2 Position yourself on the spring side of the valve discs 3 Position the spring over the valve body close to nal position The wide spring segments will be located at the wide valve d...

Страница 23: ...al end without rubber coating should be visible 2 Push down on the shoulder to position the valve disc completely into the port cavity The metal portion will be positioned straight up and the top of t...

Страница 24: ...tank Clean injector screen and injector once a year 1 Unplug the wall mount transformer 2 Remove cover Shut off water supply or put bypass valve s into bypass position 3 Relieve system and valve press...

Страница 25: ...o the service position and purge the air out of the system 10 The system will require the startup procedure to be performed in order to operate appropriately CHECK TURBINE OPERATION After the turbine...

Страница 26: ...p of the display under the day of the week When the correct day is agged push SET The controller is ready to operate The media tank should be ready for operation 5 Hold the REGEN button on the control...

Страница 27: ...d substantiated by test data These models are efficiency rated The efficiency rating is valid only at the stated salt dose and flow rate They have demand initiated regenerated DIR feature that complie...

Страница 28: ...ts C If motor continues to rotate inde nitely replace the following components in this order Optical sensor Wire Harness Motor Controller 4 Brine tank over ow A Uncontrolled brine re ll ow rate A Remo...

Страница 29: ...14 System using more or less salt than salt control is set for A Inaccurate setting A Make correct setting B Foreign matter in controller causing incorrect ow rates B Remove salt controller and ush o...

Страница 30: ...0P x3 10 Cyclone Assy C04N 44 C04N 44 C04N 54 C04N 54 T04N 65 11 Tank Base T06 8P T06 10P T06 10P T06A 12P T06A 14F 12 Brine Line Tubing 13000X 13000X 13000X 13000X 13000X 13 Brine Tank Complete BT153...

Страница 31: ...able Assembly 8 1000226 Screen Cap Assembly w O ring Injector High Ef ciency Options 9 1030410 1030412 1035736 G Injector High Ef ciency Tan J Injector High Ef ciency Lt Blue L Injector High Ef ciency...

Страница 32: ...r mail your request to CUNO Incorporated 400 Research Parkway Meriden CT 06450 CUNO and Aqua Pure are trademarks of 3M Company used under license 3M is a trademark of 3M Company Tested and Certified U...

Отзывы: