background image

PART

Typically replaced

Comment

A

 Filter cover 

If damaged  

To Hold and protect the filters

B

 Spark arrestor 

When needed 

Replace deformed or damaged to 

protect the particle filter from sparks 

and spatter

C

 Pre-filter  

When needed, at least 

weekly.

Regular replacement of the prefilter 

extends the life of the particle filter, 

saving money while also increasing the 

battery run-time

D

 Particle filter  

When needed, at least 

every month  

Replace when particle filter indicator 

becomes red. Otherwise, replace 

whenever the battery operating time 

becomes too short, or when the low 

airflow alarm is triggered by a fully 

loaded filter.

E

 Gas filter  

According to 

predetermined 

employer change-out 

schedule

Smell and taste is not recommended 

as a measure for determining when to 

change gas filters.

F

 Odour filter  

Change when 

unpleasant  smell  occur    

Odour filter is not neccessary when a 

gas and vapour filter is used

G

 Adflo Battery  

When needed

Replace if the battery is no longer 

taking charge to an acceptable level

H

 Battery charger  

If damaged  

Replace if any parts are damaged

I

 Breathing tube 

If damaged or 

contaminated

Use a breathing tube cover to extend 

the life time or a rubber breathing tube 

for use in heavy duty environments

Replacement table 3M

 Adflo

 Powered Air Purifying Respirator

 What is listed above are basic needs. For detailed instructions and guidance, always follow the user instruction.

Содержание Adflo

Страница 1: ...Care and maintenance for your Welding Protective Equipment 3M Science Applied to life...

Страница 2: ...aintain PPE If you don t keep up your maintenance you may get Reduced protection levels Reduced effective lifetime of equipment Resulting in the additional cost of replacement Correctly selected and u...

Страница 3: ...5 Respiratory helmets face seal If the face seal is damaged there is a risk that contaminated air will get inside the helmet Verify it s in place and free from splits and tears 6 Respiratory helmets b...

Страница 4: ...ely replace either the particle or the gas vapour filter as needed you don t need to change both filters at the same time Note that a particle filter must be used at all times The Li Ion batteries are...

Страница 5: ...by a fully loaded filter E Gas filter According to predetermined employer change out schedule Smell and taste is not recommended as a measure for determining when to change gas filters F Odour filter...

Страница 6: ...ur helmet comfort with different accessory configurations while you use the new helmet controls to adjust the respiratory airflow to your preferences A Outer Protection Plate B Inner Cover Plate C Vis...

Страница 7: ...Learn more about product maintenance from Speedglas YouTube channel Scan the QR code or visit youtube com 3MSpeedglas...

Страница 8: ...blishing a thorough respiratory protection program requires both selecting the correct respirators and a plan to change out your gas vapor cartridges Selecting the welding PPE include various paramete...

Отзывы: