background image

 

78-0013-6978-0-B

2

Safety Precautions

Protective Eyewear

 

CAUTION

To reduce the risk associated with eye injury:| 

- Safety glasses should be worn when handling chemicals and cleaving the optical fiber.

Chemical Precautions

 

WARNING

To reduce the risk associated with fire:
- Storage, use and disposal of isopropyl alcohol should be per your company health, safety and environmental instructions. Refer to 
material safety data sheet for health hazards, safe handling, proper use and control measures.

 

CAUTION

To reduce the risk associated with eye or skin irritation from fiber gel in connector: 

- Product contains phenylmethyl silicone (63148-58-3), hydrophobic silica (68611-44-9) and may cause minimal eye irritation. Avoid 
contact with eyes and wash hands before eating or smoking. Upon eye contact, immediately flush eyes with water while holding eyelids 
open and continue flushing for ten minutes. Contact a physician. Upon skin contact, wash with soap and water. Product Information: 
Material Safety Data Sheet or call 3M at 1-800-364-3577 or 651-737-6501 (24 hours).

Bare Fiber Handling

 

CAUTION

To reduce the risk associated with handling sharp glass fibers: 

- Cleaved glass fibers are sharp and can pierce the skin. Use tweezers when handling shards and dispose of them properly per your com-
pany health and safety instructions.

Fiber/Cable Handling

NOTICE

To reduce the risk associated with fiber damage: 

- Optical fiber can be damaged by excessive tensile, compressive and bending forces. Consult the manufactures’ specifications for proper 
handling instructions. Laser Safety

Laser Safety

 

CAUTION

To reduce the risk associated with eye damage from exposure to laser light: 

- Take the proper precautions when working with optical fiber because invisible laser light may be present.  The principal laser hazard 
when working with fiber optics is injury to the eye.  Never look directly into the fiber or connector using the naked eye or a microscope.

Содержание 8865-C

Страница 1: ...3M No Polish ST Connector SM and MM Flat Splice 250 900 µm Instructions 3 November 2012 78 0013 6978 0 B The Network of Networks ...

Страница 2: ...lushing for ten minutes Contact a physician Upon skin contact wash with soap and water Product Information Material Safety Data Sheet or call 3M at 1 800 364 3577 or 651 737 6501 24 hours Bare Fiber Handling CAUTION To reduce the risk associated with handling sharp glass fibers Cleaved glass fibers are sharp and can pierce the skin Use tweezers when handling shards and dispose of them properly per...

Страница 3: ... protrude more than 1 mm 04 inches beyond where the 900 µm buffer is stripped away One way to help ensure this is to use the clamp on the fiber holder during the stripping process Here s how Place the fiber holder on the fiber facing backwards clamp closet to cut end and 20 cm 8 inches from the end of the fiber Secure the fiber into the SEMI TIGHT BUFFER groove of the clamp Proceed to strip the fi...

Страница 4: ...when using loose tube or semi tight buffered fiber 2 5 With the guide funnel fully forward lay the fiber in the central groove along the length of the fiber holder as shown Position it such that the stripped and cleaved portion extends slightly beyond the tip of the guide funnel If the fiber has a noticeable amount of curvature orient it so the curvature is directed downward toward the fiber holde...

Страница 5: ...of 3 mm sec Guide funnel door opened by cam on the assembly base Fiber bow should start when the white line on fiber holder aligns with the BOW START mark on the assembly base 2 8 While slowly sliding the fiber holder toward the connector a bow should start to form in the fiber when the white line on the fiber holder aligns with the white BOW START line on the assembly base If a bow is not seen sl...

Страница 6: ...nstall it into the receptacle 2 2 reinsert the fiber holder into the assembly base being careful to avoid damaging the fiber and proceed with step 2 12 To remove the connector from the fiber place it into the cap popper cavity on the assembly base oriented as shown Then press down firmly using equal pressure at each end of the connector This action will pop the element activation cap upward thereb...

Страница 7: ...h Connector ST Assembly Tool 1 package RoHS Compliant 2002 95 EC means that the product or part Product does not contain any of the substances in excess of the maximum concentration values in EU Directive 2002 95 EC as amended by Commission Decision 2005 618 EC unless the substance is in an application that is exempt under EU RoHS This information represents 3M s knowledge and belief which may be ...

Страница 8: ...y Limited Remedy Limited Liability This product will be free from defects in material and manufacture for a period of one 1 year from the time of purchase 3M MAKES NO OTHER WARRANTIES INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE If this product is defective within the warranty period stated above your exclusive remedy shall be at 3M s opt...

Отзывы: