8
4.5
When the fiber holder is pushed toward the connector and
stops, the fiber bow should be seen as below. The fiber will
bow and lift the middle cover for rigid fibers and remain
closed for flexible fibers.
fiber bow
middle cover
5.0 Splice Actuation
5.1
While there is a fiber bow, press actuator button firmly
to actuate the splice. An audible click will be heard when
properly completed.
Note: If continuity verification is required or you need
to test the link prior to placing in service you will
perform this step now. Do not proceed to step
5.2 until testing is complete. If re-termination is
required, please skip to Section 6, 3M
™
No Polish
Connector (NPC) Re-termination.
5.2
Press release lever to allow forward motion of funnel.
Push ears to move funnel forward and actuate buffer
clamp.
5.3
Open the clamp and lift the covers to release fiber.
5.4
Slide fiber holder from actuation tool.
Optional: 3M
™
No Polish Connector can be tested in the tool
using a SC coupling.
5.5
Pull connector from coupling and clean connector end
face with isopropyl alcohol and a lint-free cloth.
5.6
After removing connector from the coupling, replace
the dust cap on the ferrule until connector is ready to be
placed in service.