Section 1. 
Theory of Operation

(Refer to Fig. 1)

The 3M™ Model 725 Wrist Strap
Monitor is designed to monitor the
operation of the wrist strap grounding
system of a single operator. The
system features special wrist bands 
and ground cords that contain two
independent conductors.*

The Model 725 Monitor performs a
resistance measurement by applying an
electrical current of less than 1 µA.
The path for the current is through one
conductor of the wrist strap ground
cord that contains a current-limiting
resistor, through one side of the wrist
band, through the skin of the wearer
under the band, through the second
side of the wrist band, through the
second conductor of the wrist strap
ground cord that contains a current-
limiting resistor, and finally back to 
the monitor.

If the resistance of the wrist strap loop
is less than 35 megohms**, the wrist
strap ground cord, wrist band, and the
interface of the wrist band to the arm
of the wearer are considered to be
functioning correctly. If the measured
resistance is over 35 megohms**, a
red lamp flashes along with a chirping
audible alarm.

In addition, the Model 725 monitors
the ground clip connection to a
predetermined electrical ground. 
This is accomplished by measuring 
the resistance from the monitor,
through one conductor of the
monitor’s ground cord and metal clip,
through the ground point conducting
medium, through the other metal clip
and conductor of the monitor’s ground
cord, and finally back to the Model
725 Monitor. If the resistance of this
loop exceeds 10 megohms***, a red
lamp will illuminate with a continuous
audible alarm. This indicates that 
there is a problem with the monitor’s
ground cord or the ground point
connection. 

Fig. 1 

Model 725 Wrist Strap Monitor with dual conductor wrist strap assemblies 

Model 725
Wrist Strap 
Monitor

Dual Conductor
Metal Wrist Strap*

Dual Conductor
Fabric Wrist Strap*

* 3M Dual Conductor Cord & Wrist Band are 

required for use with the 725 Monitor,
ordered separately.

** Resistance values are ±15%
*** Resistance values are +15%, -50%

Содержание 725

Страница 1: ...Power Supply 9 Volt alkaline battery not supplied Test Voltage 9 Vdc maximum Test Current Less than 1 microamp Upper Resistance Limits Wrist Strap 35 Megohms Ground Clip 10 Megohms Accuracy 15 Environ...

Страница 2: ...3 Model 725 Wrist Strap Monitor Instructions...

Страница 3: ...ork Surface 7 4 Installation Under Work Bench 8 5 Installation Using 723 Belt Clip 9 6 Parking Clip 9 7 Battery Replacement 9 8 Verification Procedure for the Model 725 Monitor 10 9 Specifications 11...

Страница 4: ...f Symbols Caution refer to user instruction manual See user instruction manual for explanation of the indicator lamp See user instruction manual for explanation of the audible alarm Safety Information...

Страница 5: ...band to the arm of the wearer are considered to be functioning correctly If the measured resistance is over 35 megohms a red lamp flashes along with a chirping audible alarm In addition the Model 725...

Страница 6: ...e The Model 725 monitors the battery voltage and alerts the operator when it is necessary to change the battery When the battery voltage falls below 6 volts the red lamp will illuminate with no audibl...

Страница 7: ...of the Model 725 Monitor Plugging into the jack activates the monitor and causes it to emit a short beep and the red lamp to momentarily flash If the red lamp flashes with an intermittent audible alar...

Страница 8: ...resistor by the Model 725 Monitor Note Although the work surface is grounded by the Model 725 Monitor it is not monitoring the ground to the work surface 3M 8200 Series Work Surfaces use the female 1...

Страница 9: ...the front edge of the work bench Attach the monitor to the work bench with the screws It may be necessary to pre drill pilot holes for the screws Attach the dual conductor ground clip or each wire of...

Страница 10: ...l 725 Monitor See Section 6 Section 6 Parking Clip Fig 5 A parking clip is supplied with the Model 725 Monitor allowing mobile users to silence the ground clip disconnect alarm Attaching the dual cond...

Страница 11: ...snap firmly into place Section 8 Verification Procedure for the Model 725 Monitor The Model 725 Wrist Strap Monitor cannot be recalibrated after the initial factory calibration However the following...

Страница 12: ...rt the opposite ends together Set the RSB as follows and observe the lamp and audible alarm 5 0 Megohms Red lamp OFF audible alarm OFF 11 5 Megohms Red lamp ON Continuous audible alarm ON Continuous t...

Страница 13: ...rist Band large 2368 Dual Conductor Fabric Wrist Band adjustable 2381 Dual Conductor Metal Wrist Strap small 2382 Dual Conductor Metal Wrist Strap medium 2383 Dual Conductor Metal Wrist Strap large 23...

Страница 14: ...on of Electrostatic Sensitive Devices 3M Tech Response 123 Pulsed Current vs Constant Current in Work Station Monitors 3M Static Digest Issue No 1 1998 Disc Drive Industry Static Control Consideration...

Страница 15: ...nty Exclusions THE FOREGOING EXPRESS WARRANTY IS MADE IN LIEU OF ALL OTHER PRODUCT WARRANTIES EXPRESS AND IMPLIED INCLUDING FITNESS AND MERCHANT ABILITY The express warranty will not apply to defects...

Отзывы: