9
Product Dimensions (Figure 4)
Part Number
Description
5625004
RO Membrane Cartridge
5628902
HF65-CL Pre-filter
89-1331202
Permeate-pump
99-103301
Flow control
96-410502
Regulator, 80 psi
60-931401
Automatic Shut-off Valve
56-12301
Tank
60-235280
Tank Shut-off Valve
Contact dealer for replacement parts
Storage Tank and RO System Sanitizing Instructions:
Important Note: Tanks should be sanitized every two years or if RO is out of service for an
extended period of time.
Sanitizing the storage tank requires:
• Common household bleach (5.25% non-scented) or sanitizing agent
• Eye dropper or plastic oral syringe
a.) Turn off incoming water supply.
b.) Disconnect the 1/4” line from marked “Tank Outlet” to pressure tank.
c.) Insert 15ml (0.5 ounces) of bleach or sanitizing agent into 1/4” line to pressure tank.
d.) Reconnect the 1/4” line to pressure tank.
e.) Turn ON the feedwater supply.
f.) Wait 4-5 hours.
g.) Open pressure tank sample valve and empty tank to drain.
h.) Sanitizing is now complete.
i.) If there is any residual chlorine/bleach taste in the next tank full, drain tank completely
a second time.
Replacement Parts
A
XX/XX/15
DA
FIRST RELEASE, ECN 16195
PRELIMINARY
FIGURE 1
ISOMETRIC VIEW
38
37
ISOMETRIC VIEW
39
40
35
36
32
43
42
33
2X
41
34
FIGURE 1
EXPLODED
31
FIGURE 1
VIEW OF MOUNTING HOLES
2X
(10 1/2")
4X ( 3/8")
4X (5/8")
2X
4X (3/4")
(9")
4X (1/4")
2X
CENTRALLY LOCATE
AS SHOWN
REVISIONS
DESCRIPTION
LTR
DATE APPROVED
BY
ISSUED:
SIZE CODE IDENT. NO.
DRAWING NO.
D 15472
SCALE:DO NOT SCALE
D.Apicella
SHEET: 1 OF 2
56362
DATE
APRVD
CHECKED
UNLESS OTHERWISE SPECIFIED:
DATE
FORM NO. ENG 132 0110
04/21/15
DRAWN
SYSTEM, SGLPX00-CL
BREAK EDGES - - - - - -
MODEL: 56362
MACHINED SURFACES - - - -
3M Purification Inc.
12 7/8"
16 1/2"
44
22 5/8"
3"
1. DESIGN PRESSURE: 125 PSIG
DESIGN TEMPERATURE: 100°F MAX.
2. ALL MATERIAL USED IN THE CONSTRUCTION OF THIS ASSEMBLY THAT CONTACT POTABLE
WATER SHALL BE FDA, CFR 21 AND/OR NSF COMPLIANT.
3. APPLY PTFE TAPE TO ALL THREADED CONNECTIONS PRIOR TO ASSEMBLY.
4. DIMENSIONS ENCLOSED WITHIN PARENTHESES ( ) ARE REFERENCE VALUES AND DO NOT
REQUIRE INSPECTION.
5636203 SGLP200-CL-BP
2
W/AUTOBYPASS KIT
5636202 SGLP200-CL 2
5636201 SGLP100-CL 1
PART NO.
MODEL NO.
FIGURE REMARKS
THIS DOCUMENT CONTAINS PROPRIETARY, CONFIDENTIAL,
AND/OR PRIVILEGED INFORMATION WHICH IS THE PROPERTY
OF 3M PURIFICATION INC. OR ITS DESIGNATED ENTITY AND IS
SUBMITTED FOR USE ONLY IN CONNECTION WITH PROPOSED
OR AUTHORIZED WORK. THE INFORMATION ON THIS
DOCUMENT SHALL NOT BE USED, COPIED, DISCLOSED,
DISSEMINATED OR DISTRIBUTED WITHOUT WRITTEN CONSENT
AND THIS DOCUMENT AND ALL COPIES SHALL BE RETURNED
UPON REQUEST.
© 2015, 3M COMPANY. ALL RIGHTS RESERVED.
XX/XX/15
DA
FIRST RELEASE, ECN 16195
A
PRELIMINARY
FIGURE 2
SAME AS FIGURE 1
EXCEPT AS SHOWN
3M Purification Inc.
BY
04/21/15
D.Apicella
SYSTEM, SGLPX00-CL
SIZE CODE IDENT. NO.
DRAWING NO.
D 15472
UNLESS OTHERWISE SPECIFIED:
BREAK EDGES - - - - - -
APRVD
ISSUED:
DATE
MACHINED SURFACES - - - -
CHECKED
APPROVED
SHEET: 2 OF 2
DATE
LTR
56362
DATE
DESCRIPTION
MODEL: 56362
FORM NO. ENG 132 0110
REVISIONS
DRAWN
SCALE:DO NOT SCALE
33
2X
39
2X
41
32
40
2X
42
FIGURE 2
EXPLODED
34
35
36
37
ISOMETRIC VIEW
38
43
44
31
FIGURE 2
ISOMETRIC VIEW
THIS DOCUMENT CONTAINS PROPRIETARY, CONFIDENTIAL,
AND/OR PRIVILEGED INFORMATION WHICH IS THE PROPERTY
OF 3M PURIFICATION INC. OR ITS DESIGNATED ENTITY AND IS
SUBMITTED FOR USE ONLY IN CONNECTION WITH PROPOSED
OR AUTHORIZED WORK. THE INFORMATION ON THIS
DOCUMENT SHALL NOT BE USED, COPIED, DISCLOSED,
DISSEMINATED OR DISTRIBUTED WITHOUT WRITTEN CONSENT
AND THIS DOCUMENT AND ALL COPIES SHALL BE RETURNED
UPON REQUEST.
© 2015, 3M COMPANY. ALL RIGHTS RESERVED.
12 7/8”
Содержание 5636201
Страница 12: ...11 Figure 5 5 8 4X 10 1 2 2X 3 4 4X 9 2X 3 8 8X 1 4 4X ...
Страница 14: ...13 ...
Страница 15: ...14 NOTES ...