Shut Off Procedure

RO membrane cartridge MUST be changed every 24 months or sooner. The pre-filter and post filter cartridges MUST be changed every 12 months 
or sooner. 

1.  Unplug system from the electrical outlet, which will shutoff feedwater to RO unit.

2.  Confirm the operating pressure gauge (left) decreases to 0 psi. Note: Tank pressure gauge (right) will not decrease from the observed 

pressure.  

Pre-Filter Cartridge (blue label) Replacement:

1.  Push and hold yellow tab to release cartridge locking mechanism while simultaneously rotating cartridge to the left. 

2.  Using both hands and holding the cartridge from the bottom, rotate the cartridge a quarter turn to the left and gently pull down.  

NOTE: A small amount of water will drain from manifold as cartridge is removed.

3.  Remove red sanitary cap from new cartridge. Ensure o-rings are seated into their grooves. Install with a quarter turn to the right until cartridge 

come to a complete stop. NOTE: Cartridges are keyed to fit in proper location only. 

RO Membrane Cartridge (green label) Replacement:

1.  Remove the reject tubing from the RO membrane cartridge. (See Figure 1).

2.  Push and hold yellow tab to release RO membrane cartridge locking mechanism while simultaneously rotating RO membrane cartridge to the 

left.

3.  Using both hands and holding the RO membrane cartridge from the bottom, rotate the RO membrane cartridge a quarter turn to the left and 

gently pull down. NOTE: A small amount of water will drain from manifold as cartridge is removed.

Routine Maintenance Cartridge Change out Instructions (Pre/ Post Filter and RO Membrane Cartridge)

WARNING

Read entire manual. Failure to follow all guide and rules could cause personal injury or property damage.

• 

Check with your local public works department for plumbing codes. You must follow their guidelines as you install the water filtration system.

• 

Your water filtration system will withstand up to 125 pounds per square inch (psi) water pressure.

To reduce the risk associated with choking:

• 

DO NOT allow children under 3 years of age to have access to small parts during the installation of this product.

To reduce the risk of serious injury associated with the potential ingestion of chemicals or contaminants:

• 

Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.

• 

Flush RO Cartridge: Before use, you must flush the RO cartridge as specified in the installation instructions, and discard any water generated until flush is 
complete. Failure to do so could cause serious injury from exposure to chemicals that can be extracted from the RO membrane during this initial flush.

• 

Sanitize and Flush Tank: Before use, you must sanitize and flush the hold tank as specified in the installation instructions. Sanitizing the hold tank minimizes 
the risk for exposure to contaminants. Failure to flush the hold with water after sanitizing could cause serious injury from exposure to sanitizer present. 

NOTICE

To reduce the risk associated with property damage due to water leakage or flooding:

• 

Read and follow Use Instructions provided with the original system prior to use of this replacement cartridge.

• 

The pre-filter and post-filter cartridges MUST be changed every 12 months, or sooner if the rated capacity is achieved or a noticeable reduction in flow 
occurs.

• 

The RO membrane cartridge MUST be changed every 24 months, or sooner if a noticeable decrease in flow or TDS reduction occurs.

• 

Failure to replace the filters and RO membrane cartridges at recommended intervals may lead to reduced filter performance and failure, causing property 
damage from water leakage or flooding.

• 

Protect from freezing, remove all cartridges when temperatures are expected to drop below 40°F (4.4°C).

• 

DO NOT install systems in areas where ambient temperatures may go above 100°F (37.8°C).

• 

DO NOT install on hot water supply lines. The maximum operating water temperature of this filter system is 100°F (37.8°C).

• 

DO NOT install if water pressure exceeds 125 psi (862 kPa). Contact a plumbing professional if you are uncertain how to check your water pressure.

IMPORTANT NOTE:

The cartridges have unique keys and are color coded. The pre-filter cartridge has a blue label and is keyed to fit into the left cartridge head on the manifold. The RO 
membrane cartridge has a green label and is keyed to fit into the right cartridge head on the manifold. 

Содержание 5629101

Страница 1: ...uctions System tested and certified by NSF International against NSF ANSI Standard 58 for material safety and the claims specified on the Performance Data Sheet and against CSA B483 1 3M Water Filtration Products Installation and Operation Instructions for ScaleGardTM HP Reverse Osmosis System Original Instructions ...

Страница 2: ...rmation 3 4 Parts List 5 Feedwater Requirements 6 Other Requirements 6 Equipment Set Up and Installation 7 System Start Up 10 Routine Maintenance 15 16 Troubleshooting Guide 17 Product Replacement Parts 18 Limited Warranty Back Cover ...

Страница 3: ...to have access to small parts during the installation of this product To reduce the risk of serious injury associated with the potential ingestion of chemicals or contaminants Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system Flush RO Cartridge Before use you must flush the RO cartridge as specified in the installa...

Страница 4: ...ed water inlet line you MUST install an appropriate pressure relief valve Pressure relief valve must be maintained and inspected every 6 months Contact a plumbing professional if you are uncertain how select install maintain a pressure relief valve DO NOT install in direct sunlight or outdoors DO NOT install near water pipes which will be in path of a drilling tool when selecting the position to m...

Страница 5: ...r and RO 6239302 220 240VAC w out Pre filter and RO HF90 CL RO Pre Filter 1 5613529 HFRO 500 RO membrane 1 5626903 Equipment Components Sold Separately Description Quantity Part Number Install Kit Sold Separately 1 6841441 SGHP Pre Expansion Assembly Manifold 1 6235205 SGHP RO Expansion Assembly Manifold 1 6232705 HFRO 700 RO Membrane 1 5626904 HFRO 33 Recovery Kit 1 50 93201 Sold Separately Descr...

Страница 6: ...g system upstream If the particle count is 1000 counts ml for particles less than 2 micron size or turbidity is greater than the recommended 5 NTU limit then additional pre filtration may be required Contact your dealer distributor for details It is recommended to install an SGHP RO EXP and SGHP Pre EXP under the following conditions 1 If more production capacity is needed 2 If installed in a loca...

Страница 7: ... the ScaleGard HP reverse osmosis base unit and 0 5 or larger tubing diameter is required to complete installation Figure 1 Plumbing Diagram Bypass Provided by Installer Check Valve Provided by Installer 1 2 NPT Feed Water Inlet HF90 CL RO Pre Filter HFRO 500 RO Membrane 3 8 JG Outlet to drain Pre Filter sample valve Install kit shutoff valve Sold Separately Install kit shutoff valve Sold Separate...

Страница 8: ...d with property damage due to water leakage or flooding Mount ScaleGardTM HP base unit in such position as to prevent it from being struck by other items being used in the area of installation Ensure that the location and fasteners will support the weight of the system when installed IMPORTANT NOTES Allow a minimum of 3 7 6 cm clear space under filter to facilitate cartridge change 3 Hang manifold...

Страница 9: ...he ScaleGardTM HP reverse osmosis system are now complete IMPORTANT NOTE The cartridges have unique keys and are color coded The pre filter cartridge has a blue label and is keyed to fit into the left cartridge head on the manifold The RO membrane cartridge has a green label and is keyed to fit into the right cartridge head on the manifold RO Membrane Cartridge green label Installation Pre Filter ...

Страница 10: ... into electrical outlet 4 Open Pre Filter flush valve to vent air from system and flush for 10 gallons approximately 5 minutes 5 Close Pre Filter flush valve The unit operating pressure gauge left gauge should read between 110 120 psi See Operating Pressure instructions to adjust 6 Complete blending valve adjustment procedure below See instructions below 7 Close the blend line shut off valve Figur...

Страница 11: ...lush procedure is completed Failure to do so could cause serious injury from exposure to chemicals that can be extracted from the RO membrane during this initial flush 1 Open the tank line sample valve 2 Close the blend line shut off valve Figure 5 1 3 Operate the unit for 24 hours minimum to flush the RO membrane Discharge all water generated during the flushing procedure to drain 4 Close the tan...

Страница 12: ...On when the flow switch is closed signaling good flow ON X3 Green On when the reset button is being pressed down OFF Y1 Red On when the Inlet solenoid is being signaled by PLC to open make RO water ON Y2 Red On when the permeate rinse solenoid is being signaled by PLC to open rinse On for 25 seconds then OFF Y3 Red On when The service indicator light is being signaled by PLC to turn on OFF NO1 110...

Страница 13: ...bar for 220 240VAC systems the unit is off on full tank 1 Unit will cycle on when tank switch senses 40 psi TOGGLE CYCLE 1 Motor Pump stop 2 2 second delay the inlet solenoid closes 3 1 second delay the inlet solenoid opens 4 1 second delay the motor pump start 5 12 second delay check flow for three consecutive readings at 2 second intervals Note The TOGGLE CYCLE can will repeat 4 times 1 RETURN t...

Страница 14: ...is adjustment using the screw slot Turn the screw in to increase the operating pressure out to decrease the operating pressure Note A small amount of water may leak around the set screw this is normal 12 When the operating pressure is set replace the lock nut and recheck the operating pressure readjust if necessary Do not over tighten lock nut Check for water leaks repair as necessary 13 Unplug th...

Страница 15: ...roduct To reduce the risk of serious injury associated with the potential ingestion of chemicals or contaminants Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system Flush RO Cartridge Before use you must flush the RO cartridge as specified in the installation instructions and discard any water generated until flush i...

Страница 16: ...the cause is usually a problem with the tubing To Fix 1 Relieve pressure 2 Release tubing 3 Cut off at least 1 4 from end 4 Reattach tubing 5 Confirm connection is leak free Figure 9 How to Use Push in Connectors 4 Remove sanitary cap from new RO membrane cartridge Ensure o rings are seated into their grooves Remove drain fitting plug from new RO membrane cartridge Install with a quarter turn to t...

Страница 17: ...ne Check for 1 feedwater pressure 2 production flow rate 3 drain flow rate before replacing RO membrane Ensure drain line is not kinked or plugged Replace if needed RO membrane fouls high feed water hardness TDS Install RO add on head and cartridge Contact Dealer Install a HFRO 33 Recovery Kit Install water softener upstream RO membrane fouls high particle load in incoming water Install prefilter ...

Страница 18: ... Contact Dealer 85 9274 Shroud Contact Dealer 89 3220101 Pump Head Contact Dealer 89 2302 Pump Motor Contact Dealer 5613529 HF90 CL RO Pre Filter 5626903 HFRO 500 Cartridge 5626904 HFRO 700 Cartridge 50 93201 HFRO 33 Recovery Kit 6232631 TDS Monitor 24 500101 Flow Switch 25 15501 Pressure Switch 40 60 psi 25 15500 Pressure Switch 50 70 psi 60 103601 Inlet Solenoid Contact Dealer 6217402 Bypass Plu...

Страница 19: ...19 Notes ...

Страница 20: ...f 1 year from the date of purchase The filter cartridge or membrane is warranted to be free from defects in material and manufacture for one 1 year No warranty is given as to the service life of any filter cartridge or membrane as it will vary with local water conditions and water consumption 3M MAKES NO OTHER WARRANTIES OR CONDITIONS EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WAR...

Отзывы: