Technician Troubleshooting Guide
Model 481BA (D-20)
2
3
Intracom D-20
VOLUME
OFF ON
SP-205A
9
8
7
6
5
4
1
2
3
Figure 1. Operating Controls
Key
Control Name
Function
1
Power Switch
Provides power to mainstation.
2
Power Indicator Light
Indicates power is on and the system is ready to operate.
3
Volume Control
Adjusts INCOMING audio level.
NOTE: Volume level adjustments for alert tone and outside
speakers are set by the installer.
4
Channel Selector Switches (1-6)
These switches control talk/listen communication for
numbered channels. Operator touches switch to talk and
releases switch to listen.
5
Indicator Lights
Red indicates TALK mode.
Green indicates LISTEN mode.
Yellow (steady) indicates channel on "HOLD."
Yellow (flashing) indicates incoming call WAITING.
6
Hold Switch
Places selected channel in "HOLD" mode.
7
All Call Switch
Controls conversation with all channels simultaneously.
8
Standby Switch
Silences incoming audio to eliminate undesired background
noise pickup when unit is not in use. Touching any
CHANNEL SELECTOR SWITCH releases STANDBY
mode.
9
Standby Indicator Light
Indicates unit is in STANDBY mode.