3M 3M-08 Скачать руководство пользователя страница 2

Remove old unit

Label Wires to Old Unit

Mount the 3M-08

Separate front from back of unit. Grasp the 

front of the unit and the back of the unit and  pull apart. 
The thermostat body away from the base.
Hold the base against the wall, with the wires coming 
through the opening below the terminal block. 
Position the base for best appearance 
The 3M-08 can be mounted vertically or horizontally. 
chose the position that best suites your wall.
Attach the base to the wall with the two screws 
provided.
If you are mounting the base to sheet rock or if 
you are using the old mounting holes, use the 
plastic anchors provided. 

Drill a 3/16-in.(4.8mm) 
hole for the insert at 

each screw location, 
then mount the base.

PG

 3

PG

 4

Terminal Block

Switch electricity to the furnace and air conditioner OFF; 
then proceed with the following steps.
Remove cover from old thermostat. Most are snap-on types and simply pull 
off. Some have locking screws on the side or front. These must be loosened.   
Note the letters printed near the terminals. 
Carefully attach labels (enclosed) to each wire. Label the wires one at a time.  

You must have all the wires labeld before you procede.

 

Remove the wires from the terminals of the old thermostat.
Make sure the wires 

do not fall back inside

 the wall.  

Wind them around a pencil to 

keep them from falling

.

Remove the old thermostat from the wall. Fill wall 
opening with fiber glass insulation to prevent drafts.  

Caution

DO NOT REMOVE WIRES FROM OLD THERMOSTAT UNTIL YOU HAVE 
CAREFULLY LABELED THEM, WITH LABELS PROVIDED.
THERE IS NO STANDARD COLOR CODE FOR THESE WIRES.

Содержание 3M-08

Страница 1: ...at On replacement installations mount the new thermostat in place of the old one if possible On new Installations follow the guidelines listed below Locate the thermostat on an inside wall about 5 ft 1 5m above the floor and in a room that is used often Do not install it where there are unusual heating conditions such as in direct sunlight near a lamp radio television radiator register or fireplac...

Страница 2: ... mount the base PG 3 PG 4 Terminal Block Switch electricity to the furnace and air conditioner OFF then proceed with the following steps Remove cover from old thermostat Most are snap on types and simply pull off Some have locking screws on the side or front These must be loosened Note the letters printed near the terminals Carefully attach labels enclosed to each wire Label the wires one at a tim...

Страница 3: ...ostat will draw power from the C wire and this will extend battery life Optional Wire Connections What Wires Do you Have Strip insulation 3 8 in 9 5mm from wire ends Take care not to damage the labels for each wire in handling Connect labeled wires only to a terminal with corresponding letter Bend the wire slightly insert the wire under the contact plate and tighten the screw down onto the wire PG...

Страница 4: ...thermostat will go off if the batteries die This exposes your house to unexpected heat or cold and should be avoided Follow these procedures to verify you have correctly installed the unit To check Fan If you connected the G wire fan relay Switch the FAN switch to the ON position Verify that air is blowing from the system Return to AUTO position for normal operation To check HEAT mode Set the mode...

Страница 5: ...l over 1 year If the batteries are not replaced the thermostat will stop working 2 The 3M 08 can run on the C wire if available 24VAC ONLY As shown in the wiring diagrams The C wire is the other side of the 24VAC heating transformer If the C wire is used the batteries are not needed Power Options Check Unit cont Congratulations you have successfully installed your unit Please proceed to the OPERAT...

Страница 6: ...o the Heater Power STEP 2 Connect the W wire to the W terminal on the thermostat This connects the heater control line to the thermostat STEP 3 Connect the G wire to the G terminal on the thermostat This connects the Fan to the thermostat Your system is now conected to the thermostat Return To Page 7 Return To Page 7 2 WIRE Heating GAS MILLIVOLT or 24vac NOTE Wires marked with the dotted line are ...

Страница 7: ... Cooler compressor STEP 3 Connect the RH wire to the RH terminal on the thermostat This connects to the Heater Power STEP 4 Connect the RC wire to the RC terminal on the thermostat This connects to the Cooling Power STEP 5 Connect the W wire to the W terminal on the thermostat This connects to the heater control line STEP 6 Connect the G wire to the G terminal on the Thermostat This connects to th...

Страница 8: ...ems The 3M 08 is digital You can program your desired Heat and cool temperature by setting the dial The unit uses no harmful mercury A 5 minute minimum off time in COOL protects your air conditioning system from being damaged Two AA batteries not included are used to run the thermostat in some installation C wire installations require no batteries 3M 08 Features PG 15 1006 007 Customer Support 888...

Страница 9: ......

Страница 10: ......

Страница 11: ......

Страница 12: ......

Страница 13: ......

Страница 14: ......

Страница 15: ......

Страница 16: ......

Отзывы: