![3M 29100 Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/3m/29100/29100_instructions-and-parts-list_3044603011.webp)
7
Installation (Continued)
BOTH THE UPPER AND LOWER TAPING HEADS UTILIZE EXTREMELY SHARP KNIFE BLADES. THE
BLADES ARE LOCATED UNDER THE ORANGE BLADE GUARD WHICH HAS THE “WARNING – SHARP
KNIFE” LABEL. BEFORE WORKING WITH THE TAPING HEADS OR ATTEMPTING TO LOAD THE TAPE,
REFER TO FIGURES 4-1 AND 4-2 AND IDENTIFY THE BLADE LOCATION. KEEP HANDS OUT OF THESE
AREAS EXCEPT AS NECESSARY TO SERVICE THE TAPING HEADS.
After the taping head assembly has been unpackaged, examine the unit for damage that might have occurred
during transit. If damage is evident, file a damage claim immediately with the transportation company and also
your 3M Representative.
The taping heads can be used to replace existing or custom made machinery. It can be mounted for top taping or
bottom taping. Refer to box size specifications on page 5 and Figure 2-1 on page 6, for the following points in
making such installations:
1.
The case conveying system must positively propel the case in a continuous motion, not exceeding 150
feet per minute [45.7 m/min.], past the taping head assembly since the case motion actuates the taping
mechanism.
2.
If a pusher or cleated conveyor is being used, steps should be taken in the conveyor design to prevent the
pusher from contacting the applying or buffing roller arms which may result in damage to the taping
head. If this is not possible, contact 3M for assistance or suggested modifications that will provide
adequate operating clearance to the taping head assembly.
3.
Figure 2-1 illustrates the typical mounting relationship for opposing taping head assemblies to allow taping
of case heights down to 5.4 inches [135 mm]. To tape case heights down to 4 inches [100 mm], the
taping head assemblies must be completely staggered so only one tape seal is being applied at one
time.
4. Four (4) mounting studs are provided on the taping head side plates but special installations may require
alternate means for mounting. Alternate mounting studs are provided for use with optional HST mounting
frame P/N 78-8062-4234-9. See parts drawing, page 26.
5.
The taping head assembly is provided with mounting holes for mounting the tape drum bracket in two
different locations. Normal installation is in the center of the frame. For clearance problems, the front
mounting can be used.
IMPORTANT SAFEGUARDS
Upper Taping Head
Refer to Figure 2-1 for mounting dimensions.
1.
Remove the (4) 5/16 – 18 slotted pins from the hex mounting studs.
2.
Install and secure the taping head using the (4) 5/16 – 18 tapped holes available in the hex mounting studs.
Lower Taping Head
1.
Install the taping head by lowering mounting pins into bed frame slots, or remove (4) 5/16 - 18 slotted pins
and use 5/16 – 18 tapped holes in the hex mounting studs.
Содержание 29100
Страница 10: ...6 Installation Figure 2 1 Taping Head Assemblies Typical Mounting Dimensions ...
Страница 12: ...8 THIS PAGE IS BLANK ...
Страница 20: ...16 THIS PAGE IS BLANK ...
Страница 22: ...18 Maintenance Continued Figure 6 1 Blade Replacement ...
Страница 26: ...22 THIS PAGE IS BLANK ...
Страница 28: ...24 THIS PAGE IS BLANK ...
Страница 29: ...25 Taping Head Assemblies HST 3 Inch Type 29100 ...
Страница 30: ...26 HST 3 Inch Type 29100 Figure 7 ...
Страница 32: ...28 Figure 8 HST 3 Inch Type 29100 ...
Страница 34: ...30 Figure 9 HST 3 Inch Type 29100 ...
Страница 36: ...32 Figure 10 HST 3 Inch Type 29100 ...
Страница 38: ...34 Figure 11 HST 3 Inch Type 29100 ...