GENERAL SAFETY INFORMATION

Intended Use

The 3M™ Portable Compressed Air Filter & Regulator Panel 256-02-00, with Carbon Monoxide
(CO) Filtration and Monitor is intended to filter and regulate compressed air to be used with
supplied air respiratory protection systems.  

List of Warnings and Cautions within these 

User Instructions

IMPORTANT

Before use, each person using this equipment must read and understand these 

User Instructions

.

Keep these 

User Instructions

for reference.  

Do Not Use For

Filtering and regulation of air sources when airborne contaminant concentrations are unknown or
immediately dangerous to life or health (IDLH), unless used in conjunction with a back-up escape
system or a self-contained breathing apparatus/supplied air respirator (SCBA/SAR), 
where applicable.  

The 3M™ Portable Compressed Air Filter & Regulator Panel 256-02-00, with Carbon
Monoxide (CO) Filtration and Monitor is intended to filter and regulate compressed air to be
used with supplied air respiratory protection systems.  

Misuse may result in sickness or death.

For proper use, see supervisor or 

User Instructions

, or call 3M in U.S.A., 1-800-243-4630.  In

Canada, call Technical Service at 1 800 267-4414.

The 3M™ Portable Compressed Air Filter and Regulator Panel 256-02-00, with CO Filtration
and Monitor should not be used when the air entering the filtering system is oxygen deficient.
These units will not increase the oxygen content of oxygen deficient air.  

Use with oxygen

deficient air may result in sickness or death

.

The panel should not be used in an Immediately Dangerous to Life or Health atmosphere
(IDLH) unless it is used in conjunction with a back-up escape system or a Self-Contained
Breathing Apparatus/Supplied Air Respirator (SCBA/SAR), where applicable.

To meet NIOSH requirement 42 CFR 84, subpart 84.150 for minimum and maximum airflow
(4-15 cfm, 113-425 lpm), the air control valves approved for use with the 3M respirators must
be operated within the supply pressure ranges and hose lengths stated in their 

User Instructions

.

Failure to do so may adversely affect respirator performance and result in sickness or death

.

You must comply with OSHA standard 29 CFR 1910.134, which states that, “Airline couplings
shall be incompatible with outlets for other gas systems to prevent inadvertent servicing of
airline respirators with nonrespirable gases or oxygen.”  In Canada, refer to the requirements of
CSA standard Z180.1.  

Failure to do so may result in sickness or death

.

Your employer must provide breathing air that meets at least the requirements of the
specification for Grade D breathing air, as described in the Compressed Gas Association
Commodity Specification G-7.1-1997 in the United States.  In Canada, refer to CSA standard
Z180.1, table for the quality of compressed breathing air.  

Failure to do so may result in

sickness or death

.

There is no assurance that by using the 3M™ Portable Compressed Air Filter and Regulator
Panel 256-02-00, with Carbon Monoxide Filtration and Monitor the filtered compressed air will
meet the requirements of Grade D breathing air.  In Canada, refer to the requirements of CSA
standard Z180.1.

The line pressure must be kept within safe limits, 125 psig (8.75 kg/cm

2

) maximum.  Dirt, oil

and water, unless trapped or filtered out, may continue downstream in concentrated form and
adversely affect the performance of the respirator and 

may result in sickness or death

.

The intrinsic safety of the carbon monoxide monitor is voided when remote alarm is used.

The intrinsic safety of the carbon monoxide monitor is voided when the 110-120 volt AC
adapter is used.

W

WARNING

Carbon monoxide monitor will alarm if carbon monoxide concentrations exceed the preset level
(10 ppm USA;  5 ppm Canada).  If alarm should sound, remove respirator or activate SCBA
and immediately move to a safe, breathable atmosphere.  Have the proper qualified personnel
examine the equipment and make the appropriate corrections before using again.  

Failure to do

so may result in sickness or death

.

Use of equipment described in these 

User Instructions

must be in accordance with applicable

health and safety standards, respirator selection tables contained in such publications as ANSI
Z88.2-1992, CSA Standard Z94.4, or pursuant to the recommendations of an industrial
hygienist.  The employer must have a written respirator program in place which is in
accordance with the OSHA respiratory protection standard found in 29 CFR 1910.134 prior to
using any respirator.  In Canada, follow CSA Standard Z94.4 or the requirements of the
authority having jurisdiction in your region.

Each person using this equipment must read and understand the information in these 

User

Instructions

.  Use of this equipment by untrained or unqualified persons, or use that is not in

accordance with these 

User Instructions

, may adversely affect product performance and 

result

in sickness or death

.

Do not use for respiratory protection when atmospheric concentrations of contaminants are
unknown or immediately dangerous to life or health, unless used in conjunction with a back-up
escape system or a self-contained breathing apparatus/supplied air respirator (SCBA/SAR).

Leave work areas immediately if:

– Any part of the system becomes damaged. 
– Air flow into the respirator is reduced or stops. 
– Breathing becomes difficult. 
– Dizziness or other distress occurs; or 
– You taste or smell contaminants or an irritation occurs.

Never alter or modify this assembly.

Not for use in any way other than in accordance with the use and maintenance instructions in
this manual.

Do not use if any parts are missing or damaged.

Air supply piping, fittings, and compressors must have the capacity to deliver sufficient air
volume to operate each air regulating valve at the recommended pressure.

Serious injury could result if the AIR SAMPLE METERING VALVE is not properly adjusted.
Proper sample airflow to CO monitor is required for monitor to give correct CO level readout.

Failure to do so may result in sickness or death

.

Always turn off air supply and bleed air pressure before disassembling the 3M filter and
regulator panel with CO filtration or 

serious injury could result

.

W

WARNING

34870214383  10/28/08  12:38 PM  Page 5

Содержание 256-02-00

Страница 1: ...r Building 235 2W 70 St Paul MN 55144 1000 3M Occupational Health and Environmental Safety Division 3M Canada Company P O Box 5757 London Ontario N6A 4T1 FOR MORE INFORMATION In United States contact...

Страница 2: ...Carbon Monoxide Filtration and Monitor 7 Replacement Parts 8 Accessories 8 Set Up Procedures 8 OPERATING INSTRUCTIONS 10 Carbon Monoxide Monitor 11 3M Portable Compressed Air Filter and Regulator 256...

Страница 3: ...he filtered compressed air will meet the requirements of Grade D breathing air In Canada refer to the requirements of CSA standard Z180 1 The line pressure must be kept within safe limits 125 psig 8 7...

Страница 4: ...cfm 1416 L min Inlet pressure recommended 90 120 psig 6 2 8 3 bar Outlet pressure range 0 125 psig 0 8 6 bar Operating temperature range 68 150 F 20 65 C compressed air temperature at inlet of panel 0...

Страница 5: ...e with the 3M respirators must be operated within the supply pressure ranges and hose lengths stated in their User Instructions Failure to do so may adversely affect respirator performance and result...

Страница 6: ...nts The filter and regulator panel comes with a 3M Carbon Monoxide Monitor designed to provide continuous direct read CO monitoring The carbon monoxide monitor in the filter and regulator panel is CSA...

Страница 7: ...th and safety standards respirator selection tables contained in such publications as ANSI Z88 2 1992 CSA Standard Z94 4 or pursuant to the recommendations of an industrial hygienist The employer must...

Страница 8: ...and outlet compressed air hoses Pressurize the system and set the regulator to the appropriate pressure required by the respirator air control device Adjust air sample metering valve s adjustment knob...

Страница 9: ...Refill the third stage aluminum tube by sliding the new third stage filter cartridge into the aluminum tube from the bottom Make sure that the flow direction arrow on the new third stage filter cartr...

Страница 10: ...ed in duration to the above one 1 and two 2 year periods respectively 3M shall not be liable for loss of use of any of its products or incidental or consequential costs expenses or damages incurred by...

Отзывы: