background image

www.3ko.hu 

Apollo micro-2 V6.04 

  [email protected] 

Functions of LED indications: 

 
When powering-on the green LED must light for a while, otherwise the pager is out of order. Then pager starts the self-examination 
taking up some minutes. After this procedure flash by seconds of green LED will indicate the ready-to-operating status. 
The summary of possible LED indications :  
 
Green LED:   

 Flashing by seconds – normal operation 

 

 

  Continuous light – incoming or outgoing call or SMS 

 

 

  Quick flashing -  PC connected , ready to download 

 
Yellow LED:  

Indicator of active relay 

 

 

   

Red LED:       

 Separated short flashes in case of Errors, as follows: 

 

1 flash   

phone call was unsuccessful (e.g. the number is busy or out of order) 

 

2 flashes 

SMS messaging was unsuccessful 

 

3 flashes 

signal strength problem 

 

4 flashes 

internal GSM communication errors, automatic restart will follow 

 

5 flashes 

SIM-card phone-book records are unreadable or faulty 

 

 
Recording SMS messages to SIM-card, using mobile phones 

 

There are three kind of  predefinable SMS text messages, which will be ready to send in case of different events. 

Delete all incoming, outgoing and predefined SMS messages from SIM, before recording the new messages. 

 

Record the SMS #1 message, it will be sent in case of  triggering the positive input 

 

Record the SMS #2 message, it will be sent in case of triggering the negative input  

 

Record the SMS #3 message, it will be sent in case of restoring the positive input 

The neccessary condition to send any SMS is to register the appropriate keywords  (Possms, Smstel…). 
 
Recording of predefined SMS messages could be done by inserting the SIM into a mobile phone, writing-in the messages using the 
keypad, then puting back the SIM into pager. Other method is to write-in the messages into a mobile, then sending the three SMS in 
proper order to the pager. Prior to this operation the pager’s SMS memory must be empty  - for this reason use a remote control SMS 
to delete SMS fields in the pager (see keyword Psw) 

 
Programming keywords and parameters 

 

Altel1, Altel2,Altel3, Altel4 

 
The data related to these keywords are the phone numbers which will be dialed by pager when negative input was triggered. 
It is not obligatory to insert these keywords, their number is optional. If only SMS message is required, do not insert any of them.  The 
module will interpret a dialing as a successful call, if the target number will pick up the line. If the call is unsuccessfull, the module 
later will repeat the paging to the same number (see Recall keyword). 
 

Bitset  

(6 binary digits, if the record is missing then default value is : 100000)

 

 

The data related to this keyword is a numeric string of 6 digits, interpreted as follows: 

 

 

1. digit:   

0

 – positive input will trigger when released from supply 

 

 

 

1

 – positive input will trigger when switched to supply 

 

 

2. digit:   

0

 – negative input will trigger when switched to GND 

 

 

 

1

 – negative input will trigger when released from GND 

 

 

3. digit   

0

 – relay operation is bistable, for each call its status will be changed to opposite  

 

 

 

1

 – relay operation is monostable, for each call the relay will active for defined seconds 

 

 

4. digit   

0

 – in case of  SMS command to relay control, the module will pick up the line, and will answer 

 

 

 

 

with an audio signal (three beeps = Switch-ON / one beep = Switch-OFF) 

Содержание Apollo Micro-2

Страница 1: ... time in the phone book exeptions Cl parameters First letter of all keywords must be a capital It is not neccessary to define all possible keywords It is not allowed to insert a keyword without related data Phone numbers have to use international format starting with country code Phone number length is max 15 characters Switch OFF PIN code protection Switch ON number display for incoming calls Set...

Страница 2: ...tel Recording of predefined SMS messages could be done by inserting the SIM into a mobile phone writing in the messages using the keypad then puting back the SIM into pager Other method is to write in the messages into a mobile then sending the three SMS in proper order to the pager Prior to this operation the pager s SMS memory must be empty for this reason use a remote control SMS to delete SMS ...

Страница 3: ...r other special SMS can generate bigger cost for the users Newcall 5 240 min if the record is missing then default is 10 min The data related to this keyword is the new call delay time in minutes the time between two consecutive new calls the pager waiting after a triggering before accepting a new event from the negative input line and starting a new call to the target number This parameter could ...

Страница 4: ... trials Relay 1 250 sec if the record is missing then default is 2 sec Time in seconds being the relay in active status in monostable mode Ringing 10 240 sec if the record is missing then default is 40 sec The data related to this keyword is the time duration in seconds permitted for ringing the target number Passing this time the pager will finish the ringing by interpreting it an unsuccessful ca...