Pag. 5
Instruction Manual BSE-150
ENGLISH
Replace the front cover and test if
the active infrared barrier is functio-
ning correctly. If not,it must be
recalibrated.
NOTE: The more precise is the
alignment, the more intense will
be the luminosity of the Red
Led. It is best to regulate the
sensor until the luminosity is at
a maximum.
Testing with voltmeter
1. Insert the tester cable points
based on the polarity in the
holes marked (+ and -)
2. Regulate the vertical and
horizontal angles until the
voltage is at a maximum.
Visual test
1. Remove the front cover and
power up both receiver and tran-
smitter.
2. Align the beams between the
transmitter and receiver.
3. On the riceiver, by using the
vertical and horizontal alignment
tools, you may better align the
receiver and the transmitter.
See below.
4 - Alignment of the I.R.
For
the
horizontal
regulation, rotate the
lens body as desired.
Riceiver
Vertical regulation
screw.
Low
High
Left
Right
10 9 8 7 6 5 4 3 2 1
RECEIVER