4/4
3DGence ONE | support: +48 32 438 98 64 | www.3dgence.com
01.2018
3DGence ONE
11
Check if the distance in all four corners is 0.8 mm by manual movement of the heatbed and the hotend to all corners.
– base Z axis in order to check the location of the nozzle by using the
Home Z
command,
– check the distance between the nozzle and the heatbed using the feeler (or credit card). It should be 0,8 mm,
– repeat these steps until the distance between the nozzle and the heatbed will be 0.8 mm.
– if the distance is maintained, tighten the screw from Z-axis slider (1) and again check the distance in all corners.
Then run Heatbed Scan by choosing the following commands from printer’s menu:
OK Calibration Heatbed Scan
– if the distance is not within the range of 0.7 mm to 0.9 mm – contact the 3DGence service.
Z-AXIS LIMIT SWITCH ADJUSTMENT