background image

Z-AXIS LIMIT SWITCH ADJUSTMENT

3DGence ONE

Service manual:

Содержание ONE

Страница 1: ...Z AXIS LIMIT SWITCH ADJUSTMENT 3DGence ONE Service manual ...

Страница 2: ...supply in order to avoid electric shocks 1 4 01 2018 1 Remove filament from the hotend by choosing following commands from printer s menu OK Prepare Unload filament 4 Check if the screws are tightened under the heatbed 5 Loosen the screw from Z axis slider 1 and use knurled bolt 2 to lower a slide a few millimeters clockwise in order to move the hotend from the heatbed for safety WARNING Screwing th...

Страница 3: ...ure to 75 C and wait 10 minutes to warm up the heatbed and stabilize the temperature 8 Distort the printer by choosing following commands from printer s menu OK Configuration Hardware Test Home Z 7 Move the heatbed to the back move the X axis rail block to the base position to the left position in such manner that the hotend does not rise above the heatbed for safety Z AXIS LIMIT SWITCH ADJUSTMENT ...

Страница 4: ...t card It should be 0 8 mm when the distance is more or less than 0 8 mm adjust it manually using the knurled bolt turn the knurled bolt in the appropriate direction we recommend not more than a half of turnover for safety 9 Move the heatbed slowly to the front to such position that the hotend is above the front left corner of the heatbed be careful so the heatbed do not hit the hotend hotend shou...

Страница 5: ...en the nozzle and the heatbed using the feeler or credit card It should be 0 8 mm repeat these steps until the distance between the nozzle and the heatbed will be 0 8 mm if the distance is maintained tighten the screw from Z axis slider 1 and again check the distance in all corners Then run Heatbed Scan by choosing the following commands from printer s menu OK Calibration Heatbed Scan if the dista...

Отзывы: