3D Systems ProX Скачать руководство пользователя страница 13

 

3D Systems, Inc. 

p/n 77-D005 Rev_A

 

Burns 

This equipment contains high temperatures and burning laser radiation which could cause 2

nd

 degree burns . Do not attempt to 

remove any protective panels . There are no user serviceable parts inside . 

If a burn occurs, seek first aid and immediate medical attention. Pushing the E-stop button will de-energize the equipment and 

diffuse the hazardous situation . 

Electrocution 

The SLS system contains equipment energized at 208 volts, 3-phase delta . Do not attempt to remove protective panels . There 

are no user serviceable parts inside . 

If electrocution occurs, seek first aid and medical attention immediately. Pushing the E-stop button will de-energize the 

equipment and diffuse the hazardous situation . 

Material Inhalation 

The part cleaning process may create a choking or air restriction hazard. If someone has difficulty breathing or a “loss of 

breath” sensation, transport the person to a well-ventilated room or outside of the facility . If the condition persists, seek 
immediate medical attention . 

SLS EQUIPMENT SAFETY FEATURES 

A major design goal for all SLS equipment is to provide a safe operating environment . The frame and enclosure designs 

passively limit hazardous access while the electronics and software actively and automatically sense and react to unsafe 
conditions when they arise . For example, if the SLS system detects unsafe operating conditions, it will immediately stop 
operating and, in some cases, shut down completely . 

CAUTION: If any SLS equipment safety features fail, your actions may be all that will prevent 
potentially hazardous operating conditions.

 

Safety Interlocks 

Safety interlock devices on the SLS equipment help prevent accidental laser exposure, electrical shocks, crush injuries, burns, 

and fires. SLS equipment will not operate unless all safety interlocks are satisfied. 

CAUTION: Never try to disable or override any safety interlock device on any SLS equipment. 
Operating equipment without all safety interlocks enabled can cause equipment damage, injury, or 
death. If you suspect a safety interlock device is not working properly, do not operate your SLS 

equipment. Rather, disconnect power from the equipment and contact 3D Systems Customer Support for 
assistance.

 

a. Internal panels are for service access only. Several interlocked panels are for customer maintenance: overflow cleanout, 

blackbody cleaning port, and the filter box located on back of machine. 

Limited Access and Barrier Shielding 

SLS equipment frame and enclosure designs limit access to the following: 

• 

Service areas

, such as cabinets and enclosures for electrical power and automation controls. This prevents 

accidental exposure to electrical shock hazards.

 

• 

Material areas

, such as material feed hoppers, storage bins, and transport tubes. This prevents:

 

• 

burn hazards by minimizing exposure to heated material

 

• 

slip hazards by keeping material from dropping on the floor

 

• 

fire hazards by minimizing airborne dust cloud formation and potential ignition. See SDS for complete 
material hazard details.

 

Содержание ProX

Страница 1: ...SLS SINGLE USE MQC SYSTEM User Guide Original Instructions ...

Страница 2: ...le Use System User Interface 4 ProX MQC Single Use System Stack Light Conditions 4 Fresh Material Input 5 3 SAFETY GUIDELINES INSTRUCTIONS 6 General Guidelines 6 Training and Instructions 6 Machine Handling 6 Material Handling 6 Alarms and Warnings 6 Safety Symbols and Definitions 7 First Aid Section What to do 7 Burns 7 Electrocution 7 Material Inhalation 7 SLS Equipment Safety Features 8 Safety ...

Страница 3: ...xygen Deprivation Effects and Symptoms 12 4PROX MQC SINGLE USE SYSTEM OPERATIONS 13 How the prox MQC single use System Works 13 Receiving and Storing Material 13 Blending and Sending Material 13 Basic Operations 13 Turning on the ProX MQC Single Use System 13 Shutting Down the ProX MQC Single Use System Completely 14 Cleaning the ProX MQC Single Use System Before Breakout 14 i Verifying Material Q...

Страница 4: ...screen 20 First line display may change based on MQC current status 20 ProX MQC Single Use System Main Control Screen 20 Operational Mode Screen 21 To Load Fresh Powder 21 To change Replenish percentage 22 Diagnostics Screen 24 Setup Screen 24 Material Tracking Screen 24 Fresh Bin Diag Screen 25 Blend Bin Diag Screen 25 Sifter Diag Screen 26 Generic I O Diag Screen 26 5 PROX MQC SINGLE USE SYSTEM ...

Страница 5: ...3D Systems Inc p n 77 D005 Rev_A ii ...

Страница 6: ...d maintain your ProX Material Quality Control MQC System used for the SLS process For part printing instructions refer to the Material Guide for your specific material WHAT S INSIDE MQC System Operations This section details the operation of the MQC System including part breakout Safety Guidelines and Instructions The Safety section tells you what you need to know to avoid injury or equipment dama...

Страница 7: ...nables and disables power to the ProX MQC Single User System Blended Material Bin Material which is a combination of used material and fresh material is stored for production use in this hopper The system handles this automatically Fresh Material Input Fresh material is loaded at this location The user must scan the RFID tag on the container across the RFID reader RFID Reader The RFID reader is us...

Страница 8: ...eaking out the parts Nitrogen Blanket This lid is placed on top of a filled print cake cylinder to control the cooldown of the print cake using nitrogen Stowaway Area Underneath the breakout area there is a space which can be used to store part extraction cylinders when they are not in use Sifter The user removes the parts from the print cake in the breakout area and places the material for reuse ...

Страница 9: ...Nitrogen Pressure Regulator Air Pressure Regulator Air Transport Filter The material filter for the ProX MQC Single Use System PROX MQC SINGLE USE SYSTEM COMPONENTS ProX MQC Single Use System User Interface The User Interface located on the front panel of the ProX MQC Single Use System consists of a dial operated menu screen that allows the user to access the functionality of the system An E Stop ...

Страница 10: ...ns on the LED Display using this dial control ProX MQC Single Use System Stack Light Conditions Fresh Material Input The material input hatch takes fresh material from the user and feeds it to the ProX MQC Single Use System To unlock the hatch the user must first swipe the tag of the material container across the tag reader Light Color Solid Flashing Off Red E Stop condition System fault active No...

Страница 11: ...ith all materials supplied by 3D Systems All SLS equipment is designed with safety in mind However improper use malfunctions and excessive exposure could cause injury TRAINING AND INSTRUCTIONS Follow these general safety guidelines when operating any SLS equipment Do not operate any SLS equipment before receiving proper training Read and follow all operating instructions Follow all safety rules in...

Страница 12: ...e Material Guide ALARMS AND WARNINGS If you see an error alarm or warning message on any SLS equipment display note the state of that machine s stack light Clear the alarm error or warning message before resuming operation Displayed error alarm or warning messages can result from unsafe practices such as opening an enclosure door or panel when equipment is powered up and running SAFETY SYMBOLS AND...

Страница 13: ...diately stop operating and in some cases shut down completely CAUTION If any SLS equipment safety features fail your actions may be all that will prevent potentially hazardous operating conditions Safety Interlocks Safety interlock devices on the SLS equipment help prevent accidental laser exposure electrical shocks crush injuries burns and fires SLS equipment will not operate unless all safety in...

Страница 14: ...ain unsafe conditions are detected during operation ELECTRICAL SAFETY To prevent electrical shock SLS equipment will not operate unless all external panels are installed and all electrical safety interlock circuits are closed ELECTRICAL HAZARD Hazardous voltage exists inside the enclosures of all SLS equipment Injury or death from electrical shock can result if you remove external panels or try to...

Отзывы: