68
3D SYSTEMS, INC
.
PN:80-D27 Rev.B
6
USER MAINTENANCE
Described here are the servicing and preventive maintenance procedures that are required in the day to day operation of
the ProX DMP 300 printer . The following safety rules are applicable for all procedures .
Caution : the machine is not allowed to run a job during a maintenance .
Caution : perform only tasks you are authorized and certified to complete.
Caution : presence of metal powder. Do not use or manipulate any material without first reading the
safety datasheet (SDS) for that specific material.
Caution : Personal Protective Equipment (PPE) must be used to protect the user against health or
safety risks during working tasks . Wear disposable rubber gloves, anti-static coverall, anti-static safety
shoes and safety glass . Wear disposable dust mask rated FFP3 or N99 level protection at minimum ; we
recommend the use of powered air-purifying respirator .
WARNING : FINE METAL DUST IS HIGHLY FLAMMABLE . AVOID USING ANY IGNITION SOURCE NEAR THE
MACHINE (OPEN FLAME, SPARKING, ELEVATED TEMPERATURE PARTS) .
SERVICING : REPLACEMENT FILTERS PROCEDURES
ITEM
SPECIFICATION
ONCE A
MONTH
1500
HOURS
Filters
Recycling
Replace
X
External Filter
vessel
Replace
X
Recycling filter and vacuum filter replacement
These filters must be changed
once a month .
Part:
•
Filter element (part number : 1002235T00)
Procedure :
1 . Make sure the recycling and the vacuum cleaner are not running .
2 .
For the recycling filter, open the left side acess door. For the vacumm filter, open the right side acess door.
When the side door is opened, the status of the interlock prevents the printer to operate during the
maintenance (see "DMP System Response if an Interlock Fails" on page 9) .
4 . Open the access door .
5 .
Loosen the filter and remove it from the module. Make sure to fully loosen the locking system to avoid any damage on
the seal during the filter removal.
6 .
Dispose of filter in accordance with all local/national, state and federal regulations.
WARNING : FLAMMABLE POWDERS .
PLACE THE USED FILTER IN A CLOSED METALLIC CONTAINER IN A ROOM WITH FIRE DETECTION .
7 .
Insert the new clean filter without rotating it, making sure it is correctly positioned, centered in the slot and tightened.
8 . Close the access door .
9 . Reset the corresponding timer : see section "Machine Status menu" on page 50 for details .