VCX Server
Response to Power
Events
This section describes how UPS-supported VCX systems respond to
various power events.
Power events and VCX server responses are shown in
.
Table 11
VCX Server Behavior for Power Events
Event
Response
Power Loss
When one or more VCX servers are connected to a UPS and
a power loss occurs, the servers continue to operate without
interruption. The servers do not initiate a shutdown unless
the UPS battery power level is below the threshold capacity
for shutdown (for example, because the UPS battery has not
yet fully recharged after a prior power loss event).
A power loss event is detected by VCX software, logged
through syslog, and reported as an SNMP trap.
Power Restoration
Prior to Depleted
Battery
If power returns while a VCX server is operating on UPS
battery power, the VCX server:
■
Logs the event through syslog.
■
Generates an SNMP trap indicating return of power.
■
Resumes normal operation.
Depleted Battery
Each UPS is configured with a battery threshold. The
threshold charge is expressed as a percentage of remaining
battery power. The default is 25%. When the UPS battery
reaches the configured threshold, a VCX server:
■
Logs this event through syslog.
■
Generates an SNMP trap indicating that shutdown is
imminent.
■
Starts an orderly shutdown of services and the VCX
operating system.
If the VCX system has multiple UPS devices providing power,
the depleted battery event occurs only when
both
UPS
devices are running on battery and are at or below the
low-battery threshold.
Содержание VCX V7000
Страница 26: ...26 CHAPTER 1 VCX SYSTEM MAINTENANCE OVERVIEW ...
Страница 68: ...68 CHAPTER 3 MANAGING VCX SERVERS ...
Страница 78: ...78 CHAPTER 4 BACKING UP AND RESTORING A VCX CONFIGURATION ...
Страница 88: ...88 CHAPTER 5 MANAGING AUTHENTICATION AND DIRECTORY SERVICE DATABASES ...
Страница 100: ...100 CHAPTER 6 MANUALLY CONFIGURING MULTI MASTER REPLICATION ...
Страница 140: ...140 CHAPTER 8 MANAGING UNINTERRUPTIBLE POWER SUPPLIES ...
Страница 250: ...250 APPENDIX B UPGRADING VCX SERVER SOFTWARE FROM V7 1 X TO V7 1 Y ...
Страница 290: ...290 APPENDIX C UPGRADING VCX SERVER SOFTWARE FROM V6 0 TO V7 0 ...
Страница 328: ...328 APPENDIX D DOWNGRADING VCX SERVER SOFTWARE ...
Страница 339: ...CLI Command Descriptions 339 ...