Connectors and Cables
2-7
STP Connector and Cable
The following figure shows the pinouts of the STP connector (DB-9).
The connector bodies connect the cable shield to chassis ground.
Table 2-2 lists cable types, multistation access units (MAUs), and
emissions classes compatible with the STP connector.
* Shielding of all cable types should be terminated 360 degrees at the cable plug.
† All UTP compliance testing was accomplished using cables built with Stewart Connector Co.
connector, part number 940 SP-36-08-08.
* Shielding of all cable types should be terminated 360 degrees at the cable plug.
Table 2-2
UTP Cable Types, MAUs, and Emissions Compliance
MAUs
Emissions Compliance
*
Cable Type
Passive
Active
Retimed
FCC and
VCCI Class A
EN55022 and
VDE Class B
UTP
†
100 ohm:
Category 3
no
yes
yes
no
Category 4
yes
yes
yes
no
Category 5
yes
yes
yes
no
Shielded
UTP
†
100 ohm:
Category 3
no
yes
yes
yes
Category 4
yes
yes
yes
yes
Category 5
yes
yes
yes
yes
Table 2-3
STP Cable Types, MAUs, and Emissions Compliance
MAUs
Emissions Compliance
*
Cable Type
Passive
Active
Retimed
FCC and
VCCI Class A
EN55022 and
VDE Class B
STP
150 ohm:
IBM Type 1
yes
yes
yes
yes
IBM Type 6
yes
yes
yes
yes
5
9
8 7 6
4 3
2
1
STP
1 RX
2 GND
3 +5 V
4 GND
5 TX
6 RX
7 GND
8 GND
9 TX
DB-9 female (shielded)
SS2TRHWBook Page 7 Monday, May 5, 1997 3:11 PM
Содержание SuperStack II 32x
Страница 8: ...viii SS2TRHWBook Page viii Monday May 5 1997 3 11 PM...
Страница 10: ...2 CHAPTER ABOUT THIS GUIDE SS2TRHWBook Page 2 Monday May 5 1997 3 11 PM...
Страница 44: ...2 22 CHAPTER 2 OVERVIEW SS2TRHWBook Page 22 Monday May 5 1997 3 11 PM...
Страница 48: ...3 4 CHAPTER 3 UPGRADING MEMORY SS2TRHWBook Page 4 Monday May 5 1997 3 11 PM...
Страница 64: ...A 10 APPENDIX A PROVISIONING YOUR ISDN LINE SS2TRHWBook Page 10 Monday May 5 1997 3 11 PM...
Страница 70: ...SS2TRHWBook Page 6 Monday May 5 1997 3 11 PM...
Страница 74: ...4 INDEX SS2TRHWBook Page 4 Monday May 5 1997 3 11 PM...