NAC LED indicators

Correcting NAC

alarms and/or error

conditions

Refer to the NAC’s Product Reference for additional hardware trouble 
clearing information. The NAC’s user interface (UI) console has status 
screens that supply information on power-up self tests and card status.

Physical State

Carrier 
LED 
State

Alarm 
LED State

Loop back/ 
D-channel 
LED State

Condition/Physical State

F1

Green

Off

Off

No Alarm

F2

Red

Off

Off

Yellow Alarm
Remote Frame Alarm

F3

Off

Red

Off

Red Alarm
Loss of Signal

F4

Off

Red

Off

Red Alarm
Out of Frame

F5

Green 

Red

Off

Blue Alarm
Unframed all ones

F6

Red

Red

Off

CRC & RAI

Amber

D-Channel down

Green

Off

Green

Loop Back in Progress

Alarm/Error

Level

Diagnosis/Trouble Clearing

Remote Frame 
Alarm

Yellow

The remote end has lost the HiPer DSP’s framing or 
signal and sends this alarm to the HiPer DSP.

Loss of Signal

Red

The received T1 or E1 signal has been lost. The HiPer 
DSP declares a red alarm and sends a yellow alarm to 
the remote end. 

Out of Frame

Red

The received T1 or E1 framing has been lost and the 
framed payload can no longer be received. The HiPer 
DSP declares a red alarm and sends a yellow alarm to 
the remote end. 

Unframed all 
ones

Blue

The remote end is sending out an all ones signal. This is 
usually done when the remote end can not send out a 
framed signal.

RFA and 
Continuous 
CRC errors

N/A

The HiPer DSP has received excessive CRC errors in a 
one second period and declares state F5. For E1-PRI 
certification this is less than 931 errors in one second. 

Содержание HiPer DSP

Страница 1: ...HiPer DSP Network Application Card Getting Started Guide Part No 1 024 1325 01...

Страница 2: ...http www 3com com HiPer DSP Network Application Card Getting Started Guide Part No 1 024 1325 01...

Страница 3: ...nical data and computer software is commercial in nature and developed solely at private expense Software is delivered as Commercial Computer Software as defined in DFARS 252 227 7014 June 1995 or as...

Страница 4: ...TECHNICAL SPECIFICATIONS Trouble Clearing A 1 NAC LED Indicators A 2 Correcting NAC alarms and or error conditions A 2 Technical Specifications A 3 Certification A 3 T1 HiPer DSP A 3 E1 HiPer DSP A 3...

Страница 5: ...oll Free Number Country Toll Free Number Austria 06 607468 Netherlands 0800 0227788 Belgium 0800 71429 Norway 800 11376 Canada 1800 2318770 Poland 00800 3111206 Denmark 800 17309 Portugal 0800 831416...

Страница 6: ...y or fatality May also alert you to potential electrical hazard ESD Information to alert you to take proper grounding precautions before handling a product Convention Description Text represented as a...

Страница 7: ...e that supports E1 applications such as E1 PRI and E1 CAS The HiPer DSP for T1 applications contains 24 modems while the E1 version has 30 Together with the HiPer DSP T1 E1 Network Interface Card NIC...

Страница 8: ...in the Total Control chassis you need a 2 Phillips and flat head screwdriver Installation Procedure To install this NAC ESD To reduce the risk of electrostatic discharge ESD take proper grounding pre...

Страница 9: ...NIC CH1 Port Rate DIP1 OFF OFF ON ON DIP2 OFF ON OFF ON SELECTS 9600 bps 19200 bps 38400 bps Reserved 3 CH T1 OFF Hardware Flow Control disabled ON Hardware Flow Control enabled T1 PRI Reserved E1 PRI...

Страница 10: ...chassis 3 Select a slot at the front of the Total Control chassis for installing the NAC Install this NAC in slot s 1 17 For managed chassis slot 17 is reserved for the Network Management Card NMC NA...

Страница 11: ...AC between the slot s upper and lower card guides 6 Holding the tabs perpendicular to the NAC s front panel slide the NAC into the chassis until the front of the NAC is flush with the chassis Push the...

Страница 12: ...chassis if power is not already applied 10 After the NAC boots verify that the RN FL run fail LED is green If the RN FL LED does not light is solid red or flashing red there is an error Refer to the T...

Страница 13: ...e NIC or the span options are not configured properly 1 Verify that your NIC is installed correctly and that the span is connected to the NIC properly 2 Consult the HiPer DSP Product Reference to veri...

Страница 14: ...wn Green Off Green Loop Back in Progress Alarm Error Level Diagnosis Trouble Clearing Remote Frame Alarm Yellow The remote end has lost the HiPer DSP s framing or signal and sends this alarm to the Hi...

Страница 15: ...equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause...

Страница 16: ...g Physical Dimensions Board Manager System PowerPC RISC CPU Application Co Processor System Dual PowerPC RISC CPUs TI HiPer DSP NAC 5 2 VDC 4 3A typical maximum E1 HiPer DSP NAC 5 2 VDC 4 8A typical m...

Страница 17: ...3Com Corporation 5400 Bayfront Plaza P O Box 58145 Santa Clara CA 95052 8145 1999 3Com Corporation All rights reserved Printed in the U S A Part No 1 024 1325 01...

Отзывы: