60
C
HAPTER
9: T
ROUBLESHOOTING
To Run the NIC Test
Run the NIC test to check the physical components, connectors, and circuitry on
the NIC.
To run the NIC test:
1
Click
Run NIC Test
on the Diagnostics (tab) screen.
The NIC Test screen appears.
2
Click
Perform NIC Test
.
While the test is running, a progress bar indicates test progress.
If the test fails, a message indicates the error type. Click the
Help
button in the
error message screen to obtain more information.
If the test passes, the NIC is functioning correctly.
3
Click
Close
.
To Run the Remote
Wake-Up Test
You need at least two PCs on your network that contain a 3Com NIC with
EtherDisk 4.0
(or later) or
EtherCD
Version 1.0 for the 3CR990 Family
software
to run the Remote Wake-Up test.
To run the Remote Wake-Up test:
1
On the first PC, enable Auto Echo:
a
Open the 3Com NIC diagnostics program and make sure that Auto Echo is
enabled on the General screen.
b
Close the 3Com NIC diagnostics program.
c
Make sure that the PC remains powered on and connected to the network.
2
On the second PC, run the Remote Wake-Up test.
To run the Remote Wake-Up test on the second PC:
1
Click
Run Remote Wakeup Test
on the Diagnostics screen.
The Remote Wake-Up test screen appears.
2
Click
Test Remote Wake Up
to verify that another PC exists on the network that
has the
EtherDisk 4.0 (
or later) or
EtherCD
Version 1.0 for the 3CR990 Family
software and that Auto Echo is enabled on that PC.
If the test passes, another PC with the Auto Echo feature enabled was detected on
the network.
If the test fails, another PC with the Auto Echo feature enabled was
not
detected
on the network. You will not be able to run the Remote Wake-Up test (the
Remote Wake Up Restart
button will be unavailable).
3
Enter the number of seconds in the
Seconds Until Wakeup
entry box that the PC
remains shut down until it receives a wake-up packet from the first PC.
NOTE:
If the Run Remote Wakeup Test button is not available, either the NIC
that is installed in the PC does not support Remote Wake-Up or Magic Packet
is not enabled.
Содержание EtherLink 10
Страница 8: ......
Страница 22: ...22 CHAPTER 3 NIC INSTALLATION PCI 2...
Страница 23: ...Installing the NIC 23 3 Remote Wake Up Cable 3A 2 1 PCI specifications compliant...
Страница 24: ...24 CHAPTER 3 NIC INSTALLATION 4 TX DATA ACT 10 100 L N K 5...
Страница 26: ......
Страница 38: ......
Страница 74: ......
Страница 84: ......