Configuring Software
3-3
Difficulties in connecting are usually the result of mis-matched baud rates
between the NAC and the terminal emulator.
The Dual DSX-1 NIC’s configurable parameter is accessed differently
depending if it is installed behind the Channelized T1-386 or the T1/PRI
NAC.
Channelized T1-386 NAC
1
From the Main Menu, select option 5 <or 7>,
T1 Span Line 1 <2>
Configuration
.
This screen displays:
2
Select option 7.
This screen displays:
T1 Span Line 1 Configuration
Current Setting
1 T1 Span Line 1 Framing Mode
SF
2 T1 Span Line 1 Line Coding
AMI
3 T1 Span Line 1 Remotely Initiated Loopback Ignore
4 T1 Span Line 1 Jitter Attenuation
Receiver
5 T1 Span Line 1 Automatic Busy-out
Disabled
6 T1 Span Line 1 Fractional T1 Byte Pattern
FE Hex
7 T1 Span Line 1 Short Haul NIC Line Length 0-133
(NOTE: Changing configuration parameters may affect calls in
progress.)
Enter menu selection and press Return or press Esc to exit.
Menu Selection (1-7):
T1 Span Line 1 Short Haul NIC Line Length
1 0-133 feet
2 134-266 feet
3 267-399 feet
4 400-533 feet
5 534-655 feet
Enter menu selection and press Return or press Esc to exit.
Menu Selection (1-5):