Setting Up the Switch Clock Source
119
Example
Enter:
1 8 2 5.1.2
The following message is displayed:
External clock source port 1 was successfully configured to
port 5.1.2.
Set External Clock
Source 2
Set a port to be the second external clock source port. If the port does
not exist, is disabled, is in loop timing mode, loopback or loop forward, it
cannot be used as an external clock source port.
Command Actions
Command Result
If the port has already been set to be the first or second clock source, it is
meaningless to set the port again. In this case, the command is ignored
and the following message is displayed:
Clock source 1 is already set to this port.
It is meaningless to set the two sources to the same port,
operation ignored.
Enter menu sequence:
(1) SYS: Platform Configuration
(8) SCS: Switch Clock Synchronization
Setup
(3) SP2: Set External Clock Source 2
Enter parameter at prompt
Parameter
Format or Range
Clock source
<slot.group.port> or
None
Direct access sequence:
1 8 3 [parameter]
System action:
The port is set to be the active clock source port.
System message display:
External clock source port 2 was
successfully configured to port
<slot.group.port>.
Содержание CoreBuilder 9000
Страница 18: ......
Страница 36: ...36 CHAPTER 1 OVERVIEW...
Страница 44: ......
Страница 152: ...152 CHAPTER 6 MANAGING NETWORK INTERFACES...
Страница 224: ...224 CHAPTER 8 VIEWING STATISTICS...
Страница 306: ......
Страница 320: ...320 CHAPTER 10 ATM NETWORK BASICS...
Страница 332: ...332 CHAPTER 11 NETWORK INTERFACE MANAGEMENT...
Страница 348: ...348 CHAPTER 12 E IISP PROTOCOL...
Страница 374: ...374 CHAPTER 14 ATM SWITCHING...
Страница 410: ...410 CHAPTER 16 TRAFFIC MANAGEMENT...
Страница 426: ......
Страница 450: ...450 APPENDIX D TECHNICAL SUPPORT...
Страница 454: ...454 GLOSSARY...