background image

106

A

PPENDIX

 A: S

AFETY

 I

NFORMATION

Never look at the transmit laser while it is powered on. Never look directly 
at the fiber TX port and fiber cable ends when they are powered on.

WARNING: 

This device has more than one power input. Disconnect all 

power inputs to power off this device.

WARNING: 

The installation of the Redundant Power Supply (RPS) should 

only be carried out by properly trained and qualified personnel.

WARNING: 

These instructions must be read in conjunction with the RPS 

flyer and the safety and installation instructions supplied with your RPS.

WARNING: 

When powering any Switch 5500 from an RPS, the unit must 

be earthed (grounded). This can be achieved by either connecting the 
power cord to the unit or by connecting the earth terminal on the rear of 
the unit to a reliable electrical earth, or by connecting both. It must be 
ensured that the earth connection is made before connecting the DC 
supply from the RPS.

WARNING: 

Any RPS must be approved as an unearthed SELV output in 

accordance with IEC 60950-1/UL 60950-1/EN 60950-1.

WARNING: 

The characteristics of the Switch 5500 DC supply input are 

given in Appendix C on page 127.

WARNING:

 RPS Manufacturers recommendations must be followed 

when connecting the cable to the RPS.

WARNING: 

Ensure that the circuit breaker in the RPS is in the open (off) 

position when connecting the cable to the RPS. 

WARNING: 

You must ensure that the positive terminal on the switch is 

connected to the positive (common) terminal of the RPS and that the 
negative terminal on the switch is connected to the negative (circuit 
breaker) terminal of the RPS.

WARNING: 

Ensure that the circuit breaker in the RPS is in the open (off) 

position when connecting the RPS cable and connector to the switch.

Class 1

LASER PRODUCT

Содержание 5500-EI Series

Страница 1: ...3Com Switch 5500 Family Getting Started Guide Switch 5500 EI Switch 5500G EI www 3Com com Part No 10014925 Rev AD Published August 2007...

Страница 2: ...252 227 7015 Nov 1995 or FAR 52 227 14 June 1987 whichever is applicable You agree not to remove or deface any portion of any legend provided on any licensed program or documentation contained in or d...

Страница 3: ...gs 27 2 INSTALLING THE SWITCH Package Contents 30 Choosing a Suitable Site 31 Rack mounting 32 Connecting a Redundant Power Supply 35 Installing and Removing the Power Module 42 Placing Units On Top o...

Страница 4: ...ing Communication Problems 84 Solving Fabric Formation Problems 86 6 UPGRADING SOFTWARE The Contents of the Executable File 88 Upgrading from the Command Line Interface 88 Upgrading from the Bootrom I...

Страница 5: ...SUPPORT FOR YOUR PRODUCT Register Your Product 141 Purchase Value Added Services 141 Troubleshoot Online 142 Access Software Downloads 142 Telephone Technical Support and Repair 142 Contact Us 143 E 3...

Страница 6: ...6 CONTENTS...

Страница 7: ...91 Switch 5500 SI 52 Port 3CR17152 91 Switch 5500 EI 28 Port 3CR17161 91 Switch 5500 EI 52 Port 3CR17162 91 Switch 5500 EI PWR 28 Port 3CR17171 91 Switch 5500 EI PWR 52 Port 3CR17172 91 Switch 5500 E...

Страница 8: ...features supported by your Switch and how you can use them to optimize your network Switch 5500 Family Quick Reference Guide This guide contains a list of the features supported by the Switch 5500 Fa...

Страница 9: ...urrent software release including new features modifications and known problems The Release Notes are supplied in hard copy with your Switch Accessing the Documentation The Switch 5500 Family document...

Страница 10: ...llowing information when commenting Document title Document part number and revision on the title page Page number if appropriate Example Part Number 10014925 rev AC Switch 5500 Family Getting Started...

Страница 11: ...ory information about the Switch 5500 and how it to use it within a network It includes hardware and software feature summaries and contains the following section About the Switch 5500 Family Switch 5...

Страница 12: ...5500 to any 3Com system as your network grows Switch 5500 Family 10BASE T 100BASE TX Ports 10BASE T 1000BASE TX 1000BASE T Ports 10 100 1000 PoE Ports 100BASE X SFP Ports 1000BASE X SFP Ports Stacking...

Страница 13: ...ed on all copper ports Traffic Prioritization Supported IEEE Std 802 1D 1998 Edition Eight traffic queues per port Power over Ethernet Switch 5500 Supported on front panel ports except for the SFP por...

Страница 14: ...t PWR front view Unit LED Console Port Mode LED Power LED 10 100BASE TX Ports Port Status LEDs 1000BASE X Ports RPS LED Unit LED Console Port Mode LED RPS LED 10 100BASE TX Ports Port Status LEDs 1000...

Страница 15: ...o 10 100 1000BASE T Ports Two 1000BASE X Ports Unit LED RPS LED Power LED Mode LED Port Status LEDs 100BASE X Ports 10 100 1000BASE T Ports Console Port 3CR17251 91 SuperStack 4 Switch 5500G EI 24 Por...

Страница 16: ...partner 10 100 1000BASE T Ports Console Port SuperStack 4 Switch 5500G EI 48 port Port Status LEDs Unit LED 45 46 47 48 Dual Personality 10 100 1000BASE T 1000BASE X SFP Ports 1 4 3 2 5 6 7 8 9 10 11...

Страница 17: ...rts is auto negotiation enabled where the speed duplex and flow control modes are negotiated As the speed and duplex modes are fixed by the media type only the flow control is negotiated with the link...

Страница 18: ...nk is present blinking off for every packet received or transmitted Yellow A low speed 10 100 Mbps link is present blinking off for every packet received or transmitted Yellow flashing The port has fa...

Страница 19: ...No power is being delivered 1000BASE X SFP Port LEDs Speed Green A 1000 Mbps link is present Yellow flashing The port has failed post Off No link is present Duplex Green Full duplex packets are being...

Страница 20: ...le is attached Green flashing Switch is not compatible with the other Switches in the stack Yellow The XRN stack is functioning without the loop connection Off Stacking Cables are not connected Module...

Страница 21: ...Off The Switch is not receiving power or there is a fault with the Power Supply Unit LED Color Indicates Power Socket Redundant Power System Socket 100 240V 50 60Hz 2 5A Open Book Warning Labels NULL...

Страница 22: ...ort 10 Gbps XFP module 8 port 1000 Mbps SFP module This module shown in Figure 12 provides eight 1000 Mbps 1000Base X SFP transceiver ports Figure 12 8 port 1000 Mbps SFP module Notes The types of ava...

Страница 23: ...d above For the most up to date information refer to www 3com com For XFP transceiver specifications refer to 3Com s Web site at www 3Com com 1 port 10 Gbps XENPAK module This module shown in Figure 1...

Страница 24: ...tch automatically adjusts its power setting to any supply voltage in the range 100 240 VAC Open Book Warning Labels Before installing or removing any components from the Switch 5500 Family or carrying...

Страница 25: ...ch 5500 Baureihe installieren oder deinstallieren und bevor Sie Wartungsarbeiten ausf hren m ssen Sie die in Anhang A dieses Handbuchs aufgef hrten Sicherheitshinweise lesen ADVERTENCIA Antes de insta...

Страница 26: ...socket to connect the Switch to a 48 DC Redundant Power System Stacking Cable Ports Switch 5500G EI You can use these ports to connect the following cables Stacking Cable 3C17262 this cable enables yo...

Страница 27: ...ports belong to the untagged Default VLAN VLAN 1 with IEEE Std 802 1Q 1998 learning operational Management VLAN Fixed as VLAN 1 on 5500 SI units Can be any VLAN for 5500 EI 5500G EI units Link Aggrega...

Страница 28: ...28 CHAPTER 1 INTRODUCING THE SWITCH 5500 FAMILY...

Страница 29: ...A of this guide AVERTISSEMENT Consignes de s curit Avant d installer ou d enlever tout composant du Switch 5500 ou d entamer une proc dure de maintenance lisez les informations relatives la s curit qu...

Страница 30: ...element w z product lub przeprowadzeniem prac konserwacyjnych nale y zapozna si z informacjami o bezpiecze stwie zawartymi w Za czniku A niniejszego podr cznika Package Contents The Switch 5500 packa...

Страница 31: ...electrical noise such as radios transmitters and broadband amplifiers power lines and fluorescent lighting fixtures The switch is accessible and cables can be connected easily Water or moisture cannot...

Страница 32: ...separate from the AC supply used by units that generate high levels of AC noise air conditioning units for example No more than four switch units are placed on top of one another if the units are free...

Страница 33: ...2 and 3 for the other side of the switch 5 Insert the switch into the 19 inch rack and secure with suitable screws not provided Ensure that the ventilation holes are not obstructed 6 Connect the netw...

Страница 34: ...ing incorrect screws invalidates your warranty 5 Insert the switch into the 19 inch rack and secure with suitable screws not provided Ensure that the ventilation holes are not obstructed To rack mount...

Страница 35: ...e unit information label shows the switch s 3Com product name 3Com 3C number Unique MAC address Ethernet address Serial number You may need this information if you contact 3Com for Technical Support C...

Страница 36: ...et the isolation requirements in that specification WARNING Any RPS must be approved as a SELV output in accordance with IEC 60950 1 UL 60950 1 EN 60950 1 WARNING The characteristics of the Switch 550...

Страница 37: ...lled by the switch s internal power supply and not by the RPS Table 13 Switch Power Inputs Power Input before User Intervention Power Input after User Intervention Correct Response AC mains and RPS RP...

Страница 38: ...a rectifier does not affect the 48V DC output voltage Table 14 shows an example of the total power available from several 1500W rectifiers A minimum of two rectifiers are required for each shelf to p...

Страница 39: ...Breaker and Cable Ratings WARNING Make sure to follow the RPS Manufacturers recommendations when connecting the cable to the RPS WARNING Ensure that the circuit breaker in the RPS is in the open off p...

Страница 40: ...he AC mains and powers the switch if it is connected Connecting the Earthing Cable Use the earthing cable that accompanies your switch if the length is suitable Alternatively use the earthing cable sp...

Страница 41: ...ctionality of a standard Ethernet switch with a single power supply that can power multiple devices Using a PoE switch has the following advantages over an non powered network Reduced Cabling a PoE 80...

Страница 42: ...y that the Power Module is not installed upside down the module should be installed according to the letters If the module is installed upside down it will not be fully seated due the design of the ch...

Страница 43: ...e the switch units on top of each other ensuring that the feet of the upper unit sit fully on the lower unit The Power up Sequence The following sections describe how to prepare your Switch 5500 for o...

Страница 44: ...cross over MDIX cable The Auto MDIX feature only operates with auto negotiation enabled If auto negotiation is disabled all the switch ports are configured as MDIX cross over If you want to make a co...

Страница 45: ...ports Power over Ethernet on all front ports The Switch 5500 PWR supports Power over Ethernet on the 10 100 ports only Use these ports for Ethernet wiring within the same building only Choosing the Co...

Страница 46: ...meters in feet 1000BASE SX Multi mode 62 5 160 2m 220m 6 6 ft 721 8 ft Multi mode 62 5 200 2m 275m 6 6 ft 902 3 ft Multi mode 50 400 2m 500m 6 6 ft 1640 5 ft Multi mode 50 500 2m 550m 6 6 ft 1804 6 ft...

Страница 47: ...connect Gigabit Ethernet SFP ports on the switch directly to a multimode fiber optic cable 1000BASE LX SFP transceiver Use this transceiver to connect Gigabit Ethernet SFP ports on the switch directly...

Страница 48: ...ode fiber optic cable 100BASE BX10 D Use this transceiver to connect 100Mbps SFP ports on the switch directly to a single strand of a single mode fiber optic cable on the opposite end of a link that i...

Страница 49: ...position 2 Gently slide the transceiver into the SFP port until it clicks If the transceiver does not click into place remove it turn it over and re insert it 3 Remove the plastic protective cover if...

Страница 50: ...that is well grounded and remove the module from the package 2 Using a Phillips screwdriver remove the blank filler panel from the slot where you plan to install the module 3 Hold the module s front p...

Страница 51: ...nd module If 3Com receives the unit without the blanking plates in place your warranty could be invalidated WARNING Package the unit correctly to ensure that you do not invalidate the repair The Switc...

Страница 52: ...To package your Switch 5500 unit correctly orient the switch so that the front of the unit faces the front of the box rather than the right of the box as shown in Figure 20 Polystyrene Supports Switch...

Страница 53: ...ipping the Switch 5500 53 Figure 20 Correct Orientation When Packing the Switch 5500SI and 5500EI The Switch 5500 EI PWRs The 5500 EI PWRs should be orientated like the 5500G EI see Figure 19 and not...

Страница 54: ...54 CHAPTER 2 INSTALLING THE SWITCH...

Страница 55: ...he initial setup and the methods by which you can access the management software to manage the switch It includes the following topics Methods of Managing a Switch Setting Up Your Switch Manually Conf...

Страница 56: ...ver the Network For a description on how you can set up command line interface management using a local console port connection or over the network refer to Setting Up Command Line Interface Managemen...

Страница 57: ...tely over an IP network see Figure 23 Figure 23 Web Interface Management over the Network For more information about how to set up web interface management over the network refer to Setting Up Web Int...

Страница 58: ...r Up the Switch IP Information is automatically configured via DHCP See page 59 Do you want to manually configure the IP information Connect to the con sole port and use the Command Line Inter face Se...

Страница 59: ...oes not allow you to allocate static IP addresses Static IP addresses are necessary to ensure that the switch is always allocated the same IP information For most installations 3Com recommends that yo...

Страница 60: ...not allocated with an automatic IP address the IP configuration will be blank or shown as If you use the automatic IP configuration method you need to discover the automatically allocated IP informat...

Страница 61: ...onsole port this example describes a local connection to the console port rather than one using a modem You can do this while the switch is offline before you connect the switch to a network or while...

Страница 62: ...ch are 19 200 baud bits per second 8 data bits no parity 1 stop bit no hardware flow control Refer to the terminal emulation software s documentation for more information about these settings 3 Power...

Страница 63: ...xx xxx xxx xxx is the IP address and mmm mmm mmm mmm is the switch s subnet mask 6 Enter the quit command to exit System View and return to User View and then enter the switch s default gateway using...

Страница 64: ...switch make sure that you have A workstation running a suitable operating system Refer to Choosing a Browser on page 71 A Network Interface Card NIC A Category 5 twisted pair Ethernet cable with RJ 45...

Страница 65: ...the Address field If there is no response wait for one minute then re enter the IP address If your browser displays an option to install simplified Chinese characters click Cancel to continue do not...

Страница 66: ...00G EI or 5500 xx is displayed where xx is either SI or EI as shown in the example in Figure 29 Figure 29 User View Login using Telnet 4 Enter the system view command and press Enter 5 Enter interface...

Страница 67: ...utomatically allocated IP information 1 Connect your switch to the network 2 Power up the switch and wait for two minutes 3 Launch 3Com Network Director and run the Auto discovery wizard 3Com Network...

Страница 68: ...gin prompt does not begin immediately press Return a few times until it starts 3 At the username prompt type admin and press Return Press Return again at the password prompt If you have logged on corr...

Страница 69: ...n Connecting to the Console Port on page 61 You can now continue to manage and configure your switch using the CLI through its console port CLI Management over the Network To manage a switch using the...

Страница 70: ...g SSH 1 Ensure that you have set up the switch with IP information as described in Methods of Managing a Switch on page 56 2 Check that you have the IP protocol correctly installed on your management...

Страница 71: ...FTP server refer to the Configuration Guide Setting Up Web Interface Management This section describes how to set up Web interface management over the network Prerequisites Before setting up Web inter...

Страница 72: ...ur Web browser and enter the switch s IP address in the URL locator for example in the following format http xxx xxx xxx xxx 4 At the Username prompt enter admin as your user name and press Return At...

Страница 73: ...ult passwords you need to log in with a valid user name and password The switch has three default user names and each user name has a different password and access level These default users are listed...

Страница 74: ...e refer to the Configuration Guide Downloading the Configuration Conversion Utility The 3Com Switch 5500 Configuration Conversion Utility CCU enables you to convert the key configuration parameters fr...

Страница 75: ...23 lists the different variants of the Switch 5500 family how they physically interconnect and the level of XRN support offered by the Fabric It is not possible to create a Fabric by interconnecting a...

Страница 76: ...h 5500 EI 28 Port 3CR17161 91 Ports 27 up port and 28 down port using a 1000 Mbps SFP transceiver Full XRN functionality Switch 5500 EI 52 Port 3CR17162 91 Ports 51 up port and 52 down port using a 10...

Страница 77: ...your switch Stacking Switch 5500G EI Units 1 Ensure that the switch units that you wish to interconnect have the latest software agent installed You can use the display version command to check this 2...

Страница 78: ...he switch and locate the filename cfg file Do NOT under any circumstances remove the 3comoscfg def file this is the default configuration file For a detailed description of how XRN Technology operates...

Страница 79: ...en Traffic Yellow Link Fault Stacking Green OK Flashing Green Traffic Yellow Link Fault Yellow Flashing Stack Fault Yellow Flashing Stack Fault STK Caution This device has more than one power input Do...

Страница 80: ...80 CHAPTER 4 CREATING AN XRN STACKING FABRIC...

Страница 81: ...e The topics covered are Solving Problems Indicated by LEDs Solving Hardware Problems Solving Communication Problems Solving Fabric Formation Problems If you experience a problem that is not listed he...

Страница 82: ...blem The fault type will be indicated on the unit LEDs Contact your supplier for advice On powering up the PWR LED is flashing yellow A port has failed and has been automatically disabled You can veri...

Страница 83: ...could potentially reduce the lifetime of the switch The monitoring system polls the fan status at periodic intervals while the unit is powered up If one fan has failed in the switch a warning message...

Страница 84: ...meet those specified in Appendix C on page 127 4 Power cycle the unit If a further thermal shutdown occurs and all environmental conditions are satisfactory return the unit to 3Com Error message indi...

Страница 85: ...which the device resides The second part 8 in the example identifies the device within the network The natural subnet mask for this example is 255 255 255 0 If your network has a connection to the ex...

Страница 86: ...st priority port will lose power However if all the devices connected to the switch have equal priority levels then the port with the highest number will lose power By default the switch will allow a...

Страница 87: ...chapter describes how to upgrade software to your Switch 5500 It covers the following topics The Contents of the Executable File Upgrading from the Command Line Interface Upgrading from the Bootrom I...

Страница 88: ...elow Any attempt to upgrade the switch directly with xxxxxxxx exe and xxxxxxxxNetMan zip will fail The individual web btm or app files should be used to upgrade your switch as described below Upgradin...

Страница 89: ...r the remaining units in a fabric replace unit1 with unit2 on the next line and so on for each switch in the fabric 4 The unreserved option will cause the file to be deleted from both the flash and th...

Страница 90: ...guration file can be created by saving the configuration and renaming the xxx cfg file as 3ComOScfg def To back up the default configuration file on each switch in the fabric enter copy unit1 flash 3C...

Страница 91: ...e TFTP server s4a indicates the switch filename see Table 24 for further details Table 24 Switch 5500 Family Filenames 2 To download the Web user interface file enter tftp aaa aaa aaa aaa get s4h01_04...

Страница 92: ...mOScfg def unit2 flash Replace unit2 with unit3 and so on for each switch in the fabric 3 To copy the new Web user interface file to each switch in the fabric enter copy unit1 flash s4e01_04 web unit2...

Страница 93: ...your switch via FTP do the following 1 Enter the following command from User View ftp aaa aaa aaa aaa where aaa aaa aaa aaa is the IP address of the FTP server If the FTP server has been successfully...

Страница 94: ...wing information is displayed WARNING xmodem is a slow transfer protocol limited to the current speed settings of the auxiliary ports During the course of the download no exec input output will be ava...

Страница 95: ...ompt password 1 Select Enter the default is no password to display the following boot menu BOOT MENU 1 Download application file to flash 2 Select application file to boot 3 Display all files in flash...

Страница 96: ...1_04s56 app The s4b03_01_04s56 app file is the boot software The name of this file will vary depending on the switch type and the release version If the filename is in brackets for example test cfg th...

Страница 97: ...d file to flash Yes or No Y N 4 Enter y and the following information is displayed to indicate the file is downloading Attached TCP IP Interface to netdrv0 Attaching network interface lo0 done Loading...

Страница 98: ...ne 5 Repeat steps 1 to 4 for each of the remaining files XModem To upgrade software to your switch via XModem do the following 1 From the Boot Menu select option 1 Download application file to flash t...

Страница 99: ...1 to 5 for each of the remaining files Bootrom Upgrade This section describes how to indicate which file the switch is to boot from once the software has been loaded 1 From the Boot menu select optio...

Страница 100: ...choice 0 3 2 Select option 1 to display the following Load File name Switch IP address Server IP address 3 Enter the file name switch IP address and Server IP address to display the following Are you...

Страница 101: ...tion is displayed to indicate the file is downloading Attached TCP IP interface to netdrv0 Attaching network interface Io0 done Loading done Bootrom updating done Bootrom Upgrade via XModem To upgrade...

Страница 102: ...Press Enter to start the download The following information is displayed Now please start transfer file with XMODEM protocol If you want to exit Press Ctrl X Loading CCCCCCCCCCCCCCCCCCCCCCCCCCCCC 5 A...

Страница 103: ...hinweise enthalten Anweisungen die Sie zu Ihrer eigenen Sicherheit befolgen m ssen Alle Anweisungen sind sorgf ltig zu befolgen Sie m ssen die folgenden Sicherheitsinformationen sorgf ltig durchlesen...

Страница 104: ...nected to an earthed power supply to ensure compliance with safety standards WARNING Power Cord Set This must be approved for the country where it is used U S A and Canada The cord set must be UL appr...

Страница 105: ...to earth ground Imp dance la terre WARNING U K only If connecting a modem to the console port of the Switch 5500 only use a modem which is suitable for connection to the telecommunications system WAR...

Страница 106: ...to a reliable electrical earth or by connecting both It must be ensured that the earth connection is made before connecting the DC supply from the RPS WARNING Any RPS must be approved as an unearthed...

Страница 107: ...respecter une configuration qui permet un branchement sur une entr e d appareil EN60320 CEI 320 Etats Unis et Canada Le cordon doit avoir re u l homologation des UL et un certificat de la CSA Le cord...

Страница 108: ...ints d acc s RJ 45 Ceux ci sont prot g s par des prises de donn es Ils ne peuvent pas tre utilis s comme prises de t l phone conventionnelles standard ni pour la connection de l unit un r seau t l pho...

Страница 109: ...tion CC du RPS AVERTISSEMENT Le RPS doit tre approuv en tant que sortie SELV non reli e la terre conform ment la norme IEC 60950 1 UL 60950 1 EN 60950 1 AVERTISSEMENT Ces instructions doivent tre lues...

Страница 110: ...gebaut werden soll mu die Switch 5500 Einheit unter die schmaleren Hub Einheiten eingebaut werden VORSICHT Das Ger t mu geerdet sein VORSICHT Das Ger t mu an eine geerdete Steckdose angeschlossen werd...

Страница 111: ...t Sie sollten die den eingeschaltete n bertragungs Laser niemals durch eine Vergr erungseinrichtung betrachten Schauen Sie niemals direkt auf den Lichtwellen bertragungsanschluss und die Kabelenden de...

Страница 112: ...lung Aus befindet VORSICHT Stellen Sie auf jeden Fall sicher dass die positive Klemme am switch an die positive gemeinsame Klemme der RPS und die negative Klemme am switch an die negative gemeinsame K...

Страница 113: ...or aislador con relaci n 1 1 con el punto de conexi n EE UU y Canad El conjunto de cables debe estar homologado por UL y tener la certificaci n CSA La especificaci n m nima del cable flexible es N 18...

Страница 114: ...tos conectores de datos ADVERTENCIA Puertos de fibra ptica seguridad ptica Nunca mire el l ser de transmisi n a trav s de una lente de aumento mientras est encendido No mire nunca directamente al puer...

Страница 115: ...n de abierto desactivado al conectar el cable al RPS ADVERTENCIA deber asegurarse de que el terminal positivo del switch est conectado al terminal positivo com n del RPS y de que el terminal negativo...

Страница 116: ...di collegamento secondario Stati Uniti e Canada Il cavo deve avere l approvazione UL e la certificazione CSA La specifica minima per il cavo flessibile N 18 AWG Tipo SV o SJ 3 conduttori Il set di ca...

Страница 117: ...r di trasmissione attraverso uno strumento ottico di ingrandimento quando acceso Non guardare direttamente la porta TX a fibre ottiche e le estremit del cavo a fibre ottiche quando sono accese AVVERTE...

Страница 118: ...rificare che il polo positivo sullo switch sia collegato al polo positivo comune dell RPS e che il polo negativo sullo switch sia collegto al polo negativo salvavita dell RPS AVVERTENZA prima di colle...

Страница 119: ...ador aislador con relaci n 1 1 con el pun to de conexi n secundario etiquetado como neutro conectado directa Stany Zjednoczone i Kanada Zestaw przewod w musi posiada zezwolenie UL oraz certyfikat CSA...

Страница 120: ...czon diod laser transmisyjny przez urz dzenie wzmacniaj ce Nie wolno nigdy patrze bezpo rednio na port w kna TX i ko c wki wiat owod w je li s zasilane OSTRZE ENIE To urz dzenie ma kilka punkt w pod...

Страница 121: ...ka Switch 5500 opisan w Dodatku C Specyfikacja techniczna OSTRZE ENIE Podczas pod czania kabla do zasilacza RPS nale y przestrzega zalece producenta OSTRZE ENIE Podczas pod czania kabla do zasilacza R...

Страница 122: ...122 APPENDIX A SAFETY INFORMATION...

Страница 123: ...PC Terminal Cable connector 25 pin male female only required if screen always required required for handshake Screen DTR TxD RxD CTS Ground DSR RTS DCD Screen DCD RxD TxD DTR Ground DSR RTS CTS Shell...

Страница 124: ...7 8 6 5 1 4 1 2 3 4 5 6 7 8 20 Switch 5500 Cable connector RJ 45 female RS 232 Modem Port Cable connector 25 pin male Pin Number 10 100 1000 Ports configured as MDI 1 Transmit Data Bidirectional Data...

Страница 125: ...red as MDIX 1 Receive Data Bidirectional Data B 2 Receive Data Bidirectional Data B 3 Transmit Data Bidirectional Data A 4 Not assigned Bidirectional Data A 5 Not assigned Bidirectional Data D 6 Trans...

Страница 126: ...126 APPENDIX B PIN OUTS...

Страница 127: ...for the following Switch 5500 28 Port Switch 5500 PWR 28 Port Switch 5500 52 Port Switch 5500 PWR 52 Port Switch 5500 FX 28 Port Switch 5500G EI 24 Port Switch 5500G EI PWR 24 Port Switch 5500G EI 48...

Страница 128: ...ng paras 2 1 2 2 2 30 and 2 32 Operational testing paras 2 1 2 2 2 30 and 2 13 Safety Agency Certifications UL 60950 EN60950 CSA 22 2 No 60950 IEC 60950 EMC Emissions CISPRR 22 Class A EN55022 Class A...

Страница 129: ...ety Agency Certifications UL60950 EN60950 CSA 22 2 No 60950 IEC 60950 EMC Emissions CISPR 22 Class A EN55022 Class A FCC Part 15 Subpart B Class A ICES 003 Class A VCCI Class A EN61000 3 2 EN61000 3 3...

Страница 130: ...ras 2 1 2 2 2 30 and 2 32 Operational testing paras 2 1 2 2 2 30 and 2 13 Safety Agency Certifications UL60950 EN60950 CSA 22 2 No 60950 IEC 60950 EMC Emissions CISPR 22 Class A EN55022 Class A FCC Pa...

Страница 131: ...y Agency Certifications UL60950 EN60950 CSA 22 2 No 60950 IEC 60950 EMC Emissions CISPR 22 Class A EN55022 Class A FCC Part 15 Subpart B Class A ICES 003 Class A VCCI Class A EN61000 3 2 EN61000 3 3 I...

Страница 132: ...g paras 2 1 2 2 2 30 and 2 32 Operational testing paras 2 1 2 2 2 30 and 2 13 Safety Agency Certifications UL 60950 EN60950 CSA 22 2 No 60950 IEC 60950 EMC Emissions CISPRR 22 Class A EN55022 Class A...

Страница 133: ...testing paras 2 1 2 2 2 30 and 2 32 Operational testing paras 2 1 2 2 2 30 and 2 13 Safety Agency Certifications UL 60950 EN60950 CSA 22 2 No 60950 IEC 60950 EMC Emissions CISPRR 22 Class A EN55022 Cl...

Страница 134: ...2 2 30 and 2 13 Safety Agency Certifications UL 60950 EN60950 CSA 22 2 No 60950 IEC 60950 EMC Emissions CISPRR 22 Class A EN55022 Class A FCC Part 15 Subpart B Class A ICES 003 Class A EN61000 3 2 EN6...

Страница 135: ...and 2 32 Operational testing paras 2 1 2 2 2 30 and 2 13 Safety Agency Certifications UL 60950 EN60950 CSA 22 2 No 60950 IEC 60950 IEC825 1 EN60825 1 EMC Emissions CISPRR 22 Class A EN55022 Class A FC...

Страница 136: ...cy Certifications UL 60950 EN60950 CSA 22 2 No 60950 IEC 60950 IEC825 1 EN60825 1 EMC Emissions CISPRR 22 Class A EN55022 Class A FCC Part 15 Subpart B Class A ICES 003 Class A VCCI Class A AS NZS 354...

Страница 137: ...age testing paras 2 1 2 2 2 30 and 2 32 Operational testing paras 2 1 2 2 2 30 and 2 13 Safety Agency Certifications UL 60950 EN60950 CSA 22 2 No 60950 IEC 60950 EMC Emissions CISPRR 22 Class A EN5502...

Страница 138: ...on UDP RFC 768 IP RFC 791 ICMP RFC 792 TCP RFC 793 ARP RFC 826 TFTP RFC 783 DHCP RFC 2131 RFC 2132 RFC 1534 BOOTP RFC 951 RFC 1497 Network Login IEEE 803 1x RADIUS RFC 2618 2620 Link aggregation IEEE...

Страница 139: ...irements The Earthing Lead shall comply with the following safety standards UL Subject 758 UL 1581 and CSA C22 2 No 210 UL VW 1 and CSA FT1 Vertical Flame Test Voltage Rating 600V AWG 12 Insulation Th...

Страница 140: ...140 APPENDIX C TECHNICAL SPECIFICATIONS...

Страница 141: ...Request If you have trouble registering your product please contact 3Com Global Services for assistance Purchase Value Added Services To enhance response times or extend warranty benefits contact 3Co...

Страница 142: ...uct Support heading at http www 3com com Software Upgrades are the software releases that follow the software version included with your original product In order to access upgrades and related docume...

Страница 143: ...directory of contact information posted on the 3Com web site at http csoweb4 3com com contactus Country Telephone Number Country Telephone Number Asia Pacific Rim Telephone Technical Support and Repai...

Страница 144: ...2 1 800 998 2112 52 5 201 0010 1 800 998 2112 1 800 998 2112 0800 13 3COM 1 800 998 2112 AT T 800 998 2112 AT T 800 998 2112 AT T 800 998 2112 1 800 998 2112 AT T 800 998 2112 AT T 800 998 2112 Guatem...

Страница 145: ...om Network Supervisor 3Com Network Supervisor 3NS is an easy to use management application that graphically discovers maps and monitors the network and links It maps devices and connections so you can...

Страница 146: ...Network Director can help you manage your 3Com network and to download a trial version go to www 3com com 3nd 3Com Network Access Manager 3Com Network Access Manager is installed seamlessly into Micr...

Страница 147: ...ly managed These include SNMP capable devices such as switches routers security switches the 3Com VCX IP Telephony server and wireless access points Up to 250 devices Up to 1 000 devices Up to 5 000 d...

Страница 148: ...148 APPENDIX E 3COM NETWORK MANAGEMENT...

Страница 149: ...ites 32 IP addressing registered 85 IP configuration 59 L LEDs 18 logging in as a default user 73 M management methods 56 preparing for 60 setting up 55 manual setup console port 61 front panel port 6...

Страница 150: ...nstallation 29 32 power socket 24 powering up 43 rack mounting 32 size 127 weight 127 XRN Distributed Fabric 75 76 system specifications 127 T troubleshooting 81 87 U upgrading software bootrom 95 boo...

Страница 151: ...er Move the equipment away from the receiver Plug the equipment into a different outlet so that equipment and receiver are on different branch circuits If necessary the user should consult the dealer...

Отзывы: