![3Com 3CR17251-91 - Switch 5500G-EI Stackable Gigabit... Скачать руководство пользователя страница 99](http://html2.mh-extra.com/html/3com/3cr17251-91-switch-5500g-ei-stackable-gigabit/3cr17251-91-switch-5500g-ei-stackable-gigabit_getting-started-manual_3382612099.webp)
Bootrom Upgrade
99
Load File name:
Switch IP address:
Server IP address:
FTP User Name:
FTP User Password:
3
Enter the file name, Switch IP address, Server IP address, FTP user name
and password to display the following:
Are you sure to update your bootrom? Yes or No(Y/N)
4
Enter
y
and the following information is displayed to indicate the file is
downloading:
Attached TCP/IP interface to netdrv0
Attaching network interface Io0...done
Loading.................................
...............done
Bootrom updating............done!
Bootrom Upgrade via
XModem
To upgrade the bootrom firmware from the Boot menu via XModem do
the following:
1
From the Boot Menu, select option 6 to display the following:
1. Set TFTP protocol parameter
2. Set FTP protocol parameter
3. Set XMODEM protocol parameter
0. Return to boot menu
Enter your choice(0-3):
2
Select option 3 to display the following:
Please select your download baudrate:
1. 9600
2.*19200
3. 38400
4. 57600
5. 115200
0. Return
Enter your choice(0-5):
3
Select option 2 to set the baudrate to 19200.
You will also need to change the baudrate on Hyperterminal to 19200
bps and select XModem protocol.
Содержание 3CR17251-91 - Switch 5500G-EI Stackable Gigabit...
Страница 8: ......
Страница 48: ...48 CHAPTER 2 INSTALLING THE SWITCH...
Страница 70: ...70 CHAPTER 3 SETTING UP FOR MANAGEMENT...
Страница 76: ...76 CHAPTER 4 CREATING AN XRN STACKING FABRIC...
Страница 84: ...84 CHAPTER 5 PROBLEM SOLVING...
Страница 122: ...122 APPENDIX A SAFETY INFORMATION...
Страница 126: ...126 APPENDIX B PIN OUTS...
Страница 140: ...140 APPENDIX C TECHNICAL SPECIFICATIONS...
Страница 148: ......