
198
C
HAPTER
16: M
ANAGING
S
YSTEM
L
OGS
The
Logging Setup Page
contains the following fields:
■
Enable Local Logging
— Specifies if device local logs for Cache and
servers are enabled. Console logs are enabled by default.
■
Severity level — Specifies the minimum severity level for which a
message will be logged. When a severity level is selected, all severity
level choices above the selection are selected automatically. The
possible field values are:
■
Emergency
— The highest warning level. If the device is down or
not functioning properly, an emergency log message is saved to
the specified logging location.
■
Alert
— The second highest warning level. An alert log is saved, if
there is a serious device malfunction; for example, all device
features are down.
■
Critical
— The third highest warning level. A critical log is saved if a
critical device malfunction occurs; for example, two device ports
are not functioning, while the rest of the device ports remain
functional.
■
Error
— A device error has occurred, for example, if a single port is
offline.
■
Warning
— The lowest level of a device warning. The device is
functioning, but an operational problem has occurred.
■
Notice
— Provides device information.
■
Info
— Provides device information.
■
Debug
— Provides debugging messages.
■
Not Active
— Provides no messages.