Important Safety Information

 

WARNING:

 Installation and removal of the 

Module must be carried out by qualified 
personnel only. Before installing the Module 
into a hub, you must first disconnect the hub 
from the mains power supply. For full safety 
instructions, refer to the user guide that 
accompanies the hub.

L’information de Sécurité Importante

 

AVERTISSEMENT: 

L'installation et l'enlèvement 

de l'unité doivent être faits seulement par le 
personnel qualifié. Avant d'installer le module 
dans une unité ou de l'en retirer, vous devez 
d'abord déconnecter les alimentations 
électriques de l'unité. Pour plus de details sur 
les instructions de sécurité, veuillez vous reférer 
au guide utilisateur qui accompagne cette 
unité.

Wichtige Sicherheitsinformationen

 

WARNUNG: 

Ein- und Ausbau des Gerätes ist 

nur von Fachpersonal vorzunehmen. Vor der 
Installation des Module in das Gerät muß das 
Gerät vom Netz getrennt werden. Bitte 
beachten Sie die Sicherheitsinformationen im 
Handbuch des Gerät.

Installing the Module into a Hub

 

CAUTION: 

Do not install the Module in 

unsuitable hubs such as those in the Hub 10, 
PS Hub, and Hub 100 ranges. Contact your 
supplier for advice if necessary. 

 

1

Ensure that the hub is disconnected from the 
mains power supply, and you are wearing an 
anti-static wristband connected to a suitable 
earth point.

 

2

Place the hub on a flat surface. Using a 
suitable screwdriver, remove one blanking 
plate from the rear of the hub to reveal a 
slot for the Module. Do not remove any 
other screws from the rear of the hub. 

 

3

Keep the blanking plate in a safe place. 
If you remove the Module, you must replace 
the blanking plate to prevent dust and 
debris entering the hub and maintain 
cooling air circulation.

 

4

Hold the Module so that the text on the 
front panel is upright, and slide it into the 
hub, ensuring the edge connector is fully 
engaged. The front panel of the Module 
should lie flush against the rear panel of the 
hub. Fix the front panel of the Module to 
the hub using the two screws from the 
blanking plate.

 

5

Power up the hub.

 

6

Check the LEDs on the hub to ensure that 
the Module is operating correctly.

Setting the MDI/MDIX Switch

The Module has a slide switch on the front 
panel for configuring the port as MDI or 
MDIX. The Module is supplied with the switch 
set to MDI.

The general rule for setting the switch is:

LEFT — Set to MDIX (cross-over) — for 
connecting the Module port to an endstation 
or server, using a ‘straight through’ cable.

RIGHT (factory setting) — Set to MDI — for 
connecting the Module port to an MDIX port 
on another hub or switch, using a ‘straight 
through’ cable.

Connecting the Module

 

1

Insert the RJ45 connector on your cable 
into the socket on the Module. Connect the 
other end of the cable to an appropriate 
device with a 100Mbps Fast Ethernet 
100BASE-TX twisted pair interface. The 
100BASE-TX port supports Category 5 cable 
over a maximum length of 100m (328ft).

LEDs

LEDs on the front of the hub indicate the 
Module status. Refer to the user guide that 
accompanies the Dual Speed Hub 500 unit for 
a description of the LED behavior.

Using the Distance Extender

The Distance Extender will connect to any Fast 
Ethernet device with a twisted pair port. Links 
of Category 5 cable may be a maximum 
length of 100m. 

You can connect two or more Dual Speed Hub 
500 units using a Distance Extender at one 
end of the link to form chains of units or 
stacks. Figure 2 shows the process of chain 
building.

You may install Distance Extender Modules in 
any combination of transceiver slots within a 
Dual Speed Hub 500 stack. 

Take care not to create loops in the network.

For distances greater than 100m, use the 
100BASE-FX Distance Extender.

Problem Solving

If you suspect a problem, carry out the 
following checks before contacting your 
supplier:

Ensure the unit in which the Module is fitted 
is powered up.

Ensure the Module is correctly installed.

Ensure that the device at the far end of the 
segment is powered up and operating 
correctly.

Ensure you are using the correct cable.

Ensure that the cable and connectors are free 
from damage and that the RJ45 connector at 
each end of the cable is correctly engaged in 
its appropriate socket.

Check that the MDI/MDIX setting is correct 
for your configuration. See “Setting the 
MDI/MDIX Switch”,
 above.

 

Figure 1   

100BASE-TX Distance Extender Module

 

Figure 2   

Chaining Dual Speed Hub 500 stacks with 100BASE-TX Distance Extender Modules

Connections from Distance Extender to
Dual Speed Hub 500 TP port (or any other
Fast Ethernet TP device)