background image

Copyright © 2006, 3Com Corporation. All rights reserved. No part of this documentation may be reproduced in any form or 

by any means or used to make any derivative work (such as translation, transformation, or adaptation) without written 

permission from 3Com Corporation.

 

3Com Corporation reserves the right to revise this documentation and to make changes in content from time to time without 

obligation on the part of 3Com Corporation to provide notification of such revision or change.

 

3Com Corporation provides this documentation without warranty, term, or condition of any kind, either implied or expressed, 

including, but not limited to, the implied warranties, terms or conditions of merchantability, satisfactory quality, and fitness for 

a particular purpose. 3Com may make improvements or changes in the product(s) and/or the program(s) described in this 

documentation at any time. 

If there is any software on removable media described in this documentation, it is furnished under a license agreement 

included with the product as a separate document, in the hard copy documentation, or on the removable media in a directory 

file named LICENSE.TXT or !LICENSE.TXT. If you are unable to locate a copy, please contact 3Com and a copy will be provided 

to you. 

UNITED STATES GOVERNMENT LEGEND

 

If you are a United States government agency, then this documentation and the software described herein are provided to you 

subject to the following: 

 

All technical data and computer software are commercial in nature and developed solely at private expense. Software is 

delivered as “Commercial Computer Software” as defined in DFARS 252.227-7014 (June 1995) or as a “commercial item” as 

defined in FAR 2.101(a) and as such is provided with only such rights as are provided in 3Com’s standard commercial license 

for the Software. Technical data is provided with limited rights only as provided in DFAR 252.227-7015 (Nov 1995) or FAR 

52.227-14 (June 1987), whichever is applicable. You agree not to remove or deface any portion of any legend provided on any 

licensed program or documentation contained in, or delivered to you in conjunction with, this User Guide.

 

Unless otherwise indicated, 3Com registered trademarks are registered in the United States and may or may not be registered 

in other countries.

 

3Com, the 3Com logo, are registered trademarks of 3Com Corporation. 

 

Intel and Pentium are registered trademarks of Intel Corporation. Microsoft, MS-DOS, Windows, and Windows NT are 

registered trademarks of Microsoft Corporation. 

UNIX is a registered trademark in the United States and other countries, licensed 

exclusively through X/Open Company, Ltd. 

All other company and product names may be trademarks of the respective companies with which they are associated. 

3Com Corporation 

350 Campus Drive 

Marlborough, MA 

01752-3064 

 

Содержание 3C13636

Страница 1: ...3Com Router 3000 Ethernet Family Installation Guide 3C13636 www 3Com com Part Number 10014941 Rev AA February 2006...

Страница 2: ...ted States government agency then this documentation and the software described herein are provided to you subject to the following All technical data and computer software are commercial in nature an...

Страница 3: ...input power cord 2 3 2 5 Connecting the Router to a Console Terminal 2 4 2 5 1 Console cable 2 4 2 5 2 Connecting the console cable 2 4 2 6 Connecting the Router to LAN 2 5 2 6 1 Ethernet cable 2 5 2...

Страница 4: ...3Com Router 3000 Ethernet Family Installation Guide Table of Contents ii...

Страница 5: ...namic VPN DVPN They can provide tunnel connections to remote users to build VPNs that can be internets intranets or access networks The series support firewall AAA authentication authorization account...

Страница 6: ...2 3 Ethernet LED LAN1 4 Ethernet LED LAN0 5 WAN LED 6 SYSTEM LED SYS 7 POWER LED PWR Figure 1 1 Front view of the 3Com Router 3000 Ethernet 1 Power switch 2 Power socket 3 Console port CONSOLE 4 Ether...

Страница 7: ...mm 11 81 x 7 09 x 1 77 in the maximum measurements including the bulge Weight 1kg 2 20 lb Operating temperature 0 to 40 C 32 to 104 F Relative humidity non condensing 10 to 90 1 2 3 LEDs You can gathe...

Страница 8: ...standard Asynchronous RS232 Baud rate 9600 default to 115200 bps Service Connection to an ASCII terminal Connection to the serial interface on a PC to run the terminal emulation program on the PC Comm...

Страница 9: ...uring installation making sure that it has good skin contact z Reserve adequate clearance at the air intake and exhaust vents for ventilation z For power supply use a single phase three line power soc...

Страница 10: ...the four brackets at the bottom of the router Caution z Securely anchor these four mounting screws in the vertical surface If the screws are not properly anchored strain of the network cable connectio...

Страница 11: ...The Router 3036 external AC input power supply is provided with these specifications z Input rated voltage 100 to 240 V a c 50 to 60 Hz z Max input tolerance 90 to 264 V a c 50 to 60 Hz z Input curren...

Страница 12: ...5 2 Connecting the console cable Follow these steps to connect the router to a console terminal Step 1 Select a console terminal The console terminal can be either a standard ASCII terminal with an R...

Страница 13: ...cable at both ends of which the wires are crimped in the RJ 45 connectors in different sequence The cable is used for connecting the same type of devices such as PC to PC or PC to router Caution In pr...

Страница 14: ...Installing the Router 2 6 2 7 Verifying Installation After you complete installation verify that z The proper power supply is used z The grounding wire of the router is correctly connected z The cons...

Страница 15: ...ort on the router and the DB9 connector to the serial port on the console terminal a PC for example as shown in Figure 3 1 PC Router Console cable Console port Figure 3 1 Local configuration through t...

Страница 16: ...3 3 displays Step 3 Select the serial port to be used from the Connect Using dropdown menu The serial port must be the same port connected by the console cable Figure 3 3 Setting the connection port S...

Страница 17: ...g communications parameters Step 6 Click OK The HyperTerminal dialogue box appears Step 7 Select Properties Step 8 In the Properties dialog box select the Settings tab as shown in Figure 3 5 Step 9 Se...

Страница 18: ...1500000 3Com 3000 Routers Boot ROM V9 00 Copyright C 1997 2003 by 3Com Corp CO LTD Compiled at 17 11 06 Aug 19 2003 Testing memory OK 64M bytes SDRAM 8192k bytes flash memory Hardware Version is MTR 2...

Страница 19: ...ot the router Type the correct password and press Enter If no Boot ROM password is configured just press Enter The system accesses the following Boot menu Boot Menu 1 Download application program with...

Страница 20: ...arget name tn startup script s other o Note You can change the parameter settings behind the colons The 3036 allows you to download programs through both TFTP and FTP z After you set the parameters se...

Страница 21: ...option 8 to ignore the version check during software upgrading Note that this option works only once after you select it Then the system resumes version check at reboot 3 2 2 Upgrading Programs throu...

Страница 22: ...k Send Step 6 After completing downloading the system begins writing data to the Flash and then displays the following information in the terminal interface indicating completion of the downloading Do...

Страница 23: ...tion of the Boot ROM program so you can make a second attempt once errors occur 3 2 3 Backing up and Restoring the Extended Segment of the Boot ROM Program 3 2 3 1 Backing up the extended segment of t...

Страница 24: ...You need to purchase and install one by yourself Follow these steps to upgrade an application program through TFTP or FTP 1 Start the TFTP or FTP server Start the TFTP or FTP server on the PC connect...

Страница 25: ...e following message appears boot device fei unit number 0 processor number 0 host name 8040 file name Q8040 BIN inet on ethernet e 10 110 27 235 host inet h 10 110 27 231 user u 8040 ftp password pw 8...

Страница 26: ...d If POWER LED is still OFF after you check against the items listed above contact your agent 4 2 Troubleshooting the Configuration System If the router is operating normally after it is powered on it...

Страница 27: ...powered on Solution Make sure you have set on your terminal HyperTerminal Baud rate 9600 Databit 8 Parity check none Stopbit 1 Flow control none Terminal emulation VT100 Reconfigure the parameters if...