3B SCIENTIFIC® PHYSICS

 

 

 
 
 
 

3B Netlog™ with Ethernet port  

1000541 (115 V, 50/60 Hz) 
1000009 (230 V, 50/60 Hz)

 

 

Instruction manual  

14/06 MEC 

 

 
 
 

1. Safety instructions  

To guarantee the safe functioning of the 
3B NET

log

™ equipment, it is necessary to 

abide by the following instructions:  

 

Do not connect the 3B NET

log

™ device to 

a voltage in excess of ±20V or current in 
excess of ±2A.  

 

Make sure the 3B NET

log

™ device does 

not come into contact with water.  

 

The 3B NET

log

™ device should not be 

exposed to temperatures above 80°C. 

The operating voltage input is protected 
against polarity reversal. However, it is not 
protected against excess voltage.  

 

Do not apply voltage in excess of 4.5V to 
the operating voltage input.  

Use of the Ethernet port requires a power sup-
ply of higher power rating. 

 

When using the 3B NET

log

™ unit with the 

Ethernet port, supply power by means of a 
plug-in power supply. 

 
 

2. Scope of delivery  

1 3B 

NET

log

™ device 

Power supply unit (4.5V DC, 300mA)  

USB cable  

1 Installation 

CD 

 

 
 

Содержание 3B Netlog 1000009

Страница 1: ...og device does not come into contact with water The 3B NETlog device should not be exposed to temperatures above 80 C The operating voltage input is protected against polarity reversal However it is not protected against excess voltage Do not apply voltage in excess of 4 5V to the operating voltage input Use of the Ethernet port requires a power sup ply of higher power rating When using the 3B NET...

Страница 2: ...4 1 Analogue inputs Voltage inputs channels A and B Measuring equipment 2 Differential amplifi ers Measuring range 200mV 2V 20V Surge voltage protection Max 40V Connections 4 mm safety sockets Current input channel A Measuring range 200mA 2A Excess current protection Max 2 5A Connections 4 mm safety sockets Sensor inputs channels A and B Sensor type Analogue Sensor identification Automatic Sensor ...

Страница 3: ...y lighting on and off briefly press the button Date Time button Switching on the battery and temperature displays Switching on the time display Switching on the date display Selection of operating mode manual or automatic Confirming the display Store button Communication to data logger Scrolling down the menu Selecting Yes or No Confirming the display Rate button Selection of sampling rate Scrolli...

Страница 4: ...ia a computer never press the buttons on the 3B NETlogTM console 7 1 Driver installation Before installing the 3B NETlab software it is important to install the USB driver Insert the installation CD into the CD ROM drive of the computer Connect 3B NETlog to the computer via the USB cable The computer reports that it has detected a new hardware Windows XP Do not activate Windows Update Select Insta...

Страница 5: ...er Click Yes to confirm that the file should be overwritten 7 2 Software installation Note on installing the software For this software please refer to the installa tion instructions available in the 3B NETlab software manual 8 Operating without a computer Operating a 3B NETlog device without a computer is achieved by using the buttons on the operating panel The functions of these buttons may chan...

Страница 6: ...NETlog equipment is ready to conduct measurements 8 6 Setting the sampling rate Press the Rate button the options list for SAMPLE RATE will appear Select the desired sampling rate with the Rate or Store button Press the Date Time button the settings STORE ANALOGUE INPUT 1 STORE ANALOGUE INPUT 2 and STORE BI NARY INPUTS will appear in succession Select YES or NO for each setting with the Rate or St...

Страница 7: ... button until the display shows the following Use the Date Time button to confirm this then plug in the Ethernet cable to connect the 3B NETlog unit to the local network Now you can modify the known fixed IP address by pressing the Store or Rate buttons along with Channel or Date Time e g Confirm the address by pressing the Date Time button Now enter or modify the subnet mask e g Confirm the mask ...

Страница 8: ...since the beginning of the read opera tion Time remaining shows the approximate time remaining for the read operation Options the following settings can be made here Decimal separator sets the decimal separa tor which is used in exported files Date Time format specifies the time and date format which is used in exported measurement files List left shows the acquired data List right additional sele...

Страница 9: ...to search and install older firmware versions 12 Format of exported files Exported files have the following format the words shown here between the delimiters are simply placeholders for actual data Entries are separated by tab characters Depending on the settings some columns may be omitted Date Time Inputs Measurement modes Sampling rate Number of measurement re cords Index tab Absolute date tim...

Страница 10: ...oype tested EN 61326 1 Tested for noise immunity and interference Conformity with EU guidelines is indicated by the CE marking on the device 16 Licence 3B Netlog and 3B Netlab are registered trademarks of 3B Scientific GmbH in Germany and other countries The 3B Netlab computer program is pro tected by worldwide copyright It may be used exclusively for educational purposes in schools and educationa...

Страница 11: ...3B Scientific GmbH Rudorffweg 8 21031 Hamburg Germany www 3bscientific com Subject to technical modifications Copyright 2014 3B Scientific GmbH ...

Страница 12: ......

Отзывы: