Predator Hybrid Installation Manual V2.1.25
Page 8
© 360 Vision Technology Ltd.
5 Connections to Predators with HMA
When the HMA (Hinged Mount Adaptor) is fitted to the Predator Hybrid, the ‘Predator Composite Cable’ is not
used. Connections between the power supply and Predator use conventional cables as detailed below.
30Vdc Power connections between Predator PSU and Predator that is fitted with HMA
Cable Size
No IR
SIR110
SIR140WL
0.75mm²
85m
32m
32m
1.00mm²
113m
43m
43m
1.25mm²
141m
54m
54m
1.50mm²
170m
65m
65m
2.50mm²
283m
108m
108m
3.00mm²
340m
130m
130m
4.00mm²
450m
173m
173m
Camera current draw table.
No Lamps
IR80/
SIR110
IR110WL/
SIR140WL
Power Up
1.2A
1.2A
1.2A
Idle
(No Lamps)
0.83A
0.83A
0.83A
PTZ/Wiper
(No Lamps)
1.45A
1.45A
1.45A
Idle
(IR Lamps)
N/A
2.3A
2.3A
PTZ/Wiper
(IR Lamps)
N/A
3.1A
3.1A
Idle
(White Lamps)
N/A
N/A
2A
PTZ/Wiper
(White Lamps)
N/A
N/A
2.7A
Voltage at PSU
30Vdc
30Vdc
30Vdc
Voltage at Camera
(PTZ/IR Fast tour)
28.5Vdc
(No Lamps)
27Vdc
27Vdc
Current/Voltage test at
cable length (1.5mm²)
40m
40m
40m
Ethernet connections between Predator PSU and Predator that is fitted with HMA.
The Ethernet connection uses standard CAT5, CAT5e or CAT6 cables fitted with RJ45 connectors.
RJ45
CAT5, CAT5e, CAT6 Cable
Signal
Pin 1
White with Orange Band
Tx+
Pin 2
Orange
Tx-
Pin 3
White with Green Band
Rx+
Pin 4
Blue
Pin 5
White with Blue Band
Pin 6
Green
Rx-
Pin 7
White with Brown Band
Pin 8
Brown