6
2VV.
Creating innovative solutions for you and your business since 1995.
ver.2 10-01-20
5. TECHNICAL PARAMETERS
Air curtains with a water coil for a water temperature gradient of 70º/50° C and at an intake air
temperature of +18° C
Type
Air flow
[m3/h]
Heat output
[kW]
Outlet
temperature [°C]
Water flow
[l/s]
Pressure loss
[kPa]
VCFI4B-B100-V-...EC
1700
12,57
41,6
0.15
3,73
VCFI4B-B150-V-...EC
2550
19,95
43,2
0.24
10,79
VCFI4B-B200-V-...EC
3400
26,42
43
0.32
9,32
VCFI4B-B250-V-...EC
4250
32,26
42,3
0.39
9,61
Air curtains with a water coil for a water temperature gradient of 60º/40° C and at an intake air
temperature of +18° C
Type
Air flow
[m3/h]
Heat output
[kW]
Outlet
temperature [°C]
Water flow
[l/s]
Pressure loss
[kPa]
VCFI4B-B100-V-...EC
1700
9,07
34,7
0.11
2,06
VCFI4B-B150-V-...EC
2550
14,76
36,2
0.18
6,38
VCFI4B-B200-V-...EC
3400
19,46
36
0.24
5,4
VCFI4B-B250-V-...EC
4250
23,6
35,4
0.29
5,49