background image

 

Basic 2N

®

SmartCOM Setup 

  Insert the SIM card that supports data. Connect 

the antenna and then the power supply. 

  2N

®

 SmartCOM  will  start  with  the  default 

parameters. 

Use 

the 

2N

® 

SmartCOM 

Terminal  Config  program  for  basic  settings. 
Install the program from the included CD and 
get connected via the serial port. 

  Upon power up, the port is in the data mode 

and  retransmits  everything  from  the  GSM 
input. 

The 

Terminal 

Config 

program 

automatically  switches  the  port  into  the 
command mode.  

  Set  the  basic  communication  parameters  in 

the  Terminal  Config  program  for  your  PC 
serial  port.  The  2N

®

 SmartCOM  default 

parameters for the serial port are as follows: 

o

 

Baudrate:  115,200 Bdps 

o

 

Data bits:  8 

o

 

Stop bits:  1 

o

 

Parity:      None 

o

 

Flow ctrl.: None 

 

No  configuration  access  password  is 

required by default. 

  Set all parameters comfortably using forms in 

the  Terminal  Config  program:  GPRS  APN, 
PIN,  2N

®

 SmartCOM  Server  address  and 

port settings. 

  Also,  set  other  communication  parameters 

for  the  ports  using  the  program  tags  or  use 
all  AT  commands  supported  by  the  device 
using the Own (User-defined) AT commands 
tag. Refer to the CD User Manual for the list 
of commands supported.  

  You can also set one of two (three in fact but 

the  UDP  Client  mode  is  unavailable  now) 
modes for 2N

®

 SmartCOM to work in. 

TCP Client  Mode 

  The  server  receives  registrations  from 

terminals providing central administration. 

  Refer  to  the  2N

® 

SmartCOM  User  Manual  for 

details on the server settings, management and 
use. 

  Make  sure  that  the  2N

® 

SmartCOM  Server 

address, 

listening 

port 

and 

terminal 

authentication  password      have  been  set 
correctly to make the system work properly. 

STANDALONE Mode 

  To  know  the  2N

®

 SmartCOM  public  IP 

address, connect via the serial port using the 
Terminal Config program or use an SMS. 

  To  switch  the  command  mode  into  the  data 

mode,  use  the 

ato

  command,  or  enable 

Autoanswer  to  ensure  that  an  incoming 
external  call  switches  the  port  into  the 
transparent mode. 

  Connect the device to  be supervised to  one of 

the available serial ports  (RS232 or RS485 / M-
BUS).  

  Launch  the  Telnet  application    and  get 

connected  to  the  2N

®

 SmartCOM  public  IP 

address  via  TCP  port  10000  to  configure 
parameters as via a serial port. 

  Use  TCP  port  10001  for  data  retransmitting 

to RS232. 

  Use  TCP  port  10002  for  data  retransmitting 

to RS485.

 

 
2N

®

 SmartCOM SMS Configuration 

To know the default settings, send an SMS to the number of the SIM card inserted in 2N

®

 SmartCOM in the 

following format. The default password is 

password

. The terminal will send back an SMS with the 

required values. 
 

SC INFO PWD

=<password>

 

and

 SC CNF PWD

=<password> 

The SMS includes all basic parameters necessary for you to put 2N

®

 SmartCOM in operation. To change a 

parameter, send a configuration SMS in the format shown below. The PWD parameter is obligatory and 
the other parameters are arranged as necessary. Refer to the CD User Manual for more information. 
 

SC CNF PWD

=<password>

 MODE

=<mode> 

232LCK

=<rs232 lock>

 APN

=<new APN> 

 DUSR

=<new 

GPRS user name> 

DPWD

=<new GPRS password> 

IPS

=<new server IP address> 

PORTS

=<new 

server port number> 

NPWD

=<new password> 

 
The MODE and 232LCK parameters are entered in a digital form.  Mode 1 -TCP Client, 3 - Standalone. 
232LCK 1 - on, 0 - off. 
 

 
Declaration of Conformity 

2N  TELEKOMUNIKACE  a.s.  hereby  declares  that  the  2N

®

  SmartCOM  product  complies  with  all  basic 

requirements  and  other  relevant  provisions  of  the  1999/5/EC  directive.  For  the  full  wording  of  the 
Declaration of Conformity see www.2n.cz. 

1645v1.1.0 