![2N LiftNet Скачать руководство пользователя страница 63](http://html.mh-extra.com/html/2n/liftnet/liftnet_user-manual_439782063.webp)
Parameter Chart (FW v. 1.9.1)
3.2
63
Par.
No.
Parameter Name Range
Default
Note
977
Checking call
sequence
Up to 8
messages
(each has
2-digit ID)
blank
(=2829
1612)
22 = "Wait please, connection is being
established"
23 = "This is an emergency call"
24 = "Press 1 for connection with the lift cabin"
25 = " Press 1 for connection with the lift"
26 = Outgoing DISA ("Press 1 for connection
with the lift cabin. Press 2 to mute the
message. Press 3 to repeat the message. Press
5 to terminate the call.")
27 = "Connection confirmed"
28 = "This is a checking call"
29 = "This is communicator ..."
Cautions:
1)
User messages
#1
to
#10
are
recorded into the CU with the aid of
Service Tools
2)
""
= voice message
3)
DTMF sequence (2N protocol)
Format: *X*Y
Y*ID(par.974)*checksum#
X=1 - Alarm, 2 – Checking call
YY=00 – Checking call, SA – shaft +
audio unit ID (e.g. SA=11 means shaft
1 and cabin audio unit)
978
Sequence of
messages upon call
confirmation by
button 1
Up to 8
messages
(each has
2-digit ID)
blank
(=27)
979
Sequence of
messages for
dispatching upon
pressing of button 3
Up to 8
messages
(each has
2-digit ID)
blank
(=1612
171318
14)
981
Checking call
0 – 4
0
0 = off
1 = checking call in 1 minute
2 = on, first call in 2 hours
3 = on, first call in full period time
4 = on, checking call according to parameter
986 (Days in week)
CAUTION!
Each of the values switches on
periodic checking calls, the period is the same,
only the first call time is different.
982
Checking call interval
hhmmhhm
m
00002359
Allows to force a checking call e.g. at night
(lower fee).
983
Checking call period
0 – 100
days
3 days
0 = OFF (however, setting parameter 981 to 0
has the same effect).
984
Time adjustment
hhmmss
or hhmm
blank
Necessary if the Checking call interval is used
(can only be set via the voice menu;
synchronisation with the PC time is made via
the Service Tool).
985
Date adjustment
yymmdd
blank
Configure when parameter 986 is set to Days in
week (upon a date change, the test call date is
rescheduled according to the new date)
(can only be set via the voice menu;
synchronisation with the PC time is made via
Содержание LiftNet
Страница 1: ...2N LiftNet Lift Communicator User Manual Version 1 9 3 Firmware version 1 9 1 www 2n cz ...
Страница 3: ...2N LiftNet product is the holder of the Type certificate of the TÜV SÜD Czech company ...
Страница 10: ...Product Description 1 1 10 Figure 1 2 Example of CU and 2N LiftNet Local Dispatching Audio Unit Connection ...
Страница 11: ...Product Description 1 1 11 Figure 1 3 Example of Fireman Connection in 2N LiftNet ...
Страница 18: ......
Страница 54: ......
Страница 66: ......
Страница 82: ......
Страница 86: ...Battery Maintenance 5 1 86 ...
Страница 88: ......
Страница 89: ...89 6 6 Technical Parameters This section describes the technical parameters of the 2N LiftNet product ...
Страница 92: ......