1.8 Technical Parameters
Telephone Parameters
Value
Conditions
Minimum required off-hook line current
15 mA
Off-hook
Minimum required on-hook line voltage
20 V
Hang-up
DC voltage drop (off-hook)
< 8 V
< 16 V
I = 25 mA
I = 50 mA
Lead current while hang-up
< 25 μA
U = 60 V
Off-hook AC impedance
220 Ω + 820 Ω
115 nF parallel
20 to 60 mA
Return loss
> 10 dB
20 to 60 mA
Bandwidth
300 to 3500 Hz
20 to 60 mA
Ringing impedance
> 2 kΩ
C = 1 μF
25 to 50 Hz
Ringing detector sensitivity
10 to 20 V
25 to 50 Hz
Time of response to ringing
Variable
Pulse dialling
40 / 60 ms
20 to 60 mA
DTMF level
-6 and -8 dB
± 2 dB
20 to 60 mA
DTMF detector sensitivity
Min. -40 dB
20 to 60 mA
Dial tone detector sensitivity
Min. -40 dB
350 - 500 Hz
Busy tone detection speed
Variable
350 - 500 Hz
Continuous tone detection speed
Variable
350 - 500 Hz
Ringing tone detection speed
Variable
350 - 500 Hz
Overvoltage protection – common mode
1000 V
8 / 20 μs
Overvoltage protection – between A, B conductors
1000 V
8 / 20 μs
Other Electric Parameters
Switch – max. voltage
48 V AC, DC
Switch – min. voltage
9 V AC, DC
Switch – max. current
2 A AC, DC
Backlight – rated voltage
12 V
Backlight – max. voltage
14 V
Backlight – current consumption
Up to 5 mA