4.1  Technical Parameters 

Signalling protocol 

SIP (UDP) 

Buttons 

Button design 

Transparent, white backlit buttons with easily 
replaceable name tags 

Button count 

1 or 2 

Audio

 

Microphone 

1 integrated microphone 

Amplifier 

1W (class D) 

Loudspeaker 

1W  

Volume control 

Adjustable with automatic adaptive mode 

Full duplex 

Yes (AEC) 

Audio stream 

Protocols 

RTP/RTSP 

 

Codecs 

G.711 

 

Interfaces 

Power supply 

12V+-15%/1A DC or PoE 

PoE 

PoE 802.3af (Class 0 - 12.95W) 

LAN 

10/100BASE-TX s Auto-MDIX, RJ-45 

Recommended cabling  Cat-5e or higher 

Passive switch 

NO and NC contacts, up to 30V/1A AC/DC 

Active switch output 

12V/700mA DC 

Mechanical properties 

 

Cover 

ABS plastic, high-quality stainless steel 

 

Working temperature 

-40°C to 55°C  

 

Working relative 
humidity 

10% to 95% (non-condensing)

 

 

 

Storing temperature 

-40°C to 70°C 

 

Dimensions 

193 x 115 x 39 mm 
197 x 119 x 47 mm with flush mounting box 
193 x 115 x 57 mm for wall mounting 

 

Weight 

Product net weight....... 500 g 
Mounting box ....... 135 g 
Total weight incl. package ... 800 g 

 

Covering level 

IP54 

Содержание Helios IP Uni

Страница 1: ...2N Helios IP Uni Door Access Intercom Installation Manual Version 1 0 0 www 2n cz ...

Страница 2: ...E a s Any product and or other names mentioned herein are registered trademarks and or trademarks or brands protected by law 2N TELEKOMUNIKACE administers the FAQ database to help you quickly find information and to answer your questions about 2N products and services On faq 2n cz you can find information regarding products adjustment and instructions for optimum use and procedures What to do if D...

Страница 3: ...lation 13 2 1 Before You Start 14 Product Completeness Check 14 2 2 Mechanical Installation 15 Mountiong Type Overview 15 Common Mounting Principles 16 Flush Mounting Classic Bricks 17 Flush Mounting Plasterboard 18 Wall Mounting 18 Electric Installation 19 PCB Connectors 19 2 3 Button Tags Insertion and Replacement 21 Tag Printing 21 Tag Inserting Replacing vložit nový obr 21 3 Function and Use 2...

Страница 4: ...eters 27 4 1 Technical Parameters 29 5 Supplementary Information 30 5 1 Directives Laws and Regulations 31 5 2 Troubleshooting 32 5 3 General Instructions and Cautions 33 Electric Waste and Used Battery Pack Handling 34 ...

Страница 5: ...introduce the 2N Helios IP Uni product outline its application options and highlight the advantages following from its use Here is what you can find in this section Product Description Upgrade 2N Helios IP Uni Components and Associated Products ...

Страница 6: ... echo cancelling AEC system the product provides mutual audibility even of persons talking at the same time under normal conditions 2N Helios IP Uni can be provided with 1 or 2 pre programmed buttons You can set up to three telephone numbers and time profiles for each of the buttons to increase the accessibility of the called party 2N Helios IP Uni is equipped with an electric lock switch You can ...

Страница 7: ...r Bidirectional communication acoustic echo cancelling Optional dial buttons including name tags and backlight Integrated electronic lock switches with wide setting options LAN PoE or external 12V power supply Configuration via web interface or dedicated PC application SIP 2 0 support HTTP server for configuration SNTP client for time synchronisation with server ...

Страница 8: ...Upgrade 1 2 8 1 2 Upgrade The manufacturer reserves the right to modify the product in order to improve its qualities Version Changes ...

Страница 9: ...Associated Products Basic Units 9153101 9153102 2N Helios IP Uni is designed for outdoor applications and requires no additional roof All 2N Helios IP Uni units can be flush mounted without requiring any additional accessories Use the appropriate mounting box see below for wall surface mounting ...

Страница 10: ...ed Products 1 3 10 Mounting Accessories 9153003 Wall mounting box Al casting Brick flush mounting box included in the delivery GSM UMTS Connection Accessories 505004 2N VoiceBlue Lite 505214 2N VoiceBlue Enterprise 505612 2N UMTS Office Route ...

Страница 11: ...ephone 91378350 Grandstream VoIP video telephone Electric Locks 932070 BEFO 1211 12V 600 mA 932080 BEFO 1221 with momentary pin 932090 BEFO 1211MB with mechanical blocking Other Accessories 91341481E 12 V 2 A adapter A stabilised power supply must be used where PoE supply is not applied 932928E 12 V transformer 9137410E External IP relay ...

Страница 12: ...ls Safety Warning Always abide by this information to prevent injury of persons Warning Always abide by this information to prevent damage to the device Caution Important information for system functionality Tip Useful advice Note Additional information ...

Страница 13: ...allation In this section we describe the 2N Helios IP Uni product and its installation Here is what you can find in this section Before You Start Mechanical Installation Button Tags Insertion and Replacement Electric Installation ...

Страница 14: ...ur 2N Helios IP Uni delivery 1 2N Helios IP Uni selected model 1 Torx 10 Torx 20 double ended wrench 1 2N Helios IP Uni Installation Manual 1 mounting template 1 CD 1 A5 transparent name plate foil 1 spare name plate 1 brick flush mounting box 4 4x12 stainless steel torx screws for plastics 2 cable ties ...

Страница 15: ...ts Flush mounting classic bricks also hollow bricks thermally insulated walls etc What you need A properly cut hole Plaster mounting glue mounting foam or mortar as necessary Flush mounting plasterboard What you need Just a properly curt hole Wall mounting concrete and steel structures entry barrier columns etc What you need Wall mounting box Part No 9153003 ...

Страница 16: ...not met water might get in and destroy the electronics It is because the intercom circuits are under continuous voltage and water infiltration causes an electro chemical reaction The manufacturer s warranty shall be void for products damaged in this way Common Mounting Principles Tip Select flush mounting where possible to make your product elegant looking more vandal resistant and more secure Cau...

Страница 17: ...e front panel from the door intercom 5 Connect the cables to the terminals or RJ connector as described in the Electric Connection subsection 6 You can use the cable tie for connection as shown Suggested cable fixation Mounting completion after electric installation 7 Insert the intercom in the mounting box in the wall 8 Tighten the intercom with the stainless steel screws included in the delivery...

Страница 18: ... front panel from the door intercom 3 Connect the cables in the hole to the terminals or RJ connector as described in the Electric Connection subsection 4 You can use the cable tie for connection as shown on previous page Mounting completion after electric installation 5 Insert the intercom in the hole keeping it in the vertical position 6 Loosen the four clamp screws one after another and then re...

Страница 19: ...ct 2N Helios IP Uni into your Local Area Network LAN and how to connect supply voltage and the electric lock PCB Connectors Description of Connectors LAN LAN connector OUT1 12V 700 mA switched output RELAY1 Relay NO NC contacts TAMPER Tamper switch POWER 12V 1A DC power input RESET RESET button ...

Страница 20: ...e function of your device PoE Supply 2N Helios IP Uni is compatible with the PoE 802 3af Class 0 12 95W technology and can be supplied directly from the LAN via compatible network elements If your LAN in incompatible insert the PoE injector Part No 91758100E between 2N Helios IP Uni and the nearest network element Electric Lock Connection 2N Helios IP Uni is equipped with an electrically isolated ...

Страница 21: ...re easy to insert and replace even without a manual You need not remove the front panel and thus are not exposed to the risk of loss of components while replacing the tags 1 Loosen the name plate screw using the wrench enclosed for example You can open the name plate window like a door without losing the tightened screw 2 Remove the used or blank name tag and insert a new tag 3 Close the name plat...

Страница 22: ......

Страница 23: ...nction and Use In this section we describe the basic and extending functions of the 2N Helios IP Uni product Here is what you can find in this section 2N Helios IP Uni Configuration 2N Helios IP Uni Maintenance ...

Страница 24: ...figuration Manual for configuration details If your device remains inaccessible you have forgotten the IP address or the LAN configuration has changed for example change the LAN settings using the buttons on the device Static Dynamic Address Setting Mode Switching In case your 2N Helios IP Uni device is equipped with 1 or 2 buttons you can switch the modes using one button only Connect 2N Helios I...

Страница 25: ...to make quick dialling for the first 1 or 2 depending on the model type in the telephone directory Call setup is signalled by a long intermittent tone or otherwise as configured in the PBX connected Repeated pressing of one and the same speed dial button during call setup may initiate call termination or call termination plus dialling the next telephone number of the called subscriber or may be as...

Страница 26: ...porate quickly Future Tag Replacement Programming Changes For necessary steps refer to the preceding subsections Keep the following for future changes This manual Unused transparent foil strips for button tags Always use the product for the purpose it was designed and manufactured for in compliance herewith The manufacturer reserves the right to modify the product in order to improve its qualities...

Страница 27: ...27 4 4 Technical Parameters In this section we describe the technical parameters of the 2N Helios IP Uni product ...

Страница 28: ......

Страница 29: ...A DC or PoE PoE PoE 802 3af Class 0 12 95W LAN 10 100BASE TX s Auto MDIX RJ 45 Recommended cabling Cat 5e or higher Passive switch NO and NC contacts up to 30V 1A AC DC Active switch output 12V 700mA DC Mechanical properties Cover ABS plastic high quality stainless steel Working temperature 40 C to 55 C Working relative humidity 10 to 95 non condensing Storing temperature 40 C to 70 C Dimensions 1...

Страница 30: ...30 5 5 Supplementary Information This section provides supplementary information on the 2N Helios IP Uni product Here is what you can find in this section Applicable Directives Laws and Regulations ...

Страница 31: ...ary 2003 on the restriction of the use of certain hazardous substances in electrical and electronic equipment Regulation EC No 1907 2006 of the European Parliament and of the Council of 18 December 2006 concerning the Registration Evaluation Authorisation and Restriction of Chemicals REACH establishing a European Chemicals Agency amending Directive 1999 45 EC and repealing Council Regulation EEC N...

Страница 32: ...Troubleshooting 5 2 32 5 2 Troubleshooting For tips concerning solutions of other potential problems see faq 2n cz ...

Страница 33: ... a result of a natural disaster or any other unfavourable natural condition The manufacturer shall not be held liable for any damage of the product arising during the shipping thereof The manufacturer shall not make any warrant with regard to data loss or damage The manufacturer shall not be liable and responsible for any direct or indirect damage incurred as a result of a use of the product in co...

Страница 34: ... electric appliances and battery packs removed from them to dedicated dumpsites or containers or give them back to the dealer or manufacturer for environmental friendly disposal The dealer or manufacturer shall take the product back free of charge and without requiring another purchase Make sure that the devices to be disposed of are complete Do not throw battery packs into fire Battery packs may ...

Страница 35: ...2N TELEKOMUNIKACE a s Modřanská 621 143 01 Prague 4 Czech Republic Tel 420 261 301 500 Fax 420 261 301 599 E mail sales 2n cz Web www 2n cz DR1812v1 0 ...

Отзывы: