2N TELEKOMUNIKACE a.s., www.2n.cz
50/85
1.
2.
3.
4.
5.
6.
Factory Default Resetting (PCB version 555v3 and higher)
For resetting device to default settings press and hold SW1 button. Wait for the first
sound signalization and then release the button. If you press the button for short time
device will reboot only. SW1 button is available in devices with PCB version 555v3 and
higher. For devices with PCB version 555v3 see procedure below.
Caution
In case of resetting the factory default settings on a device with a
version of firmware 2.18 or higher it is necessary to reprogram the
using the instructions from section
2N IP Security Relay
®
Factory Default Resetting (PCB version 555v2)
Disconnect the device from the power supply.
Move the short-circuit jumper on connector X6 into the
position.
Default setup
Configuration jumpers (X6) are located in the right-hand upper corner of the
PCB.
Reconnect the power supply and wait for a start signalling sound.
Disconnect the device from the power supply.
Move the short-circuit jumper on connector X6 into the
Normal operation
position.
Reconnect the power supply. The device will be reset to factory default.
Содержание 01353-001
Страница 1: ...www 2n cz 2N IP Safety Emergency IP Intercom Installation Manual Version 2 13 ...
Страница 41: ...2N TELEKOMUNIKACE a s www 2n cz 41 85 2N IP Safety Connectors PCB Version 555v3 ...
Страница 44: ...2N TELEKOMUNIKACE a s www 2n cz 44 85 Wiring diagram for the controlled device s electric circuit opening ...
Страница 56: ...2N TELEKOMUNIKACE a s www 2n cz 56 85 OVP overvoltage protection ...
Страница 59: ...2N TELEKOMUNIKACE a s www 2n cz 59 85 Module settings Refer to the for details Configuration Manual ...
Страница 73: ...2N TELEKOMUNIKACE a s www 2n cz 73 85 3 3 Downloads Software 2N Network Scanner ...
Страница 77: ...2N TELEKOMUNIKACE a s www 2n cz 77 85 4 1 General drawings Surface mounting ...
Страница 78: ...2N TELEKOMUNIKACE a s www 2n cz 78 85 Flush mounting Plasterboard mounting Flush mounting with box ...