Operating Instructions GEMINI R Rotating Laser
6
Structure EN
Control panel of the IR remote control
Control panel of the laser receiver
The button symbols and functions correspond to
the comparable buttons on the control panel of the
GEMINI R, see page 13.
Exception:
13
"Send" LED display
Briefly lights up when buttons 4, 5 or 12 are
pressed.
Flashes as long as buttons 1, 2, 3 or 6 are
pressed.
1
"ON/OFF" button
Switches the receiver on and off.
2
"Acoustic signal" button
Switches the acoustic signal quied/loud .
3
"Detector field sensitivity" button
Switches the sensitivity between coarse/fine .
4
LCD display "Acoustic signal"
Lights up corresponding to "acoustic signal
quied/loud".
5
LCD display "Target"
Lights up if the laser line is located precisely at the
level of the zero line. In addition, a continuous tone
is emitted.
6
Detector field
7
"Coarse sensitivity" LCD display
Lights up if the sensitivity is set to "coarse".
8
"Fine sensitivity" LCD display
Lights up if the sensitivity is set to "fine".
9
LCD display "Lower"
Lights up if the laser line is within the sensor
window but below the zero line. A slow, intermittent
tone is also emitted.
10
LCD Display "Higher"
Lights up if the laser line is within the sensor
window but above the zero line. A rapid,
intermittent tone is emitted.
11
LED display "Battery"
Indicates the battery's state of charge.