background image

6

 

General Functions Overview 
 
1. TRIG: 

Trigger input 
 
A stream of trigger signals will emit from 

OUT

 when a trigger or gate signal is received 

at the 

TRIG 

input 

 

 

Threshold: 2.5V 

 
 
2. PULSES CV: 

Control voltage input for 

PULSES 

 

Control voltage is added to the knob position 

 

Range: 0V 

– 5V 

 
 
3. PULSES: 

Controls the number of pulses that output when a trigger or gate signal is received by 
the 

TRIG 

input 

 
If the knob is far left, the number of pulses will be set to 1 
If the knob is far right, the number of pulses will be set to 32 

 

 

4. RATE CV: 

Control voltage input for 

RATE 

 

Control voltage is added to the knob position 
 
Range: 0V 

– 5V 

 
 
5. RATE: 

Controls the delay time in between successive pulses 
 
If the knob is far left, the delay time in between successive pulses will be set to 10ms 
If the knob is far right, the delay time in between successive pulses will be set to 
500ms 

 
 

Содержание Brst

Страница 1: ...Brst ...

Страница 2: ...r control over speed and the number of repetitions Whether you re generating bouncing balls crafting IDM drum beats or humanizing a clock signal Brst will prove an indispensable addition to your rack Voltage controlled burst generator CV over number of pulses and rate of output Initial trigger can be included or omitted from output Wide burst range all the way up to 32 repeats ...

Страница 3: ...3 Table of Contents Installation Specifications 4 Brst 5 General Functions Overview 6 ...

Страница 4: ...ctor into the power distribution board of your case keeping in mind that the red band corresponds to negative 12 volts In most systems the negative 12 volt supply line is at the bottom The power cable should be connected to the Brst with the red band facing the front of the module Specifications Format 2 HP Eurorack module Depth 47mm Skiff Friendly Max Current 12V 26mA 12V 7mA ...

Страница 5: ...5 1 2 3 4 5 6 7 8 ...

Страница 6: ...ut when a trigger or gate signal is received by the TRIG input If the knob is far left the number of pulses will be set to 1 If the knob is far right the number of pulses will be set to 32 4 RATE CV Control voltage input for RATE Control voltage is added to the knob position Range 0V 5V 5 RATE Controls the delay time in between successive pulses If the knob is far left the delay time in between su...

Страница 7: ...ignal will be included If the toggle is right the initial trigger signal will be omitted It important to note that if the TRIG TOGGLE is right and the PULSES knob is set to 1 one pulse will emit from OUT and will be delayed by 10ms 7 BURST LED LED that indicates the pulses emitted from OUT 8 OUT Burst output Range 0V 5V ...

Отзывы: