Shock/Door/Window Contact |  Installation Instructions

Inserting and Replacing the Batteries

To insert or replace the batteries:

Press in the Retaining Tab (A) and gently swing the top of the 

sensor up and off the base.

Place a small non-metal object in the slot on the side of the sensor 

(see Part C,D in Figure 2, Shock / Door / Window Contact and 

Battery Compartment)

.

Carefully push the battery out through the Battery Access slot.

WARNING:

 Failure to follow these warnings and instructions can lead 

to heat generation, rupture, leakage, explosion, fire, or other injury, or 

damage. Do not insert the battery into the compartment in the wrong 

direction. Always replace the battery with the same or equivalent type. 

Never recharge or disassemble the battery. Never place the battery in 

fire or water. Always keep batteries away from small children. If batter

-

ies are swallowed, promptly see a doctor. 

Restore Factory Settings

Press and hold the program button for more than 10 seconds:

● Release the program button after the Orange LED flashes three times.
● Press and release the program button once more to confirm that

factory defaults are to be restored. If this is not done within 5

seconds, the reset function will be terminated with no change to the

programmed settings.

The Red LED will flash as per the programmed shock sensor setting then 

the Green LED will flash per the programmed Magnet Detection setting.

Tilt the cover to align tab C through slot D.

Close the cover down, and press down until tab A snaps into slot B.

Finalizing the Installation

A

B

D

C

Figure 4. Replacing Sensor Cover

A

No

n-Met

al O

bje

ct

Figure 5. Remove/Replace Battery

Installer Test Mode

To enter Installer Test Mode, remove the top housing from the sensor. 

In this mode the LED will blink to indicate specific conditions.

IMPORTANT:

 Always dispose and/or recycle used batteries in 

accordance with the hazardous waste recovery and recycling 

regulations for your location. Your city, state, or country may also 

require you to comply with additional handling, recycling, and disposal 

requirements.

Insert the replacement battery in the compartment. The positive (+) 

sign on the battery should be facing down and the negative (–) side 

facing up.

The Green LED will illuminate for 2 seconds as the Device powers up.

Replace the top case 

(see Finalizing the Installation, above)

.

Event

LED Color

Duration

Shock Detected

Red

ON for 8 seconds

Magnetic Detection

Green

Single Blink

Magnetic Tamper

Orange

Single Blink

Magnetic Calibration Required Red

Double Blink

Shock Detection System Test - Glass Mounted

Firmly tap the glass twice with a hard plastic object (screwdriver 

handle) within 12 inches of the sensor.  Verify that the shock event 

was received by the panel.  It may take up to 2 seconds for the panel 

to receive the notification.

NOTE:

  Do not strike the surface hard enough to break the glass.

Calibrating Magnet Detection

When magnetic detection is first enabled, the RED LED will 

blink to indicate that it is not calibrated. THE SENSOR MAGNET 

CALIBRATION MUST BE COMPLETED TO OPERATE PROPERLY. 

IF NOT CALIBRATED THE SENSOR WILL NOT TRANSMIT OPEN/

CLOSE INFORMATION TO THE CONTROL PANEL. 
To calibrate the sensor:

Mount the sensor and magnet in it’s final location as instructed 

earlier in this document.

Close the door or window.

Press the Program button.

LED will start blinking ORANGE.

Open the door or window completely.

Press the Program button again.

LED will start blinking green

Fully close door or window and press the Program Button within 

10 seconds to complete the calibration process..

LED will illuminate green for 2 seconds and then turn off and the 

calibration is complete.

NOTE: 

If Magnet Detection is turned off then back on or if the battery 

is removed or replaced, the sensor will lose the Magnet Calibration 

setting and will have to be re-calibrated. 

Содержание 2GIG-SHKDW1-345

Страница 1: ...test transmission to verify that it can establish good Radio Frequency RF communications with the control panel NOTE To learn how to program and fully test the Shock Door Window Contact Sensor see the control panel s Installation and Programming Guide For 2GIG panels using older irmware this sensor may be learned in as a D W device Newer panel firmwares will support shock detector equipment code t...

Страница 2: ...ium sensitivity setting Three button presses selects the high sensitivity setting Four button presses selects the very high sensitivity setting Five button presses selects the glass mount setting Default Each time the button is pressed the Red LED will illuminate until the button is released NOTE If the button is pressed six or more times such entries will be ignored and the LED will remain off an...

Страница 3: ...and or recycle used batteries in accordance with the hazardous waste recovery and recycling regulations for your location Your city state or country may also require you to comply with additional handling recycling and disposal requirements 1 Insert the replacement battery in the compartment The positive sign on the battery should be facing down and the negative side facing up 2 The Green LED will...

Страница 4: ... Canadian ICES 003 Cet appareil numérique de la classe B est conforme à la norme NMB 003 du Canada This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radi...

Отзывы: