![2gig Technologies 2GIG-NTRL2 Скачать руководство пользователя страница 18](http://html.mh-extra.com/html/2gig-technologies/2gig-ntrl2/2gig-ntrl2_installation-and-programming-instructions_439608018.webp)
16
Each system installed will require programming. Most installations
being performed by the professional alarm installer for a specifi c
organization will have common values set in every Control Panel
reporting to the same Central Station. Other programming values,
such as the account number and sensor setup, will be unique for
each installation.
Following is an outline to guide the professional alarm installer
through the programming of the Control Panel.
If you don’t read anything else, read this outline!
Use the following outline in conjunction with this copy of the
Installation and Programming Instructions to guide you through
the installation.
Because of the many programming options available with this
Control Panel, thoroughly reading this manual is very important.
Understanding the Control Panel’s programming structure will help
to save time during each installation.
At this stage, all the wireless and hardwired sensors should be
installed, and the Control Panel should be mounted, connected,
and powered-up.
1.
Start at the Home Screen.
2.
Press the logo at the lower right corner of the screen.
(The Installer Toolbox can also be accessed via
the third screen of the System Toolbox.)
3.
Enter the Installer Code (default = 1561) to display the Installer Toolbox.
4.
Press
SYSTEM CONFI
G
URATION
and begin
programming as described on Page 18.
5.
USE THE INSTALLATION LO
G
SHEET TO RECORD
PRO
G
RAMMED VALUES FOR THE SYSTEM.
6.
After setting all the required programming values for the sensors and
the Control Panel, press
END
, then
EXIT
, to save the changes.
7.
After the Control Panel restarts, press
SECURITY
,
MENU
,
TOOL
B
OX
, enter the Master User Code (default = 1111), press
USER MANA
G
EMENT
and setup the user’s codes. Be sure to
set a Duress Code as User #8. Press
B
ACK
when fi nished.
8.
Press
B
RI
G
HTNESS / VOLUME
and set the levels for the installation.
The volume setting DOES NOT affect the volume of alarm sounds.
9.
Press
➜
to view the second toolbox screen.
10.
Press
B
ACKLI
G
HT TIMEOUT
and set the display lighting timeout.
11.
Press
SET DATE
and
SET TIME
and set the calendar and clock. (If the
GSM module is installed, the date and time are set automatically.)
12.
Press the
button to return to the Home Screen.
After all setup and programming, refer to the Operation and
User’s Guide for details on operating the system.
Check off the
programmed options for the system in the User’s Guide.
Be sure to instruct the subscriber on the proper operation of the
system, and leave the User’s Guide at the installation site for
reference.
SIA CP-01 Defaults
Several system programmable options have the defaults pre-set to
provide compliance with the Security Industry Association CP-01
Standard. All other system settings and functions that are required
to comply with SIA CP-01 are permanently programmed into
the Console and cannot be changed. Refer to the table for each
programmable option that has a required SIA CP-01 programming
default.
Programming Outline
Figure 47. Installer Toolbox Screen
Figure 48. System Confi guration Question “Q-1”
PRO
G
RAMMIN
G
QUESTION
SIA CP-01 DEFAULT
RAN
G
E
Q-1 Wireless Sensor Dialer Delay
30 Seconds
On or Off
Q-2 Wired Sensor Dialer Delay
30 Seconds
On or Off
Q-5 Exit Delay
60 Seconds
45-120 Seconds
Q-6 Entry Delay #1
30 Seconds
30-240 Seconds
Q-7 Entry Delay #2
45 Seconds
30-240 Seconds
Q-10 Call Waiting Disable Code
No Default Code
0-6 Digits
Q-20 Swinger Shutdown Count
2 Trips
1-6 Trips
Q-26 Auto Stay
Enabled
Enabled or Disabled
Q-27 Exit Delay Restart
Enabled
Enabled or Disabled
Q-31 Cancel Time
5 Minutes
6-254 Minutes
Q-32 Cancel Display
Enabled
Enabled or Disabled
Q-35 Abort Window Dialer Delay
30 Seconds
15 or 45 Seconds
Q-78 Select Output
Follows Internal Sounder
See Q-78 for Options
Figure 45. The Home Screen
P
r
e
ss
lo
g
o to
a
cce
ss
the I
ns
t
a
lle
r
Tool
b
ox
Figure 46. Toolbox Screen Three
I
ns
t
a
lle
r
Tool
b
ox c
an
b
e
a
cce
ss
e
d
he
r
e
a
l
s
o
Содержание 2GIG-NTRL2
Страница 1: ...Wireless Security System Installation Programming Instructions 2GIG CNTRL2 2GIG CP2 ...
Страница 48: ...46 Notes ...
Страница 49: ...47 Notes ...
Страница 52: ...v1 9 233497 E Copyright 2012 ...