 2GIG-FT1-345

FLOOD AND TEMPERATURE DETECTOR

INSTALLATION INSTRUCTIONS

The 2GIG-FT1-345 is a fully supervised, tamper protected one-way 345 MHz 
sensor. It will monitor the ambient temperature and/or will detect a wet/dry 

fl

 ood 

condi  on. The sensor reports wet/dry condi  ons and temperature to the panel.

Flood Conditions

Once the sensor probe detects the presence of water for three (3) minutes, the 
integral transmi   er will send a wet alarm transmission to the panel. The probe will 
also send a restore (dry) report when the presence of liquid is no longer detected 
by the 

fl

 ood probe for three (3) minutes. For 

fl

 ood repor  ng the sensor requires 

the installa  on of the supplied external 

fl

 ood probe. The sensor is capable of 

detec  ng clean or dirty fresh water, salt water, or tap water.

Temperature Conditions

Heat:

1.  If the temperature is more than 95° F (35°C) for 

fi

 ve (5) minutes, the sensor 

will send a loop 2 transmission.

2.  If the temperature is less than 95°F (35°C) for 

fi

 ve (5) minutes, the sensor will 

send a loop 2 clear.

Cold:

1.  If the temperature is less than 41°F (5°C) for 

fi

 ve (5) minutes, the sensor will 

send a loop 3 transmission.

2.  In the temperature is more than 41°F (5°C) for 

fi

 ve (5) minutes, the sensor 

will send a loop 3 clear.

Contents

Verify that the package includes the following:

• 1—2GIG Flood/Temperature Sensor
• 1—Sensor Mounting Plate
• 1—3V Lithium Battery ( Panasonic CR15H270 uninstalled)
• 3—3/8” Phillips Screws 
• 1—Double Stick Tape Strip
• 1—Probe Mounting Plate

Installation Tools Required

• Phillips  Screwdriver

Figure 1.

Temperature/Flood

 

Sensor Contents 

A

 Double 

S  ck Tape Strip

B

 Sensor 

Moun  ng Plate

C

 Probe 

Moun  ng Plate

D

  3V Lithium Ba  ery

E

  Phillips Screws (3/8”)

F

  Flood Probe Cord 

G

 Flood 

Probe

H

 Transmi  er with Integral Temperature Sensor

Installing and Replacing Battery

Open Sensor Case as show in Figures 2 and 3. 
Install or replace ba  ery.

Figure 2. 

Opening Sensor Case

Grip the base of the sensor case. Place thumb on tab and push down un  l sensor
case separates.

Figure 3. 

Separate Sensor Case

Figure 4. 

Installing New Ba  ery

Installing a New Battery and System Programming

NOTE: 

Do not install ba  ery un  l panel is in Sensor Programming Mode.

1.  Place panel in Sensor Programming mode 
2. Insert 

ba  ery

3. Close 

sensor

Replacement Battery Installation:

NOTE: 

If ba  ery has been previously installed

1. Remove 

ba  ery and dispose of (mee  ng state regula  ons)

2.  Wait two (2) seconds
3. Replace 

ba  ery

4. Close 

sensor

Installing/Mounting Flood/Temperature Sensor

The 2GIG-FT1-345 Flood and Temperature Sensor includes two methods of 
installa  on:

1. Double 

S  ck Tape Installa  on (See Figure 5).

2. Screw/Moun  ng Plate Installa  on (See Figure 6).

It is strongly recommended that the Flood/Temperature Sensor be mounted using 
screws (provided) and Moun  ng Plate (provided).

Figure 5. 

Double S  ck Tape Moun  ng Sensor Moun  ng Plate

A

B

C

D

E

F

G

H

1. PUSH DOWN ON
    THUMB TAB.

2. PULL BACK PLATE
    OFF OF COVER

BATTERY REMOVAL
AND/OR INSTALLATION

BATTERY

TEMPERATURE/
FLOOD SENSOR
BASE

REMOVE SENSOR
COVER FROM 
SENSOR BASE

MOUNTING 
PLATE

DOUBLE
STICK 
TAPE
STRIP

FLOOD/
TEMPERATURE
SENSOR

 

FIRST

PUSH
SENSOR
ONTO
MOUNTING
PLATE
TABS
  

 

THEN 

PUSH

UP

APPLY DOUBLE STICK
TAPE TO BACK OF
MOUNTING PLATE

WALL