manualshive.com logo in svg
background image

Battery Installation & Replacement

WARNING! The polarity of the battery must be observed, as shown (see Figure 3). Improper handling of lithium 

batteries may result In heat generation, explosion or fire, resulting personal injuries. Replace only with the same 

or equivalent type of battery as recommended by the manufacturer (see Specifications).
Batteries must not be recharged, disassembled or disposed of in fire.

 Disposal of used batteries must be made In 

accordance with the waste recovery and recycling regulations In your area.

Keep away from small children. If batteries are swallowed, promptly seek medical attention.

California Only:

 This Perchlorate warning applies only to Manganese Dioxide Lithium cells sold or distributed ONLY In 

California, USA. Perchlorate Material-special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate.

Specifications

Wireless Signal Range

Code Outputs

Supervisory

Transmitter Frequency

Transmitter Frequency Tolerance

Transmitter Bandwidth

Modulation Type

Unique ID Codes

Supervisory Interval

External Input Sampling Current

External Input

Sensor Dimensions (HxD)

Weight (Including battery & magnet)

Housing Material

Color

Operating Temperature

Relative Humidity

Battery (Installed with pull tab)

Regulatory Listing(s)

Warranty*

Included Accessories

350 ft, open air, with 2GIG Wireless Alarm Control Panel

Alarm Restore; External Alarm; External Restore

Low Battery

345.000 MHz (crystal controlled)

± 15kHz

24kHz

Amplitude Shift Keying-On/Off Keying (ASK-OOK)

Over one (1) million different code combinations

70 minutes

20 uA

24V AC Standard doorbell circuit

2.75 X 1.17 X 0.63 in. (6.98 X 2.97X 1.60 cm)

1.1 oz. (31.2 g)

ABS plastic

White

32° to 120°F (0° tO 49°C)

5-95% Non-Condensing

One (1) Panasonic CR2032, or equivalent Lithium batteries

FCC Part 15, Industry Canada

Two (2) years

Two (2) Phillip's flat-head screws

Technical Support:

1-866-670-1591

www.2gig.com

PN 77-000004-001 Rev B

To remove the sensor cover, use your finger to press the tab on the end of the case. This will disengage the clip holding 

the cover to the base.

Place a small flathead screwdriver in the slot between the metal clip (see Figure 3) and the battery and push it out taking 

care not to scratch the battery terminal on the PCB.

Insert the replacement battery with the + sign facing out (see Figure 3)

Verify programming and RF communication with the panel (see Testing).

1

2

3

4

If a sensor battery is low, a low battery notification will be indicated on the 2GIG Alarm Control Panel's screen. When the 

2GIG alarm system Indicates that there is a sensor with a low battery, replace the battery immediately. Use only the 

recommended replacement batteries (see Specifications).

To install or replace the battery, do the following:

©

2011 2gig Technologies Inc. All Rights Reserved

FCC & INDUSTRY CANADA REGULATORY INFORMATION

NOTICE: Unauthorized changes or modifications could void the user’s authority to operate the equipment.

This device complies with Part 15 of the FCC Rules and Industry Canada licence-exempt RSS standard(s). Operation is 

subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must 

accept any interference received, including interference that may cause undesired operation of the device.

Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. 

L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) 

l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en 

compromettre le fonctionnement.

This equipment has been tested and found to comply with the limits for a Class B computing device, pursuant to Part 15 of 

FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential 

installation. This equipment generates uses and can radiate radio frequency energy and if not installed and used in 

accordance with the instructions, may cause harmful interference to radio communications. However, there is no 

guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to 

radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try 

to correct the interference by one or more of the following measures:

     Reorient or relocate the receiving antenna.

     Increase the separation between the equipment and the receiver

     Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

     Consult the dealer or an experienced radio/television technician for help

.

.

.

.

FCC ID: WDQ-DBELL1345

Industry Canada ID: 7794A-DBELL1345

Отзывы: