In the program state, press and 

hold "CAM1" button for 3 seconds 

to switch the working mode. Then 

it will return to standby

   Working mode           indicator:CAM(1~4)

  

(flash once)

-6-

2).Working mode configuration, the camera switching time setting, and 

monitoring time setting.

In the standby, press and hold 

"CAM4" button for 3 seconds, it will 

enter the state of program.

indicator:IN-USE  

(flash)

[SCU mode]    [DCU mode]:

[DCU mode]    [SCU mode]:

(flash twice)

In the program state, press 

and hold "CAM2" button for 3 

seconds, it will enter the state of 

camera switching time setting.

(1)the left light of indicator CAM (1 ~ 4) 

starts flashing (flash once per second); 

(2)Flash once to increase 3 seconds;

(3)Press any button to confirm the 

setting and return to standby.

Note:
1. The maximum can be set to 
99 seconds, to 99 seconds, then 
automatically save and return to standby.
2. 6 seconds by default.

In the program state, press 

and hold "CAM3" button for 3 

seconds, it will enter the state of 

monitoring time setting.

(1)the right light of indicator CAM (1 ~ 4) 

starts flashing (flash once per second); 

(2)Flash once to increase 15 seconds;

(3)Press any button to confirm the 

setting and return to standby.

Note:
1. The maximum can be set to 900 
seconds, to 900 seconds, then 
automatically save and return to standby.
2. 600 seconds by default.

Note:In program state, if there isn’t any operation within 10s, or press any button, it will 
return to standby.

Содержание DT-SCU

Страница 1: ...ly before using the product you purchase and keep it well for future use We reserve the right to modify the specification in this manual at any time without notice 2 Wire System Power In Use Camera Interface Model SCU CAM 1 4 CAM1 CAM2 CAM3 CAM4 User Manual ...

Страница 2: ...m3 2 Wire Camera Input Cam4 Black video Ground Black 0V Red 12vdc Yellow video v2 Black video Ground Black 0V Red 12vdc Yellow video v1 Black video Ground Black 0V Red 12vdc Yellow video v2 Black video Ground Black 0V Red 12vdc Bus In Bus Out Cam3 2 Wire Camera Input Cam4 1 The camera interface DT SCU is a controller function device designed for DT system to control camera In addition DT SCU can b...

Страница 3: ... side of circuit ONLY BUS OUT Connect to the bus line no polarity on bus pair Connect to Door Station side of circuit ONLY BUTTONS Press CAM1 CAM4 button it can control the corresponding video output 2 INDICATORS 1 Power Working indicator always on when the SCU work normally 2 In Use Video output indicator always on when the SCU output the video 3 CAM 1 4 Video output indicator In Use CAM 1 4 Desc...

Страница 4: ...en the system connected SC6V and SC6V connected two cameras the two cameras of the device is valid it should be set to ON TYPE A Camera used When DT SCU connected TYPE A Camera it should be set to ON TYPE B Camera used When DT SCU connected TYPE B Camera it should be set to ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON set to the second DT SCU set to the third DT SCU set to the fourth DT SCU Whe...

Страница 5: ... IM BUS DS PC6 AC BUS IN BUS OUT SCU 1 2 3 4 5 6 ON 1 CCTV 2 CCTV DT CCU Camera BUS GND VIDEO BUS BUS 2 WIRE SYSTEM GND VEDIO DT CCU Camera BUS GND VIDEO BUS BUS 2 WIRE SYSTEM GND VEDIO 3 CCTV 4 CCTV 4 Wiring Diagram ...

Страница 6: ...ition Bit state Function Descriptions Bit 1 and bit 2 SCU DCU code setting Invalid for SCU DCU Set to the first SCU DCU Set to the second SCU DCU Set to the third SCU DCU Bit 3 and bit 6 Camera Config Bit 3 ON CAMERA1 Enable Bit 3 OFF CAMERA1 Disable Bit 4 ON CAMERA2 Enable Bit 4 OFF CAMERA2 Disable Bit 5 ON CAMERA3 Enable Bit 5 OFF CAMERA3 Disable Bit 6 ON CAMERA4 Enable Bit 6 OFF CAMERA4 Disable...

Страница 7: ...lashing flash once per second 2 Flash once to increase 3 seconds 3 Press any button to confirm the setting and return to standby Note 1 The maximum can be set to 99 seconds to 99 seconds then automatically save and return to standby 2 6 seconds by default In the program state press and hold CAM3 button for 3 seconds it will enter the state of monitoring time setting 1 the right light of indicator ...

Страница 8: ...king Temperature 150 C 550 C Wiring 2 wire non polarity Dimension 90 H 72 W 60 D mm The design and specifications can be changed without notice to the user Right to interpret and copyright of this manual are preserved DT ENG SCU V1 20161115 ...