background image

DT-QSW

CCTV 

Camera Interface

 

Please read this manual carefully before using the product you 

purchase

d

,  and  keep  it  for  future  use.

 

We  reserve  the  right  to 

modify specification in this manual at any time without notice

2-Wire System

 Power      In-Use

Camera Interface

Model: QSW

 CAM(1~4)

CAM1

CAM2

CAM3

CAM4

User Manual

Содержание DT-QSW

Страница 1: ...arefully before using the product you purchased and keep it for future use We reserve the right to modify specification in this manual at any time without notice 2 Wire System Power In Use Camera Interface Model QSW CAM 1 4 CAM1 CAM2 CAM3 CAM4 User Manual ...

Страница 2: ...ks as quad splitter with Aura and Alecto monitors Works with Avro and Leda monitors but not in a quad mode Each CCTV camera connected will be accessable via individual icon Maximum 1 x DT QSW Interface with maximum 4 x CCTV cameras for video monitors model Avro and Leda Maximum 4 x DT QSW Interfaces with maximum 16 x CCTV cameras for video monitors model Aura and Alecto 1 About DT QSW CCTV Interfa...

Страница 3: ...dicator flashes when quad video output BUTTONS used for testing mainly 1 Press CAM1 button in monitoring state the system will mandatory output the video of CAMERA 1 2 Press CAM2 button in monitoring state the system will mandatory output the video of CAMERA 2 3 Press CAM3 button in monitoring state the system will mandatory output the video of CAMERA 3 4 Press CAM4 button in monitoring state the ...

Страница 4: ...at the fourth camera available 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON DIP switches configuration for second DT QSW DIP switches configuration for third DT QSW DIP switches configuration for fourth DT QSW When set to OFF it means that the system select video split display mode A for details see section NOTE below Allways OFF When set to ON it means that the system select video split display m...

Страница 5: ... 4 3 Unit Mounting Din rail Din rail Mounting Buckle Step1 Mount din rail onto the wall with screws Step2 Pull down the mounting buckle and hang the unit on the din rail ...

Страница 6: ... 5 RF CARD BUS IM BUS DS PC6 AC BUS OUT BUS IN QSW 1 Camera 2 Camera 4 Camera 3 Camera 1 2 3 4 5 6 N O 4 Wiring Diagram 4 1 Single Door Station and single QSW application ...

Страница 7: ... application RF CARD BUS IM BUS DS PC6 AC BUS OUT BUS IN QSW DBC 4A A B C D RF CARD Device Address 1 Device Address 0 QSW a b 1 Camera 2 Camera 4 Camera 3 Camera 5 Camera 6 Camera 8 Camera 7 Camera 1 2 3 4 5 6 ON BUS OUT BUS IN 1 2 3 4 5 6 ON ...

Страница 8: ...ng Temperature 150 C 550 C Wiring 2 wire no polarity Dimensions H90 W72 D60mm The design and specifications can be changed without notice to the user Right to interpret and copyright of this manual are preserved www intelligenthomeonline com ...

Отзывы: